... ... @@ -1164,6 +1164,7 @@
1164 1164  User can check this URL for some case studies: [[APP RS485 COMMUNICATE WITH SENSORS>>doc:Main.Application Note \: Communicate with Different Sensors ----- RS485-LN RS485-BL.WebHome]]
1165 1165  
1166 1166  
1167 +
1167 1167  = 5. Use AT Command =
1168 1168  
1169 1169  == 5.1 Access AT Command ==
... ... @@ -1170,77 +1170,64 @@
1170 1170  
1171 1171  RS485-BL supports AT Command set. User can use a USB to TTL adapter plus the 3.5mm Program Cable to connect to RS485-BL to use AT command, as below.
1172 1172  
1173 -[[image:1654135840598-282.png]]
1174 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image027.png]]
1174 1174  
1175 1175  
1176 -In PC, User needs to set (% style="color:blue" %)**serial tool**(%%)(such as [[putty>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to (% style="color:green" %)**9600**(%%) to access to access serial console of RS485-BL. The default password is 123456. Below is the output for reference:
1177 +In PC, User needs to set **serial tool**(such as [[putty>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to **9600** to access to access serial console of RS485-BL. The default password is 123456. Below is the output for reference:
1177 1177  
1178 -[[image:1654136105500-922.png]]
1179 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image028.png]]
1179 1179  
1180 1180  
1181 -More detail AT Command manual can be found at [[AT Command Manual>>||anchor="3.5ConfigureRS485-BLviaATorDownlink"]]
1182 1182  
1183 +More detail AT Command manual can be found at [[AT Command Manual>>path:#AT_COMMAND]]
1183 1183  
1184 -== 5.2 Common AT Command Sequence ==
1185 1185  
1186 -=== 5.2.1 Multi-channel ABP mode (Use with SX1301/LG308) ===
1187 1187  
1187 +1.
1188 +11. Common AT Command Sequence
1189 +111. Multi-channel ABP mode (Use with SX1301/LG308)
1190 +
1188 1188  If device has not joined network yet:
1189 1189  
1190 -(% class="box infomessage" %)
1191 -(((
1192 -**AT+FDR**
1193 -)))
1193 +AT+FDR
1194 1194  
1195 -(% class="box infomessage" %)
1196 -(((
1197 -**AT+NJM=0**
1198 -)))
1195 +AT+NJM=0
1199 1199  
1200 -(% class="box infomessage" %)
1201 -(((
1202 -**ATZ**
1203 -)))
1197 +ATZ
1204 1204  
1205 1205  
1206 1206  If device already joined network:
1207 1207  
1208 -(% class="box infomessage" %)
1209 -(((
1210 -**AT+NJM=0**
1211 -)))
1202 +AT+NJM=0
1212 1212  
1213 -(% class="box infomessage" %)
1214 -(((
1215 -**ATZ**
1216 -)))
1204 +ATZ
1217 1217  
1206 +1.
1207 +11.
1208 +111. Single-channel ABP mode (Use with LG01/LG02)
1218 1218  
1219 -=== 5.5.2 Single-channel ABP mode (Use with LG01/LG02) ===
1210 +AT+FDR   Reset Parameters to Factory Default, Keys Reserve
1220 1220  
1212 +AT+NJM=0 Set to ABP mode
1221 1221  
1222 -(% style="background-color:#dcdcdc" %)**AT+FDR** (%%) Reset Parameters to Factory Default, Keys Reserve
1214 +AT+ADR=0 Set the Adaptive Data Rate Off
1223 1223  
1224 -(% style="background-color:#dcdcdc" %)**AT+NJM=0 **(%%)Set to ABP mode
1216 +AT+DR= Set Data Rate
1225 1225  
1226 -(% style="background-color:#dcdcdc" %)**AT+ADR=0** (%%)Set the Adaptive Data Rate Off
1218 +AT+TDC=60000  Set transmit interval to 60 seconds
1227 1227  
1228 -(% style="background-color:#dcdcdc" %)**AT+DR=5**  (%%)Set Data Rate
1220 +AT+CHS=868400000 Set transmit frequency to 868.4Mhz
1229 1229  
1230 -(% style="background-color:#dcdcdc" %)**AT+TDC=60000** (%%) Set transmit interval to 60 seconds
1222 +AT+RX2FQ=868400000 Set RX2Frequency to 868.4Mhz (according to the result from server)
1231 1231  
1232 -(% style="background-color:#dcdcdc" %)**AT+CHS=868400000**(%%) Set transmit frequency to 868.4Mhz
1224 +AT+RX2DR= Set RX2DR to match the downlink DR from server. see below
1233 1233  
1234 -(% style="background-color:#dcdcdc" %)**AT+RX2FQ=868400000** (%%) Set RX2Frequency to 868.4Mhz (according to the result from server)
1226 +AT+DADDR=26 01 1A F1 Set Device Address to 26 01 1A F1, this ID can be found in the LoRa Server portal.
1235 1235  
1236 -(% style="background-color:#dcdcdc" %)**AT+RX2DR=5**  (%%) Set RX2DR to match the downlink DR from server. see below
1228 +ATZ          Reset MCU
1237 1237  
1238 -(% style="background-color:#dcdcdc" %)**AT+DADDR=26** (%%) 01 1A F1 Set Device Address to 26 01 1A F1, this ID can be found in the LoRa Server portal.
1230 +**Note:**
1239 1239  
1240 -(% style="background-color:#dcdcdc" %)**ATZ**       (%%) Reset MCU
1241 -
1242 -(% style="color:red" %)**Note:**
1243 -
1244 1244  1. Make sure the device is set to ABP mode in the IoT Server.
1245 1245  1. Make sure the LG01/02 gateway RX frequency is exactly the same as AT+CHS setting.
1246 1246  1. Make sure SF / bandwidth setting in LG01/LG02 match the settings of AT+DR. refer [[this link>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/&file=LoRaWAN%201.0.3%20Regional%20Parameters.xlsx]] to see what DR means.
1654136105500-922.png