... ... @@ -1239,19 +1239,21 @@ 1239 1239 1240 1240 (% style="background-color:#dcdcdc" %)**ATZ** (%%) Reset MCU 1241 1241 1242 + 1242 1242 (% style="color:red" %)**Note:** 1243 1243 1244 -1. Make sure the device is set to ABP mode in the IoT Server. 1245 - 1. Make sure the LG01/02 gateway RX frequency is exactly the same as AT+CHS setting.1246 - 1. Make sure SF / bandwidth setting in LG01/LG02 match the settings of AT+DR. refer [[this link>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/&file=LoRaWAN%201.0.3%20Regional%20Parameters.xlsx]] to see what DR means.1247 - 1. The command AT+RX2FQ and AT+RX2DR is to let downlink work. to set the correct parameters, user can check the actually downlink parameters to be used. As below. Which shows the RX2FQ should use 868400000 and RX2DR should be 51245 +(% style="color:red" %)1. Make sure the device is set to ABP mode in the IoT Server. 1246 +2. Make sure the LG01/02 gateway RX frequency is exactly the same as AT+CHS setting. 1247 +3. Make sure SF / bandwidth setting in LG01/LG02 match the settings of AT+DR. refer [[this link>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/&file=LoRaWAN%201.0.3%20Regional%20Parameters.xlsx]] to see what DR means. 1248 +4. The command AT+RX2FQ and AT+RX2DR is to let downlink work. to set the correct parameters, user can check the actually downlink parameters to be used. As below. Which shows the RX2FQ should use 868400000 and RX2DR should be 5 1248 1248 1249 -[[image: file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image029.png]]1250 +[[image:1654136435598-589.png]] 1250 1250 1251 1251 1252 -1. FAQ 1253 -11. How to upgrade the image? 1253 += 6. FAQ = 1254 1254 1255 +== 6.1 How to upgrade the image? == 1256 + 1255 1255 The RS485-BL LoRaWAN Controller is shipped with a 3.5mm cable, the cable is used to upload image to RS485-BL to: 1256 1256 1257 1257 * Support new features ... ... @@ -1260,7 +1260,7 @@ 1260 1260 1261 1261 Below shows the hardware connection for how to upload an image to RS485-BL: 1262 1262 1263 -[[image: file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image030.png]]1265 +[[image:1654136646995-976.png]] 1264 1264 1265 1265 **Step1:** Download [[flash loader>>url:https://www.st.com/content/st_com/en/products/development-tools/software-development-tools/stm32-software-development-tools/stm32-programmers/flasher-stm32.html]]. 1266 1266 ... ... @@ -1268,29 +1268,11 @@ 1268 1268 1269 1269 **Step3: **Open flashloader; choose the correct COM port to update. 1270 1270 1273 +[[image:image-20220602102605-1.png]] 1271 1271 1272 -|((( 1273 -HOLD PRO then press the RST button, SYS will be ON, then click next 1274 -))) 1275 1275 1276 -|((( 1277 -Board detected 1278 -))) 1279 1279 1280 -|((( 1281 - 1282 -))) 1283 1283 1284 -[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image031.png]] [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image032.png]] 1285 - 1286 - 1287 - 1288 -[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image033.png]] [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image034.png]] 1289 - 1290 - 1291 -[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image035.png]] [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image036.png]] 1292 - 1293 - 1294 1294 1. 1295 1295 11. How to change the LoRa Frequency Bands/Region? 1296 1296
- 1654136646995-976.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +1.3 MB - Content
- image-20220602102605-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +102.6 KB - Content