Last modified by Xiaoling on 2025/04/23 15:57

From version 35.1
edited by Xiaoling
on 2022/06/02 10:15
Change comment: Uploaded new attachment "1654136105500-922.png", version {1}
To version 35.4
edited by Xiaoling
on 2022/06/02 10:17
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1173,39 +1173,52 @@
1173 1173  [[image:1654135840598-282.png]]
1174 1174  
1175 1175  
1176 -In PC, User needs to set **serial tool**(such as [[putty>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to **9600** to access to access serial console of RS485-BL. The default password is 123456. Below is the output for reference:
1176 +In PC, User needs to set (% style="color:blue" %)**serial tool**(%%)(such as [[putty>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to (% style="color:green" %)**9600**(%%) to access to access serial console of RS485-BL. The default password is 123456. Below is the output for reference:
1177 1177  
1178 -[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image028.png]]
1178 +[[image:1654136105500-922.png]]
1179 1179  
1180 1180  
1181 +More detail AT Command manual can be found at [[AT Command Manual>>||anchor="3.5ConfigureRS485-BLviaATorDownlink"]]
1181 1181  
1182 -More detail AT Command manual can be found at [[AT Command Manual>>path:#AT_COMMAND]]
1183 1183  
1184 +== 5.2 Common AT Command Sequence ==
1184 1184  
1186 +=== 5.2.1 Multi-channel ABP mode (Use with SX1301/LG308) ===
1185 1185  
1186 -1.
1187 -11. Common AT Command Sequence
1188 -111. Multi-channel ABP mode (Use with SX1301/LG308)
1189 -
1190 1190  If device has not joined network yet:
1191 1191  
1192 -AT+FDR
1190 +(% class="box infomessage" %)
1191 +(((
1192 +**AT+FDR**
1193 +)))
1193 1193  
1194 -AT+NJM=0
1195 +(% class="box infomessage" %)
1196 +(((
1197 +**AT+NJM=0**
1198 +)))
1195 1195  
1196 -ATZ
1200 +(% class="box infomessage" %)
1201 +(((
1202 +**ATZ**
1203 +)))
1197 1197  
1198 1198  
1199 1199  If device already joined network:
1200 1200  
1201 -AT+NJM=0
1208 +(% class="box infomessage" %)
1209 +(((
1210 +**AT+NJM=0**
1211 +)))
1202 1202  
1203 -ATZ
1213 +(% class="box infomessage" %)
1214 +(((
1215 +**ATZ**
1216 +)))
1204 1204  
1205 -1.
1206 -11.
1207 -111. Single-channel ABP mode (Use with LG01/LG02)
1208 1208  
1219 +=== 5.5.2 Single-channel ABP mode (Use with LG01/LG02) ===
1220 +
1221 +
1209 1209  AT+FDR   Reset Parameters to Factory Default, Keys Reserve
1210 1210  
1211 1211  AT+NJM=0 Set to ABP mode
... ... @@ -1278,7 +1278,7 @@
1278 1278  [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image035.png]] [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image036.png]]
1279 1279  
1280 1280  
1281 -1.
1294 +1.
1282 1282  11. How to change the LoRa Frequency Bands/Region?
1283 1283  
1284 1284  User can follow the introduction for [[how to upgrade image>>path:#upgrade_image]]. When download the images, choose the required image file for download.
... ... @@ -1285,7 +1285,7 @@
1285 1285  
1286 1286  
1287 1287  
1288 -1.
1301 +1.
1289 1289  11. How many RS485-Slave can RS485-BL connects?
1290 1290  
1291 1291  The RS485-BL can support max 32 RS485 devices. Each uplink command of RS485-BL can support max 16 different RS485 command. So RS485-BL can support max 16 RS485 devices pre-program in the device for uplink. For other devices no pre-program, user can use the [[downlink message (type code 0xA8) to poll their info>>path:#downlink_A8]].
... ... @@ -1302,7 +1302,7 @@
1302 1302  
1303 1303  
1304 1304  
1305 -1.
1318 +1.
1306 1306  11. Why I can’t join TTN V3 in US915 /AU915 bands?
1307 1307  
1308 1308  It might about the channels mapping. Please see for detail.