Changes for page RS485-BL – Waterproof RS485 to LoRaWAN Converter
Last modified by Xiaoling on 2025/04/23 15:57
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 2 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1164,6 +1164,7 @@ 1164 1164 User can check this URL for some case studies: [[APP RS485 COMMUNICATE WITH SENSORS>>doc:Main.Application Note \: Communicate with Different Sensors ----- RS485-LN RS485-BL.WebHome]] 1165 1165 1166 1166 1167 + 1167 1167 = 5. Use AT Command = 1168 1168 1169 1169 == 5.1 Access AT Command == ... ... @@ -1170,21 +1170,22 @@ 1170 1170 1171 1171 RS485-BL supports AT Command set. User can use a USB to TTL adapter plus the 3.5mm Program Cable to connect to RS485-BL to use AT command, as below. 1172 1172 1173 -[[image: 1654135840598-282.png]]1174 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image027.png]] 1174 1174 1175 1175 1176 -In PC, User needs to set (% style="color:blue" %)**serial tool**(%%)(such as [[putty>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to(% style="color:green" %)**9600**(%%)to access to access serial console of RS485-BL. The default password is 123456. Below is the output for reference:1177 +In PC, User needs to set **serial tool**(such as [[putty>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to **9600** to access to access serial console of RS485-BL. The default password is 123456. Below is the output for reference: 1177 1177 1178 -[[image: 1654136105500-922.png]]1179 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image028.png]] 1179 1179 1180 1180 1181 -More detail AT Command manual can be found at [[AT Command Manual>>||anchor="3.5ConfigureRS485-BLviaATorDownlink"]] 1182 1182 1183 +More detail AT Command manual can be found at [[AT Command Manual>>path:#AT_COMMAND]] 1183 1183 1184 1184 1185 -== 5.2 Common AT Command Sequence == 1186 1186 1187 -=== 5.2.1 Multi-channel ABP mode (Use with SX1301/LG308) === 1187 +1. 1188 +11. Common AT Command Sequence 1189 +111. Multi-channel ABP mode (Use with SX1301/LG308) 1188 1188 1189 1189 If device has not joined network yet: 1190 1190 ... ... @@ -1201,8 +1201,8 @@ 1201 1201 1202 1202 ATZ 1203 1203 1204 -1. 1205 -11. 1206 +1. 1207 +11. 1206 1206 111. Single-channel ABP mode (Use with LG01/LG02) 1207 1207 1208 1208 AT+FDR Reset Parameters to Factory Default, Keys Reserve ... ... @@ -1277,7 +1277,7 @@ 1277 1277 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image035.png]] [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image036.png]] 1278 1278 1279 1279 1280 -1. 1282 +1. 1281 1281 11. How to change the LoRa Frequency Bands/Region? 1282 1282 1283 1283 User can follow the introduction for [[how to upgrade image>>path:#upgrade_image]]. When download the images, choose the required image file for download. ... ... @@ -1284,7 +1284,7 @@ 1284 1284 1285 1285 1286 1286 1287 -1. 1289 +1. 1288 1288 11. How many RS485-Slave can RS485-BL connects? 1289 1289 1290 1290 The RS485-BL can support max 32 RS485 devices. Each uplink command of RS485-BL can support max 16 different RS485 command. So RS485-BL can support max 16 RS485 devices pre-program in the device for uplink. For other devices no pre-program, user can use the [[downlink message (type code 0xA8) to poll their info>>path:#downlink_A8]]. ... ... @@ -1301,7 +1301,7 @@ 1301 1301 1302 1302 1303 1303 1304 -1. 1306 +1. 1305 1305 11. Why I can’t join TTN V3 in US915 /AU915 bands? 1306 1306 1307 1307 It might about the channels mapping. Please see for detail.
- 1654135840598-282.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -1.3 MB - Content
- 1654136105500-922.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -203.7 KB - Content