Changes for page RS485-BL – Waterproof RS485 to LoRaWAN Converter
Last modified by Xiaoling on 2025/04/23 15:57
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1173,61 +1173,74 @@ 1173 1173 [[image:1654135840598-282.png]] 1174 1174 1175 1175 1176 -In PC, User needs to set **serial tool**(such as [[putty>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to **9600** to access to access serial console of RS485-BL. The default password is 123456. Below is the output for reference: 1176 +In PC, User needs to set (% style="color:blue" %)**serial tool**(%%)(such as [[putty>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to (% style="color:green" %)**9600**(%%) to access to access serial console of RS485-BL. The default password is 123456. Below is the output for reference: 1177 1177 1178 -[[image: file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image028.png]]1178 +[[image:1654136105500-922.png]] 1179 1179 1180 1180 1181 +More detail AT Command manual can be found at [[AT Command Manual>>||anchor="3.5ConfigureRS485-BLviaATorDownlink"]] 1181 1181 1182 -More detail AT Command manual can be found at [[AT Command Manual>>path:#AT_COMMAND]] 1183 1183 1184 +== 5.2 Common AT Command Sequence == 1184 1184 1186 +=== 5.2.1 Multi-channel ABP mode (Use with SX1301/LG308) === 1185 1185 1186 -1. 1187 -11. Common AT Command Sequence 1188 -111. Multi-channel ABP mode (Use with SX1301/LG308) 1189 - 1190 1190 If device has not joined network yet: 1191 1191 1192 -AT+FDR 1190 +(% class="box infomessage" %) 1191 +((( 1192 +**AT+FDR** 1193 +))) 1193 1193 1194 -AT+NJM=0 1195 +(% class="box infomessage" %) 1196 +((( 1197 +**AT+NJM=0** 1198 +))) 1195 1195 1196 -ATZ 1200 +(% class="box infomessage" %) 1201 +((( 1202 +**ATZ** 1203 +))) 1197 1197 1198 1198 1199 1199 If device already joined network: 1200 1200 1201 -AT+NJM=0 1208 +(% class="box infomessage" %) 1209 +((( 1210 +**AT+NJM=0** 1211 +))) 1202 1202 1203 -ATZ 1213 +(% class="box infomessage" %) 1214 +((( 1215 +**ATZ** 1216 +))) 1204 1204 1205 -1. 1206 -11. 1207 -111. Single-channel ABP mode (Use with LG01/LG02) 1208 1208 1209 - AT+FDRResetParameters toFactoryDefault, Keys Reserve1219 +=== 5.5.2 Single-channel ABP mode (Use with LG01/LG02) === 1210 1210 1211 -AT+NJM=0 Set to ABP mode 1212 1212 1213 -AT+ ADR=0Set theAdaptiveDataRateOff1222 +(% style="background-color:#dcdcdc" %)**AT+FDR** (%%) Reset Parameters to Factory Default, Keys Reserve 1214 1214 1215 -AT+ DR=5SetDataRate1224 +(% style="background-color:#dcdcdc" %)**AT+NJM=0 **(%%)Set to ABP mode 1216 1216 1217 -AT+ TDC=60000Set transmitntervalto60 seconds1226 +(% style="background-color:#dcdcdc" %)**AT+ADR=0** (%%)Set the Adaptive Data Rate Off 1218 1218 1219 -AT+ CHS=868400000Settransmitfrequencyto 868.4Mhz1228 +(% style="background-color:#dcdcdc" %)**AT+DR=5** (%%)Set Data Rate 1220 1220 1221 -AT+ RX2FQ=868400000SetRX2Frequencyto868.4Mhz (accordingto theesultfromserver)1230 +(% style="background-color:#dcdcdc" %)**AT+TDC=60000** (%%) Set transmit interval to 60 seconds 1222 1222 1223 -AT+ RX2DR=5SetRX2DRto match the downlinkDRfrom server.see below1232 +(% style="background-color:#dcdcdc" %)**AT+CHS=868400000**(%%) Set transmit frequency to 868.4Mhz 1224 1224 1225 -AT+ DADDR=2611AF1SetDeviceAddressto2601 1A F1, thisID can be foundLoRaServerportal.1234 +(% style="background-color:#dcdcdc" %)**AT+RX2FQ=868400000** (%%) Set RX2Frequency to 868.4Mhz (according to the result from server) 1226 1226 1227 -AT ZtMCU1236 +(% style="background-color:#dcdcdc" %)**AT+RX2DR=5** (%%) Set RX2DR to match the downlink DR from server. see below 1228 1228 1229 - **Note:**1238 +(% style="background-color:#dcdcdc" %)**AT+DADDR=26** (%%) 01 1A F1 Set Device Address to 26 01 1A F1, this ID can be found in the LoRa Server portal. 1230 1230 1240 +(% style="background-color:#dcdcdc" %)**ATZ** (%%) Reset MCU 1241 + 1242 +(% style="color:red" %)**Note:** 1243 + 1231 1231 1. Make sure the device is set to ABP mode in the IoT Server. 1232 1232 1. Make sure the LG01/02 gateway RX frequency is exactly the same as AT+CHS setting. 1233 1233 1. Make sure SF / bandwidth setting in LG01/LG02 match the settings of AT+DR. refer [[this link>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/&file=LoRaWAN%201.0.3%20Regional%20Parameters.xlsx]] to see what DR means.
- 1654136435598-589.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +158.9 KB - Content