... ... @@ -1219,37 +1219,36 @@
1219 1219  === 5.5.2 Single-channel ABP mode (Use with LG01/LG02) ===
1220 1220  
1221 1221  
1222 -(% style="background-color:#dcdcdc" %)**AT+FDR** (%%) Reset Parameters to Factory Default, Keys Reserve
1222 +AT+FDR   Reset Parameters to Factory Default, Keys Reserve
1223 1223  
1224 -(% style="background-color:#dcdcdc" %)**AT+NJM=0 **(%%)Set to ABP mode
1224 +AT+NJM=0 Set to ABP mode
1225 1225  
1226 -(% style="background-color:#dcdcdc" %)**AT+ADR=0** (%%)Set the Adaptive Data Rate Off
1226 +AT+ADR=0 Set the Adaptive Data Rate Off
1227 1227  
1228 -(% style="background-color:#dcdcdc" %)**AT+DR=5**  (%%)Set Data Rate
1228 +AT+DR=5  Set Data Rate
1229 1229  
1230 -(% style="background-color:#dcdcdc" %)**AT+TDC=60000** (%%) Set transmit interval to 60 seconds
1230 +AT+TDC=60000  Set transmit interval to 60 seconds
1231 1231  
1232 -(% style="background-color:#dcdcdc" %)**AT+CHS=868400000**(%%) Set transmit frequency to 868.4Mhz
1232 +AT+CHS=868400000 Set transmit frequency to 868.4Mhz
1233 1233  
1234 -(% style="background-color:#dcdcdc" %)**AT+RX2FQ=868400000** (%%) Set RX2Frequency to 868.4Mhz (according to the result from server)
1234 +AT+RX2FQ=868400000 Set RX2Frequency to 868.4Mhz (according to the result from server)
1235 1235  
1236 -(% style="background-color:#dcdcdc" %)**AT+RX2DR=5**  (%%) Set RX2DR to match the downlink DR from server. see below
1236 +AT+RX2DR=5  Set RX2DR to match the downlink DR from server. see below
1237 1237  
1238 -(% style="background-color:#dcdcdc" %)**AT+DADDR=26** (%%) 01 1A F1 Set Device Address to 26 01 1A F1, this ID can be found in the LoRa Server portal.
1238 +AT+DADDR=26 01 1A F1 Set Device Address to 26 01 1A F1, this ID can be found in the LoRa Server portal.
1239 1239  
1240 -(% style="background-color:#dcdcdc" %)**ATZ**       (%%) Reset MCU
1240 +ATZ          Reset MCU
1241 1241  
1242 +**Note:**
1242 1242  
1243 -(% style="color:red" %)**Note:**
1244 +1. Make sure the device is set to ABP mode in the IoT Server.
1245 +1. Make sure the LG01/02 gateway RX frequency is exactly the same as AT+CHS setting.
1246 +1. Make sure SF / bandwidth setting in LG01/LG02 match the settings of AT+DR. refer [[this link>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/&file=LoRaWAN%201.0.3%20Regional%20Parameters.xlsx]] to see what DR means.
1247 +1. The command AT+RX2FQ and AT+RX2DR is to let downlink work. to set the correct parameters, user can check the actually downlink parameters to be used. As below. Which shows the RX2FQ should use 868400000 and RX2DR should be 5
1244 1244  
1245 -(% style="color:red" %)1. Make sure the device is set to ABP mode in the IoT Server.
1246 -2. Make sure the LG01/02 gateway RX frequency is exactly the same as AT+CHS setting.
1247 -3. Make sure SF / bandwidth setting in LG01/LG02 match the settings of AT+DR. refer [[this link>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/&file=LoRaWAN%201.0.3%20Regional%20Parameters.xlsx]] to see what DR means.
1248 -4. The command AT+RX2FQ and AT+RX2DR is to let downlink work. to set the correct parameters, user can check the actually downlink parameters to be used. As below. Which shows the RX2FQ should use 868400000 and RX2DR should be 5
1249 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image029.png]]
1249 1249  
1250 -[[image:1654136435598-589.png]]
1251 1251  
1252 -
1253 1253  1. FAQ
1254 1254  11. How to upgrade the image?
1255 1255  
1654136435598-589.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -158.9 KB
Content
1654136646995-976.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -1.3 MB
Content