... ... @@ -1241,12 +1241,12 @@
1241 1241  
1242 1242  (% style="color:red" %)**Note:**
1243 1243  
1244 -1. Make sure the device is set to ABP mode in the IoT Server.
1245 -1. Make sure the LG01/02 gateway RX frequency is exactly the same as AT+CHS setting.
1246 -1. Make sure SF / bandwidth setting in LG01/LG02 match the settings of AT+DR. refer [[this link>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/&file=LoRaWAN%201.0.3%20Regional%20Parameters.xlsx]] to see what DR means.
1247 -1. The command AT+RX2FQ and AT+RX2DR is to let downlink work. to set the correct parameters, user can check the actually downlink parameters to be used. As below. Which shows the RX2FQ should use 868400000 and RX2DR should be 5
1244 +(% style="color:red" %)1. Make sure the device is set to ABP mode in the IoT Server.
1245 +2. Make sure the LG01/02 gateway RX frequency is exactly the same as AT+CHS setting.
1246 +3. Make sure SF / bandwidth setting in LG01/LG02 match the settings of AT+DR. refer [[this link>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/&file=LoRaWAN%201.0.3%20Regional%20Parameters.xlsx]] to see what DR means.
1247 +4. The command AT+RX2FQ and AT+RX2DR is to let downlink work. to set the correct parameters, user can check the actually downlink parameters to be used. As below. Which shows the RX2FQ should use 868400000 and RX2DR should be 5
1248 1248  
1249 -[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image029.png]]
1249 +[[image:1654136435598-589.png]]
1250 1250  
1251 1251  
1252 1252  1. FAQ
... ... @@ -1291,7 +1291,7 @@
1291 1291  [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image035.png]] [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image036.png]]
1292 1292  
1293 1293  
1294 -1.
1294 +1.
1295 1295  11. How to change the LoRa Frequency Bands/Region?
1296 1296  
1297 1297  User can follow the introduction for [[how to upgrade image>>path:#upgrade_image]]. When download the images, choose the required image file for download.
... ... @@ -1298,7 +1298,7 @@
1298 1298  
1299 1299  
1300 1300  
1301 -1.
1301 +1.
1302 1302  11. How many RS485-Slave can RS485-BL connects?
1303 1303  
1304 1304  The RS485-BL can support max 32 RS485 devices. Each uplink command of RS485-BL can support max 16 different RS485 command. So RS485-BL can support max 16 RS485 devices pre-program in the device for uplink. For other devices no pre-program, user can use the [[downlink message (type code 0xA8) to poll their info>>path:#downlink_A8]].
... ... @@ -1315,7 +1315,7 @@
1315 1315  
1316 1316  
1317 1317  
1318 -1.
1318 +1.
1319 1319  11. Why I can’t join TTN V3 in US915 /AU915 bands?
1320 1320  
1321 1321  It might about the channels mapping. Please see for detail.