Changes for page RS485-BL – Waterproof RS485 to LoRaWAN Converter
Last modified by Xiaoling on 2025/04/23 15:57
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1173,69 +1173,82 @@ 1173 1173 [[image:1654135840598-282.png]] 1174 1174 1175 1175 1176 -In PC, User needs to set **serial tool**(such as [[putty>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to **9600** to access to access serial console of RS485-BL. The default password is 123456. Below is the output for reference: 1176 +In PC, User needs to set (% style="color:blue" %)**serial tool**(%%)(such as [[putty>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to (% style="color:green" %)**9600**(%%) to access to access serial console of RS485-BL. The default password is 123456. Below is the output for reference: 1177 1177 1178 -[[image: file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image028.png]]1178 +[[image:1654136105500-922.png]] 1179 1179 1180 1180 1181 +More detail AT Command manual can be found at [[AT Command Manual>>||anchor="3.5ConfigureRS485-BLviaATorDownlink"]] 1181 1181 1182 -More detail AT Command manual can be found at [[AT Command Manual>>path:#AT_COMMAND]] 1183 1183 1184 +== 5.2 Common AT Command Sequence == 1184 1184 1186 +=== 5.2.1 Multi-channel ABP mode (Use with SX1301/LG308) === 1185 1185 1186 -1. 1187 -11. Common AT Command Sequence 1188 -111. Multi-channel ABP mode (Use with SX1301/LG308) 1189 - 1190 1190 If device has not joined network yet: 1191 1191 1192 -AT+FDR 1190 +(% class="box infomessage" %) 1191 +((( 1192 +**AT+FDR** 1193 +))) 1193 1193 1194 -AT+NJM=0 1195 +(% class="box infomessage" %) 1196 +((( 1197 +**AT+NJM=0** 1198 +))) 1195 1195 1196 -ATZ 1200 +(% class="box infomessage" %) 1201 +((( 1202 +**ATZ** 1203 +))) 1197 1197 1198 1198 1199 1199 If device already joined network: 1200 1200 1201 -AT+NJM=0 1208 +(% class="box infomessage" %) 1209 +((( 1210 +**AT+NJM=0** 1211 +))) 1202 1202 1203 -ATZ 1213 +(% class="box infomessage" %) 1214 +((( 1215 +**ATZ** 1216 +))) 1204 1204 1205 -1. 1206 -11. 1207 -111. Single-channel ABP mode (Use with LG01/LG02) 1208 1208 1209 - AT+FDRResetParameters toFactoryDefault, Keys Reserve1219 +=== 5.5.2 Single-channel ABP mode (Use with LG01/LG02) === 1210 1210 1211 -AT+NJM=0 Set to ABP mode 1212 1212 1213 -AT+ ADR=0Set theAdaptiveDataRateOff1222 +(% style="background-color:#dcdcdc" %)**AT+FDR** (%%) Reset Parameters to Factory Default, Keys Reserve 1214 1214 1215 -AT+ DR=5SetDataRate1224 +(% style="background-color:#dcdcdc" %)**AT+NJM=0 **(%%)Set to ABP mode 1216 1216 1217 -AT+ TDC=60000Set transmitntervalto60 seconds1226 +(% style="background-color:#dcdcdc" %)**AT+ADR=0** (%%)Set the Adaptive Data Rate Off 1218 1218 1219 -AT+ CHS=868400000Settransmitfrequencyto 868.4Mhz1228 +(% style="background-color:#dcdcdc" %)**AT+DR=5** (%%)Set Data Rate 1220 1220 1221 -AT+ RX2FQ=868400000SetRX2Frequencyto868.4Mhz (accordingto theesultfromserver)1230 +(% style="background-color:#dcdcdc" %)**AT+TDC=60000** (%%) Set transmit interval to 60 seconds 1222 1222 1223 -AT+ RX2DR=5SetRX2DRto match the downlinkDRfrom server.see below1232 +(% style="background-color:#dcdcdc" %)**AT+CHS=868400000**(%%) Set transmit frequency to 868.4Mhz 1224 1224 1225 -AT+ DADDR=2611AF1SetDeviceAddressto2601 1A F1, thisID can be foundLoRaServerportal.1234 +(% style="background-color:#dcdcdc" %)**AT+RX2FQ=868400000** (%%) Set RX2Frequency to 868.4Mhz (according to the result from server) 1226 1226 1227 -AT ZtMCU1236 +(% style="background-color:#dcdcdc" %)**AT+RX2DR=5** (%%) Set RX2DR to match the downlink DR from server. see below 1228 1228 1229 - **Note:**1238 +(% style="background-color:#dcdcdc" %)**AT+DADDR=26** (%%) 01 1A F1 Set Device Address to 26 01 1A F1, this ID can be found in the LoRa Server portal. 