... ... @@ -1164,6 +1164,7 @@
1164 1164  User can check this URL for some case studies: [[APP RS485 COMMUNICATE WITH SENSORS>>doc:Main.Application Note \: Communicate with Different Sensors ----- RS485-LN RS485-BL.WebHome]]
1165 1165  
1166 1166  
1167 +
1167 1167  = 5. Use AT Command =
1168 1168  
1169 1169  == 5.1 Access AT Command ==
... ... @@ -1170,21 +1170,22 @@
1170 1170  
1171 1171  RS485-BL supports AT Command set. User can use a USB to TTL adapter plus the 3.5mm Program Cable to connect to RS485-BL to use AT command, as below.
1172 1172  
1173 -[[image:1654135840598-282.png]]
1174 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image027.png]]
1174 1174  
1175 1175  
1176 -In PC, User needs to set (% style="color:blue" %)**serial tool**(%%)(such as [[putty>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to (% style="color:green" %)**9600**(%%) to access to access serial console of RS485-BL. The default password is 123456. Below is the output for reference:
1177 +In PC, User needs to set **serial tool**(such as [[putty>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to **9600** to access to access serial console of RS485-BL. The default password is 123456. Below is the output for reference:
1177 1177  
1178 -[[image:1654136105500-922.png]]
1179 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image028.png]]
1179 1179  
1180 1180  
1181 -More detail AT Command manual can be found at [[AT Command Manual>>||anchor="3.5ConfigureRS485-BLviaATorDownlink"]]
1182 1182  
1183 +More detail AT Command manual can be found at [[AT Command Manual>>path:#AT_COMMAND]]
1183 1183  
1184 1184  
1185 -== 5.2 Common AT Command Sequence ==
1186 1186  
1187 -=== 5.2.1 Multi-channel ABP mode (Use with SX1301/LG308) ===
1187 +1.
1188 +11. Common AT Command Sequence
1189 +111. Multi-channel ABP mode (Use with SX1301/LG308)
1188 1188  
1189 1189  If device has not joined network yet:
1190 1190  
... ... @@ -1201,8 +1201,8 @@
1201 1201  
1202 1202  ATZ
1203 1203  
1204 -1.
1205 -11.
1206 +1.
1207 +11.
1206 1206  111. Single-channel ABP mode (Use with LG01/LG02)
1207 1207  
1208 1208  AT+FDR   Reset Parameters to Factory Default, Keys Reserve
... ... @@ -1277,7 +1277,7 @@
1277 1277  [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image035.png]] [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image036.png]]
1278 1278  
1279 1279  
1280 -1.
1282 +1.
1281 1281  11. How to change the LoRa Frequency Bands/Region?
1282 1282  
1283 1283  User can follow the introduction for [[how to upgrade image>>path:#upgrade_image]]. When download the images, choose the required image file for download.
... ... @@ -1284,7 +1284,7 @@
1284 1284  
1285 1285  
1286 1286  
1287 -1.
1289 +1.
1288 1288  11. How many RS485-Slave can RS485-BL connects?
1289 1289  
1290 1290  The RS485-BL can support max 32 RS485 devices. Each uplink command of RS485-BL can support max 16 different RS485 command. So RS485-BL can support max 16 RS485 devices pre-program in the device for uplink. For other devices no pre-program, user can use the [[downlink message (type code 0xA8) to poll their info>>path:#downlink_A8]].
... ... @@ -1301,7 +1301,7 @@
1301 1301  
1302 1302  
1303 1303  
1304 -1.
1306 +1.
1305 1305  11. Why I can’t join TTN V3 in US915 /AU915 bands?
1306 1306  
1307 1307  It might about the channels mapping. Please see for detail.
1654136105500-922.png