Changes for page RS485-BL – Waterproof RS485 to LoRaWAN Converter
Last modified by Xiaoling on 2025/04/23 15:57
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1181,7 +1181,6 @@ 1181 1181 More detail AT Command manual can be found at [[AT Command Manual>>||anchor="3.5ConfigureRS485-BLviaATorDownlink"]] 1182 1182 1183 1183 1184 - 1185 1185 == 5.2 Common AT Command Sequence == 1186 1186 1187 1187 === 5.2.1 Multi-channel ABP mode (Use with SX1301/LG308) === ... ... @@ -1188,53 +1188,68 @@ 1188 1188 1189 1189 If device has not joined network yet: 1190 1190 1191 -AT+FDR 1190 +(% class="box infomessage" %) 1191 +((( 1192 +**AT+FDR** 1193 +))) 1192 1192 1193 -AT+NJM=0 1195 +(% class="box infomessage" %) 1196 +((( 1197 +**AT+NJM=0** 1198 +))) 1194 1194 1195 -ATZ 1200 +(% class="box infomessage" %) 1201 +((( 1202 +**ATZ** 1203 +))) 1196 1196 1197 1197 1198 1198 If device already joined network: 1199 1199 1200 -AT+NJM=0 1208 +(% class="box infomessage" %) 1209 +((( 1210 +**AT+NJM=0** 1211 +))) 1201 1201 1202 -ATZ 1213 +(% class="box infomessage" %) 1214 +((( 1215 +**ATZ** 1216 +))) 1203 1203 1204 -1. 1205 -11. 1206 -111. Single-channel ABP mode (Use with LG01/LG02) 1207 1207 1208 - AT+FDRResetParameters toFactoryDefault, Keys Reserve1219 +=== 5.5.2 Single-channel ABP mode (Use with LG01/LG02) === 1209 1209 1210 -AT+NJM=0 Set to ABP mode 1211 1211 1212 -AT+ ADR=0Set theAdaptiveDataRateOff1222 +(% style="background-color:#dcdcdc" %)**AT+FDR** (%%) Reset Parameters to Factory Default, Keys Reserve 1213 1213 1214 -AT+ DR=5SetDataRate1224 +(% style="background-color:#dcdcdc" %)**AT+NJM=0 **(%%)Set to ABP mode 1215 1215 1216 -AT+ TDC=60000Set transmitntervalto60 seconds1226 +(% style="background-color:#dcdcdc" %)**AT+ADR=0** (%%)Set the Adaptive Data Rate Off 1217 1217 1218 -AT+ CHS=868400000Settransmitfrequencyto 868.4Mhz1228 +(% style="background-color:#dcdcdc" %)**AT+DR=5** (%%)Set Data Rate 1219 1219 1220 -AT+ RX2FQ=868400000SetRX2Frequencyto868.4Mhz (accordingto theesultfromserver)1230 +(% style="background-color:#dcdcdc" %)**AT+TDC=60000** (%%) Set transmit interval to 60 seconds 1221 1221 1222 -AT+ RX2DR=5SetRX2DRto match the downlinkDRfrom server.see below1232 +(% style="background-color:#dcdcdc" %)**AT+CHS=868400000**(%%) Set transmit frequency to 868.4Mhz 1223 1223 1224 -AT+ DADDR=2611AF1SetDeviceAddressto2601 1A F1, thisID can be foundLoRaServerportal.1234 +(% style="background-color:#dcdcdc" %)**AT+RX2FQ=868400000** (%%) Set RX2Frequency to 868.4Mhz (according to the result from server) 1225 1225 1226 -AT ZtMCU1236 +(% style="background-color:#dcdcdc" %)**AT+RX2DR=5** (%%) Set RX2DR to match the downlink DR from server. see below 1227 1227 1228 - **Note:**1238 +(% style="background-color:#dcdcdc" %)**AT+DADDR=26** (%%) 01 1A F1 Set Device Address to 26 01 1A F1, this ID can be found in the LoRa Server portal. 1229 1229 1230 -1. Make sure the device is set to ABP mode in the IoT Server. 1231 -1. Make sure the LG01/02 gateway RX frequency is exactly the same as AT+CHS setting. 1232 -1. Make sure SF / bandwidth setting in LG01/LG02 match the settings of AT+DR. refer [[this link>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/&file=LoRaWAN%201.0.3%20Regional%20Parameters.xlsx]] to see what DR means. 1233 -1. The command AT+RX2FQ and AT+RX2DR is to let downlink work. to set the correct parameters, user can check the actually downlink parameters to be used. As below. Which shows the RX2FQ should use 868400000 and RX2DR should be 5 1240 +(% style="background-color:#dcdcdc" %)**ATZ** (%%) Reset MCU 1234 1234 1235 - [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image029.png]]1242 +(% style="color:red" %)**Note:** 1236 1236 1244 +(% style="color:red" %)1. Make sure the device is set to ABP mode in the IoT Server. 1245 +2. Make sure the LG01/02 gateway RX frequency is exactly the same as AT+CHS setting. 1246 +3. Make sure SF / bandwidth setting in LG01/LG02 match the settings of AT+DR. refer [[this link>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/&file=LoRaWAN%201.0.3%20Regional%20Parameters.xlsx]] to see what DR means. 1247 +4. The command AT+RX2FQ and AT+RX2DR is to let downlink work. to set the correct parameters, user can check the actually downlink parameters to be used. As below. Which shows the RX2FQ should use 868400000 and RX2DR should be 5 1237 1237 1249 +[[image:1654136435598-589.png]] 1250 + 1251 + 1238 1238 1. FAQ 1239 1239 11. How to upgrade the image? 1240 1240
- 1654136435598-589.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +158.9 KB - Content