1230 1230 1231 -1. Make sure the device is set to ABP mode in the IoT Server. 1232 -1. Make sure the LG01/02 gateway RX frequency is exactly the same as AT+CHS setting. 1233 -1. Make sure SF / bandwidth setting in LG01/LG02 match the settings of AT+DR. refer [[this link>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/&file=LoRaWAN%201.0.3%20Regional%20Parameters.xlsx]] to see what DR means. 1234 -1. The command AT+RX2FQ and AT+RX2DR is to let downlink work. to set the correct parameters, user can check the actually downlink parameters to be used. As below. Which shows the RX2FQ should use 868400000 and RX2DR should be 5 1240 +(% style="background-color:#dcdcdc" %)**ATZ** (%%) Reset MCU 1235 1235 1236 - [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image029.png]]1242 +(% style="color:red" %)**Note:** 1237 1237 1244 +(% style="color:red" %)1. Make sure the device is set to ABP mode in the IoT Server. 1245 +2. Make sure the LG01/02 gateway RX frequency is exactly the same as AT+CHS setting. 1246 +3. Make sure SF / bandwidth setting in LG01/LG02 match the settings of AT+DR. refer [[this link>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/&file=LoRaWAN%201.0.3%20Regional%20Parameters.xlsx]] to see what DR means. 1247 +4. The command AT+RX2FQ and AT+RX2DR is to let downlink work. to set the correct parameters, user can check the actually downlink parameters to be used. As below. Which shows the RX2FQ should use 868400000 and RX2DR should be 5 1238 1238 1249 +[[image:1654136435598-589.png]] 1250 + 1251 + 1239 1239 1. FAQ 1240 1240 11. How to upgrade the image? 1241 1241 ... ... @@ -1278,7 +1278,7 @@ 1278 1278 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image035.png]] [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image036.png]] 1279 1279 1280 1280 1281 -1. 1294 +1. 1282 1282 11. How to change the LoRa Frequency Bands/Region? 1283 1283 1284 1284 User can follow the introduction for [[how to upgrade image>>path:#upgrade_image]]. When download the images, choose the required image file for download. ... ... @@ -1285,7 +1285,7 @@ 1285 1285 1286 1286 1287 1287 1288 -1. 1301 +1. 1289 1289 11. How many RS485-Slave can RS485-BL connects? 1290 1290 1291 1291 The RS485-BL can support max 32 RS485 devices. Each uplink command of RS485-BL can support max 16 different RS485 command. So RS485-BL can support max 16 RS485 devices pre-program in the device for uplink. For other devices no pre-program, user can use the [[downlink message (type code 0xA8) to poll their info>>path:#downlink_A8]]. ... ... @@ -1302,7 +1302,7 @@ 1302 1302 1303 1303 1304 1304 1305 -1. 1318 +1. 1306 1306 11. Why I can’t join TTN V3 in US915 /AU915 bands? 1307 1307 1308 1308 It might about the channels mapping. Please see for detail.
- 1654136435598-589.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +158.9 KB - Content