Last modified by Xiaoling on 2025/04/23 15:57

From version 34.1
edited by Xiaoling
on 2022/06/02 10:10
Change comment: Uploaded new attachment "1654135840598-282.png", version {1}
To version 35.5
edited by Xiaoling
on 2022/06/02 10:20
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1164,7 +1164,6 @@
1164 1164  User can check this URL for some case studies: [[APP RS485 COMMUNICATE WITH SENSORS>>doc:Main.Application Note \: Communicate with Different Sensors ----- RS485-LN RS485-BL.WebHome]]
1165 1165  
1166 1166  
1167 -
1168 1168  = 5. Use AT Command =
1169 1169  
1170 1170  == 5.1 Access AT Command ==
... ... @@ -1171,64 +1171,77 @@
1171 1171  
1172 1172  RS485-BL supports AT Command set. User can use a USB to TTL adapter plus the 3.5mm Program Cable to connect to RS485-BL to use AT command, as below.
1173 1173  
1174 -[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image027.png]]
1173 +[[image:1654135840598-282.png]]
1175 1175  
1176 1176  
1177 -In PC, User needs to set **serial tool**(such as [[putty>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to **9600** to access to access serial console of RS485-BL. The default password is 123456. Below is the output for reference:
1176 +In PC, User needs to set (% style="color:blue" %)**serial tool**(%%)(such as [[putty>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to (% style="color:green" %)**9600**(%%) to access to access serial console of RS485-BL. The default password is 123456. Below is the output for reference:
1178 1178  
1179 -[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image028.png]]
1178 +[[image:1654136105500-922.png]]
1180 1180  
1181 1181  
1181 +More detail AT Command manual can be found at [[AT Command Manual>>||anchor="3.5ConfigureRS485-BLviaATorDownlink"]]
1182 1182  
1183 -More detail AT Command manual can be found at [[AT Command Manual>>path:#AT_COMMAND]]
1184 1184  
1184 +== 5.2 Common AT Command Sequence ==
1185 1185  
1186 +=== 5.2.1 Multi-channel ABP mode (Use with SX1301/LG308) ===
1186 1186  
1187 -1.
1188 -11. Common AT Command Sequence
1189 -111. Multi-channel ABP mode (Use with SX1301/LG308)
1190 -
1191 1191  If device has not joined network yet:
1192 1192  
1193 -AT+FDR
1190 +(% class="box infomessage" %)
1191 +(((
1192 +**AT+FDR**
1193 +)))
1194 1194  
1195 -AT+NJM=0
1195 +(% class="box infomessage" %)
1196 +(((
1197 +**AT+NJM=0**
1198 +)))
1196 1196  
1197 -ATZ
1200 +(% class="box infomessage" %)
1201 +(((
1202 +**ATZ**
1203 +)))
1198 1198  
1199 1199  
1200 1200  If device already joined network:
1201 1201  
1202 -AT+NJM=0
1208 +(% class="box infomessage" %)
1209 +(((
1210 +**AT+NJM=0**
1211 +)))
1203 1203  
1204 -ATZ
1213 +(% class="box infomessage" %)
1214 +(((
1215 +**ATZ**
1216 +)))
1205 1205  
1206 -1.
1207 -11.
1208 -111. Single-channel ABP mode (Use with LG01/LG02)
1209 1209  
1210 -AT+FDR   Reset Parameters to Factory Default, Keys Reserve
1219 +=== 5.5.2 Single-channel ABP mode (Use with LG01/LG02) ===
1211 1211  
1212 -AT+NJM=0 Set to ABP mode
1213 1213  
1214 -AT+ADR=0 Set the Adaptive Data Rate Off
1222 +(% style="background-color:#dcdcdc" %)**AT+FDR** (%%) Reset Parameters to Factory Default, Keys Reserve
1215 1215  
1216 -AT+DR= Set Data Rate
1224 +(% style="background-color:#dcdcdc" %)**AT+NJM=0 **(%%)Set to ABP mode
1217 1217  
1218 -AT+TDC=60000  Set transmit interval to 60 seconds
1226 +(% style="background-color:#dcdcdc" %)**AT+ADR=0** (%%)Set the Adaptive Data Rate Off
1219 1219  
1220 -AT+CHS=868400000 Set transmit frequency to 868.4Mhz
1228 +(% style="background-color:#dcdcdc" %)**AT+DR=5**  (%%)Set Data Rate
1221 1221  
1222 -AT+RX2FQ=868400000 Set RX2Frequency to 868.4Mhz (according to the result from server)
1230 +(% style="background-color:#dcdcdc" %)**AT+TDC=60000** (%%) Set transmit interval to 60 seconds
1223 1223  
1224 -AT+RX2DR= Set RX2DR to match the downlink DR from server. see below
1232 +(% style="background-color:#dcdcdc" %)**AT+CHS=868400000**(%%) Set transmit frequency to 868.4Mhz
1225 1225  
1226 -AT+DADDR=26 01 1A F1 Set Device Address to 26 01 1A F1, this ID can be found in the LoRa Server portal.
1234 +(% style="background-color:#dcdcdc" %)**AT+RX2FQ=868400000** (%%) Set RX2Frequency to 868.4Mhz (according to the result from server)
1227 1227  
1228 -ATZ          Reset MCU
1236 +(% style="background-color:#dcdcdc" %)**AT+RX2DR=5**  (%%) Set RX2DR to match the downlink DR from server. see below
1229 1229  
1230 -**Note:**
1238 +(% style="background-color:#dcdcdc" %)**AT+DADDR=26** (%%) 01 1A F1 Set Device Address to 26 01 1A F1, this ID can be found in the LoRa Server portal.
1231 1231  
1240 +(% style="background-color:#dcdcdc" %)**ATZ**       (%%) Reset MCU
1241 +
1242 +(% style="color:red" %)**Note:**
1243 +
1232 1232  1. Make sure the device is set to ABP mode in the IoT Server.
1233 1233  1. Make sure the LG01/02 gateway RX frequency is exactly the same as AT+CHS setting.
1234 1234  1. Make sure SF / bandwidth setting in LG01/LG02 match the settings of AT+DR. refer [[this link>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/&file=LoRaWAN%201.0.3%20Regional%20Parameters.xlsx]] to see what DR means.
1654136105500-922.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +203.7 KB
Content