Last modified by Xiaoling on 2025/04/23 15:57

From version 40.35
edited by Xiaoling
on 2022/06/06 09:56
Change comment: There is no comment for this version
To version 40.41
edited by Xiaoling
on 2022/06/06 10:10
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -94,7 +94,6 @@
94 94  * 127 dB Dynamic Range RSSI.
95 95  * Automatic RF Sense and CAD with ultra-fast AFC. ​​​
96 96  
97 -
98 98  == 1.3 Features ==
99 99  
100 100  * LoRaWAN Class A & Class C protocol (default Class A)
... ... @@ -106,7 +106,6 @@
106 106  * Support Modbus protocol
107 107  * Support Interrupt uplink
108 108  
109 -
110 110  == 1.4 Applications ==
111 111  
112 112  * Smart Buildings & Home Automation
... ... @@ -116,7 +116,6 @@
116 116  * Smart Cities
117 117  * Smart Factory
118 118  
119 -
120 120  == 1.5 Firmware Change log ==
121 121  
122 122  [[RS485-BL Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/RS485-BL/Firmware/||style="background-color: rgb(255, 255, 255);"]]
... ... @@ -285,29 +285,29 @@
285 285  RS485-BL default UART settings is **9600, no parity, stop bit 1**. If the sensor has a different settings, user can change the RS485-BL setting to match.
286 286  )))
287 287  
288 -(% border="1" style="background-color:#ffffcc; color:green; width:795px" %)
289 -|(((
285 +(% border="1" style="background-color:#ffffcc; color:green; width:510px" %)
286 +|=(% style="width: 110px;" %)(((
290 290  (((
291 291  **AT Commands**
292 292  )))
293 -)))|(% style="width:285px" %)(((
290 +)))|=(% style="width: 200px;" %)(((
294 294  (((
295 295  **Description**
296 296  )))
297 -)))|(% style="width:347px" %)(((
294 +)))|=(% style="width: 200px;" %)(((
298 298  (((
299 299  **Example**
300 300  )))
301 301  )))
302 -|(((
299 +|(% style="width:110px" %)(((
303 303  (((
304 304  AT+BAUDR
305 305  )))
306 -)))|(% style="width:285px" %)(((
303 +)))|(% style="width:200px" %)(((
307 307  (((
308 308  Set the baud rate (for RS485 connection). Default Value is: 9600.
309 309  )))
310 -)))|(% style="width:347px" %)(((
307 +)))|(% style="width:200px" %)(((
311 311  (((
312 312  (((
313 313  AT+BAUDR=9600
... ... @@ -320,11 +320,11 @@
320 320  )))
321 321  )))
322 322  )))
323 -|(((
320 +|(% style="width:110px" %)(((
324 324  (((
325 325  AT+PARITY
326 326  )))
327 -)))|(% style="width:285px" %)(((
324 +)))|(% style="width:200px" %)(((
328 328  (((
329 329  (((
330 330  Set UART parity (for RS485 connection)
... ... @@ -336,7 +336,7 @@
336 336  Default Value is: no parity.
337 337  )))
338 338  )))
339 -)))|(% style="width:347px" %)(((
336 +)))|(% style="width:200px" %)(((
340 340  (((
341 341  (((
342 342  AT+PARITY=0
... ... @@ -349,11 +349,11 @@
349 349  )))
350 350  )))
351 351  )))
352 -|(((
349 +|(% style="width:110px" %)(((
353 353  (((
354 354  AT+STOPBIT
355 355  )))
356 -)))|(% style="width:285px" %)(((
353 +)))|(% style="width:200px" %)(((
357 357  (((
358 358  (((
359 359  Set serial stopbit (for RS485 connection)
... ... @@ -365,7 +365,7 @@
365 365  Default Value is: 1bit.
366 366  )))
367 367  )))
368 -)))|(% style="width:347px" %)(((
365 +)))|(% style="width:200px" %)(((
369 369  (((
370 370  (((
371 371  AT+STOPBIT=0 for 1bit
... ... @@ -813,7 +813,6 @@
813 813  
814 814  * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for RS485-BL.  User can see these commands below:
815 815  
816 -
817 817  === 3.5.1 Common Commands: ===
818 818  
819 819  They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
... ... @@ -1173,7 +1173,6 @@
1173 1173  |=(% style="width: 89px;" %)**Button**|=(% style="width: 141px;" %)**Feature**
1174 1174  |(% style="width:89px" %)**RST**|(% style="width:141px" %)Reboot RS485-BL
1175 1175  
1176 -
1177 1177  == 3.7 +3V3 Output ==
1178 1178  
1179 1179  RS485-BL has a Controllable +3V3 output, user can use this output to power external sensor.
... ... @@ -1214,7 +1214,6 @@
1214 1214  |=**LEDs**|=(% style="width: 274px;" %)**Feature**
1215 1215  |**LED1**|(% style="width:274px" %)Blink when device transmit a packet.
1216 1216  
1217 -
1218 1218  == 3.10 Switch Jumper ==
1219 1219  
1220 1220  (% border="1" style="background-color:#ffffcc; color:green; width:515px" %)
... ... @@ -1403,7 +1403,6 @@
1403 1403  * (% style="color:blue" %)**KZ865**(%%): frequency bands KZ865
1404 1404  
1405 1405  
1406 -
1407 1407  = 9. Packing Info =
1408 1408  
1409 1409  (((