Last modified by Xiaoling on 2025/04/23 15:57

From version 40.42
edited by Xiaoling
on 2022/06/06 10:12
Change comment: There is no comment for this version
To version 40.43
edited by Xiaoling
on 2022/06/06 10:21
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -282,29 +282,29 @@
282 282  RS485-BL default UART settings is **9600, no parity, stop bit 1**. If the sensor has a different settings, user can change the RS485-BL setting to match.
283 283  )))
284 284  
285 -(% border="1" style="background-color:#ffffcc; color:green; width:510px" %)
286 -|=(% style="width: 121px;" %)(((
285 +(% border="1" cellspacing="190" style="background-color:#ffffcc; color:green; width:510px" %)
286 +|=(% style="width: 125px;" %)(((
287 287  (((
288 288  **AT Commands**
289 289  )))
290 -)))|=(% style="width: 114px;" %)(((
290 +)))|=(% style="width: 110px;" %)(((
291 291  (((
292 292  **Description**
293 293  )))
294 -)))|=(% style="width: 226px;" %)(((
294 +)))|=(% style="width: 255px;" %)(((
295 295  (((
296 296  **Example**
297 297  )))
298 298  )))
299 -|(% style="width:121px" %)(((
299 +|(% style="width:125px" %)(((
300 300  (((
301 301  AT+BAUDR
302 302  )))
303 -)))|(% style="width:114px" %)(((
303 +)))|(% style="width:110px" %)(((
304 304  (((
305 305  Set the baud rate (for RS485 connection). Default Value is: 9600.
306 306  )))
307 -)))|(% style="width:226px" %)(((
307 +)))|(% style="width:255px" %)(((
308 308  (((
309 309  (((
310 310  AT+BAUDR=9600
... ... @@ -317,11 +317,11 @@
317 317  )))
318 318  )))
319 319  )))
320 -|(% style="width:121px" %)(((
320 +|(% style="width:125px" %)(((
321 321  (((
322 322  AT+PARITY
323 323  )))
324 -)))|(% style="width:114px" %)(((
324 +)))|(% style="width:110px" %)(((
325 325  (((
326 326  (((
327 327  Set UART parity (for RS485 connection)
... ... @@ -333,7 +333,7 @@
333 333  Default Value is: no parity.
334 334  )))
335 335  )))
336 -)))|(% style="width:226px" %)(((
336 +)))|(% style="width:255px" %)(((
337 337  (((
338 338  (((
339 339  AT+PARITY=0
... ... @@ -346,11 +346,11 @@
346 346  )))
347 347  )))
348 348  )))
349 -|(% style="width:121px" %)(((
349 +|(% style="width:125px" %)(((
350 350  (((
351 351  AT+STOPBIT
352 352  )))
353 -)))|(% style="width:114px" %)(((
353 +)))|(% style="width:110px" %)(((
354 354  (((
355 355  (((
356 356  Set serial stopbit (for RS485 connection)
... ... @@ -362,7 +362,7 @@
362 362  Default Value is: 1bit.
363 363  )))
364 364  )))
365 -)))|(% style="width:226px" %)(((
365 +)))|(% style="width:255px" %)(((
366 366  (((
367 367  (((
368 368  AT+STOPBIT=0 for 1bit
... ... @@ -382,7 +382,6 @@
382 382  )))
383 383  )))
384 384  
385 -
386 386  === 3.3.2 Configure sensors ===
387 387  
388 388  (((
... ... @@ -1396,7 +1396,6 @@
1396 1396  * (% style="color:blue" %)**RU864**(%%): frequency bands RU864
1397 1397  * (% style="color:blue" %)**KZ865**(%%): frequency bands KZ865
1398 1398  
1399 -
1400 1400  = 9. Packing Info =
1401 1401  
1402 1402  (((