Changes for page RS485-BL – Waterproof RS485 to LoRaWAN Converter
Last modified by Xiaoling on 2025/04/23 15:57
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 3 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1219,39 +1219,41 @@ 1219 1219 === 5.5.2 Single-channel ABP mode (Use with LG01/LG02) === 1220 1220 1221 1221 1222 -AT+FDR 1222 +(% style="background-color:#dcdcdc" %)**AT+FDR** (%%) Reset Parameters to Factory Default, Keys Reserve 1223 1223 1224 -AT+NJM=0 Set to ABP mode 1224 +(% style="background-color:#dcdcdc" %)**AT+NJM=0 **(%%)Set to ABP mode 1225 1225 1226 -AT+ADR=0 Set the Adaptive Data Rate Off 1226 +(% style="background-color:#dcdcdc" %)**AT+ADR=0** (%%)Set the Adaptive Data Rate Off 1227 1227 1228 -AT+DR=5 Set Data Rate 1228 +(% style="background-color:#dcdcdc" %)**AT+DR=5** (%%)Set Data Rate 1229 1229 1230 -AT+TDC=60000 1230 +(% style="background-color:#dcdcdc" %)**AT+TDC=60000** (%%) Set transmit interval to 60 seconds 1231 1231 1232 -AT+CHS=868400000 Set transmit frequency to 868.4Mhz 1232 +(% style="background-color:#dcdcdc" %)**AT+CHS=868400000**(%%) Set transmit frequency to 868.4Mhz 1233 1233 1234 -AT+RX2FQ=868400000 Set RX2Frequency to 868.4Mhz (according to the result from server) 1234 +(% style="background-color:#dcdcdc" %)**AT+RX2FQ=868400000** (%%) Set RX2Frequency to 868.4Mhz (according to the result from server) 1235 1235 1236 -AT+RX2DR=5 Set RX2DR to match the downlink DR from server. see below 1236 +(% style="background-color:#dcdcdc" %)**AT+RX2DR=5** (%%) Set RX2DR to match the downlink DR from server. see below 1237 1237 1238 -AT+DADDR=26 01 1A F1 Set Device Address to 26 01 1A F1, this ID can be found in the LoRa Server portal. 1238 +(% style="background-color:#dcdcdc" %)**AT+DADDR=26** (%%) 01 1A F1 Set Device Address to 26 01 1A F1, this ID can be found in the LoRa Server portal. 1239 1239 1240 -ATZ 1240 +(% style="background-color:#dcdcdc" %)**ATZ** (%%) Reset MCU 1241 1241 1242 -**Note:** 1243 1243 1244 -1. Make sure the device is set to ABP mode in the IoT Server. 1245 -1. Make sure the LG01/02 gateway RX frequency is exactly the same as AT+CHS setting. 1246 -1. Make sure SF / bandwidth setting in LG01/LG02 match the settings of AT+DR. refer [[this link>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/&file=LoRaWAN%201.0.3%20Regional%20Parameters.xlsx]] to see what DR means. 1247 -1. The command AT+RX2FQ and AT+RX2DR is to let downlink work. to set the correct parameters, user can check the actually downlink parameters to be used. As below. Which shows the RX2FQ should use 868400000 and RX2DR should be 5 1243 +(% style="color:red" %)**Note:** 1248 1248 1249 -[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image029.png]] 1245 +(% style="color:red" %)1. Make sure the device is set to ABP mode in the IoT Server. 1246 +2. Make sure the LG01/02 gateway RX frequency is exactly the same as AT+CHS setting. 1247 +3. Make sure SF / bandwidth setting in LG01/LG02 match the settings of AT+DR. refer [[this link>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/&file=LoRaWAN%201.0.3%20Regional%20Parameters.xlsx]] to see what DR means. 1248 +4. The command AT+RX2FQ and AT+RX2DR is to let downlink work. to set the correct parameters, user can check the actually downlink parameters to be used. As below. Which shows the RX2FQ should use 868400000 and RX2DR should be 5 1250 1250 1250 +[[image:1654136435598-589.png]] 1251 1251 1252 -1. FAQ 1253 -11. How to upgrade the image? 1254 1254 1253 += 6. FAQ = 1254 + 1255 +== 6.1 How to upgrade the image? == 1256 + 1255 1255 The RS485-BL LoRaWAN Controller is shipped with a 3.5mm cable, the cable is used to upload image to RS485-BL to: 1256 1256 1257 1257 * Support new features ... ... @@ -1260,7 +1260,7 @@ 1260 1260 1261 1261 Below shows the hardware connection for how to upload an image to RS485-BL: 1262 1262 1263 -[[image: file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image030.png]]1265 +[[image:1654136646995-976.png]] 1264 1264 1265 1265 **Step1:** Download [[flash loader>>url:https://www.st.com/content/st_com/en/products/development-tools/software-development-tools/stm32-software-development-tools/stm32-programmers/flasher-stm32.html]]. 1266 1266 ... ... @@ -1291,7 +1291,7 @@ 1291 1291 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image035.png]] [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image036.png]] 1292 1292 1293 1293 1294 -1. 1296 +1. 1295 1295 11. How to change the LoRa Frequency Bands/Region? 1296 1296 1297 1297 User can follow the introduction for [[how to upgrade image>>path:#upgrade_image]]. When download the images, choose the required image file for download. ... ... @@ -1298,7 +1298,7 @@ 1298 1298 1299 1299 1300 1300 1301 -1. 1303 +1. 1302 1302 11. How many RS485-Slave can RS485-BL connects? 1303 1303 1304 1304 The RS485-BL can support max 32 RS485 devices. Each uplink command of RS485-BL can support max 16 different RS485 command. So RS485-BL can support max 16 RS485 devices pre-program in the device for uplink. For other devices no pre-program, user can use the [[downlink message (type code 0xA8) to poll their info>>path:#downlink_A8]]. ... ... @@ -1315,7 +1315,7 @@ 1315 1315 1316 1316 1317 1317 1318 -1. 1320 +1. 1319 1319 11. Why I can’t join TTN V3 in US915 /AU915 bands? 1320 1320 1321 1321 It might about the channels mapping. Please see for detail.
- 1654136435598-589.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +158.9 KB - Content
- 1654136646995-976.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +1.3 MB - Content
- image-20220602102605-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +102.6 KB - Content