Changes for page RS485-BL – Waterproof RS485 to LoRaWAN Converter
Last modified by Xiaoling on 2025/04/23 15:57
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 3 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1250,10 +1250,9 @@ 1250 1250 [[image:1654136435598-589.png]] 1251 1251 1252 1252 1253 -= 6. FAQ = 1253 +1. FAQ 1254 +11. How to upgrade the image? 1254 1254 1255 -== 6.1 How to upgrade the image? == 1256 - 1257 1257 The RS485-BL LoRaWAN Controller is shipped with a 3.5mm cable, the cable is used to upload image to RS485-BL to: 1258 1258 1259 1259 * Support new features ... ... @@ -1262,7 +1262,7 @@ 1262 1262 1263 1263 Below shows the hardware connection for how to upload an image to RS485-BL: 1264 1264 1265 -[[image: 1654136646995-976.png]]1264 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image030.png]] 1266 1266 1267 1267 **Step1:** Download [[flash loader>>url:https://www.st.com/content/st_com/en/products/development-tools/software-development-tools/stm32-software-development-tools/stm32-programmers/flasher-stm32.html]]. 1268 1268 ... ... @@ -1270,61 +1270,81 @@ 1270 1270 1271 1271 **Step3: **Open flashloader; choose the correct COM port to update. 1272 1272 1273 -[[image:image-20220602102605-1.png]] 1274 1274 1273 +|((( 1274 +HOLD PRO then press the RST button, SYS will be ON, then click next 1275 +))) 1275 1275 1276 -[[image:image-20220602102637-2.png]] 1277 +|((( 1278 +Board detected 1279 +))) 1277 1277 1281 +|((( 1282 + 1283 +))) 1278 1278 1279 -[[image:image -20220602102715-3.png]]1285 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image031.png]] [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image032.png]] 1280 1280 1281 1281 1282 1282 1283 - ==6.2 HowtongetheLoRaFrequency Bands/Region? ==1289 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image033.png]] [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image034.png]] 1284 1284 1285 -User can follow the introduction for [[how to upgrade image>>||anchor="H6.1Howtoupgradetheimage3F"]]. When download the images, choose the required image file for download. 1286 1286 1292 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image035.png]] [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image036.png]] 1287 1287 1288 1288 1289 -== 6.3 How many RS485-Slave can RS485-BL connects? == 1295 +1. 1296 +11. How to change the LoRa Frequency Bands/Region? 1290 1290 1291 - TheRS485-BLcansupportmax 32 RS485 devices.Each uplinkcommandofRS485-BLcansupport max 16differentRS485 command. So RS485-BL can support max 16 RS485devicespre-program inthedevice for uplink. Forotherdevicesnopre-program, usercan usethe[[downlinkmessage(type code 0xA8) to poll theirinfo>>||anchor="H3.3.3Configurereadcommandsforeachsampling"]].1298 +User can follow the introduction for [[how to upgrade image>>path:#upgrade_image]]. When download the images, choose the required image file for download. 1292 1292 1293 1293 1294 1294 1295 -= 7. Trouble Shooting = 1302 +1. 1303 +11. How many RS485-Slave can RS485-BL connects? 1296 1296 1305 +The RS485-BL can support max 32 RS485 devices. Each uplink command of RS485-BL can support max 16 different RS485 command. So RS485-BL can support max 16 RS485 devices pre-program in the device for uplink. For other devices no pre-program, user can use the [[downlink message (type code 0xA8) to poll their info>>path:#downlink_A8]]. 1297 1297 1298 -== 7.1 Downlink doesn’t work, how to solve it? == 1299 1299 1300 -Please see this link for debug: [[LoRaWAN Communication Debug>>doc:Main.LoRaWAN Communication Debug.WebHome]] 1301 1301 1302 1302 1303 -== 7.2 Why I can’t join TTN V3 in US915 /AU915 bands? == 1310 +1. Trouble Shooting 1311 +11. Downlink doesn’t work, how to solve it? 1304 1304 1305 - It might about the channels mapping.Please seefor detail:[[NoticeofFrequencyband>>doc:Main.LoRaWAN Communication Debug.WebHome||anchor="H2.NoticeofUS9152FCN4702FAU915Frequencyband"]]1313 +Please see this link for debug: 1306 1306 1315 +[[http:~~/~~/wiki.dragino.com/index.php?title=Main_Page#LoRaWAN_Communication_Debug>>url:http://wiki.dragino.com/index.php?title=Main_Page#LoRaWAN_Communication_Debug]] 1307 1307 1308 -= 8. Order Info = 1309 1309 1310 -(% style="color:bule" %)**Part Number: RS485-BL-XXX** 1311 1311 1312 -(% style="color:bule" %)**XXX:** 1319 +1. 1320 +11. Why I can’t join TTN V3 in US915 /AU915 bands? 1313 1313 1314 -* (% style="color:bule" %)**EU433**(%%): frequency bands EU433 1315 -* (% style="color:bule" %)**EU868**(%%): frequency bands EU868 1316 -* (% style="color:bule" %)**KR920**(%%): frequency bands KR920 1317 -* (% style="color:bule" %)**CN470**(%%): frequency bands CN470 1318 -* (% style="color:bule" %)**AS923**(%%): frequency bands AS923 1319 -* (% style="color:bule" %)**AU915**(%%): frequency bands AU915 1320 -* (% style="color:bule" %)**US915**(%%): frequency bands US915 1321 -* (% style="color:bule" %)**IN865**(%%): frequency bands IN865 1322 -* (% style="color:bule" %)**RU864**(%%): frequency bands RU864 1323 -* (% style="color:bule" %)**KZ865**(%%): frequency bands KZ865 1322 +It might about the channels mapping. Please see for detail. 1324 1324 1324 +[[http:~~/~~/wiki.dragino.com/index.php?title=LoRaWAN_Communication_Debug#Notice_of_US915.2FCN470.2FAU915_Frequency_band>>url:http://wiki.dragino.com/index.php?title=LoRaWAN_Communication_Debug#Notice_of_US915.2FCN470.2FAU915_Frequency_band]] 1325 1325 1326 -= 9. Packing Info = 1327 1327 1327 + 1328 +1. Order Info 1329 + 1330 +**Part Number: RS485-BL-XXX** 1331 + 1332 +**XXX:** 1333 + 1334 +* **EU433**: frequency bands EU433 1335 +* **EU868**: frequency bands EU868 1336 +* **KR920**: frequency bands KR920 1337 +* **CN470**: frequency bands CN470 1338 +* **AS923**: frequency bands AS923 1339 +* **AU915**: frequency bands AU915 1340 +* **US915**: frequency bands US915 1341 +* **IN865**: frequency bands IN865 1342 +* **RU864**: frequency bands RU864 1343 +* **KZ865: **frequency bands KZ865 1344 + 1345 +1. Packing Info 1346 + 1328 1328 **Package Includes**: 1329 1329 1330 1330 * RS485-BL x 1 ... ... @@ -1338,9 +1338,8 @@ 1338 1338 * Package Size / pcs : 14.5 x 8 x 5 cm 1339 1339 * Weight / pcs : 170g 1340 1340 1360 +1. Support 1341 1341 1342 -= 10. Support = 1343 - 1344 1344 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule. 1345 1345 * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to 1346 1346
- image-20220602102605-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -102.6 KB - Content
- image-20220602102637-2.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -250.8 KB - Content
- image-20220602102715-3.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -176.2 KB - Content