... ... @@ -1139,6 +1139,7 @@
1139 1139  |=**LEDs**|=(% style="width: 274px;" %)**Feature**
1140 1140  |**LED1**|(% style="width:274px" %)Blink when device transmit a packet.
1141 1141  
1142 +
1142 1142  == 3.10 Switch Jumper ==
1143 1143  
1144 1144  (% border="1" style="background-color:#ffffcc; color:green; width:515px" %)
... ... @@ -1161,64 +1161,54 @@
1161 1161  
1162 1162  = 4. Case Study =
1163 1163  
1164 -User can check this URL for some case studies: [[APP RS485 COMMUNICATE WITH SENSORS>>doc:Main.Application Note \: Communicate with Different Sensors ----- RS485-LN RS485-BL.WebHome]]
1165 +User can check this URL for some case studies.
1165 1165  
1167 +[[http:~~/~~/wiki.dragino.com/index.php?title=APP_RS485_COMMUNICATE_WITH_SENSORS>>url:http://wiki.dragino.com/index.php?title=APP_RS485_COMMUNICATE_WITH_SENSORS]]
1166 1166  
1167 -= 5. Use AT Command =
1168 1168  
1169 -== 5.1 Access AT Command ==
1170 1170  
1171 +
1172 +1. Use AT Command
1173 +11. Access AT Command
1174 +
1171 1171  RS485-BL supports AT Command set. User can use a USB to TTL adapter plus the 3.5mm Program Cable to connect to RS485-BL to use AT command, as below.
1172 1172  
1173 -[[image:1654135840598-282.png]]
1177 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image027.png]]
1174 1174  
1175 1175  
1176 -In PC, User needs to set (% style="color:blue" %)**serial tool**(%%)(such as [[putty>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to (% style="color:green" %)**9600**(%%) to access to access serial console of RS485-BL. The default password is 123456. Below is the output for reference:
1180 +In PC, User needs to set **serial tool**(such as [[putty>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to **9600** to access to access serial console of RS485-BL. The default password is 123456. Below is the output for reference:
1177 1177  
1178 -[[image:1654136105500-922.png]]
1182 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image028.png]]
1179 1179  
1180 1180  
1181 -More detail AT Command manual can be found at [[AT Command Manual>>||anchor="3.5ConfigureRS485-BLviaATorDownlink"]]
1182 1182  
1186 +More detail AT Command manual can be found at [[AT Command Manual>>path:#AT_COMMAND]]
1183 1183  
1184 -== 5.2 Common AT Command Sequence ==
1185 1185  
1186 -=== 5.2.1 Multi-channel ABP mode (Use with SX1301/LG308) ===
1187 1187  
1190 +1.
1191 +11. Common AT Command Sequence
1192 +111. Multi-channel ABP mode (Use with SX1301/LG308)
1193 +
1188 1188  If device has not joined network yet:
1189 1189  
1190 -(% class="box infomessage" %)
1191 -(((
1192 -**AT+FDR**
1193 -)))
1196 +AT+FDR
1194 1194  
1195 -(% class="box infomessage" %)
1196 -(((
1197 -**AT+NJM=0**
1198 -)))
1198 +AT+NJM=0
1199 1199  
1200 -(% class="box infomessage" %)
1201 -(((
1202 -**ATZ**
1203 -)))
1200 +ATZ
1204 1204  
1205 1205  
1206 1206  If device already joined network:
1207 1207  
1208 -(% class="box infomessage" %)
1209 -(((
1210 -**AT+NJM=0**
1211 -)))
1205 +AT+NJM=0
1212 1212  
1213 -(% class="box infomessage" %)
1214 -(((
1215 -**ATZ**
1216 -)))
1207 +ATZ
1217 1217  
1209 +1.
1210 +11.
1211 +111. Single-channel ABP mode (Use with LG01/LG02)
1218 1218  
1219 -=== 5.5.2 Single-channel ABP mode (Use with LG01/LG02) ===
1220 -
1221 -
1222 1222  AT+FDR   Reset Parameters to Factory Default, Keys Reserve
1223 1223  
1224 1224  AT+NJM=0 Set to ABP mode