Changes for page RS485-BL – Waterproof RS485 to LoRaWAN Converter
Last modified by Xiaoling on 2025/04/23 15:57
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1164,7 +1164,6 @@ 1164 1164 User can check this URL for some case studies: [[APP RS485 COMMUNICATE WITH SENSORS>>doc:Main.Application Note \: Communicate with Different Sensors ----- RS485-LN RS485-BL.WebHome]] 1165 1165 1166 1166 1167 - 1168 1168 = 5. Use AT Command = 1169 1169 1170 1170 == 5.1 Access AT Command == ... ... @@ -1171,22 +1171,21 @@ 1171 1171 1172 1172 RS485-BL supports AT Command set. User can use a USB to TTL adapter plus the 3.5mm Program Cable to connect to RS485-BL to use AT command, as below. 1173 1173 1174 -[[image: file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image027.png]]1173 +[[image:1654135840598-282.png]] 1175 1175 1176 1176 1177 -In PC, User needs to set **serial tool**(such as [[putty>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to **9600** to access to access serial console of RS485-BL. The default password is 123456. Below is the output for reference: 1176 +In PC, User needs to set (% style="color:blue" %)**serial tool**(%%)(such as [[putty>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to (% style="color:green" %)**9600**(%%) to access to access serial console of RS485-BL. The default password is 123456. Below is the output for reference: 1178 1178 1179 -[[image: file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image028.png]]1178 +[[image:1654136105500-922.png]] 1180 1180 1181 1181 1181 +More detail AT Command manual can be found at [[AT Command Manual>>||anchor="3.5ConfigureRS485-BLviaATorDownlink"]] 1182 1182 1183 -More detail AT Command manual can be found at [[AT Command Manual>>path:#AT_COMMAND]] 1184 1184 1185 1185 1185 +== 5.2 Common AT Command Sequence == 1186 1186 1187 -1. 1188 -11. Common AT Command Sequence 1189 -111. Multi-channel ABP mode (Use with SX1301/LG308) 1187 +=== 5.2.1 Multi-channel ABP mode (Use with SX1301/LG308) === 1190 1190 1191 1191 If device has not joined network yet: 1192 1192 ... ... @@ -1203,8 +1203,8 @@ 1203 1203 1204 1204 ATZ 1205 1205 1206 -1. 1207 -11. 1204 +1. 1205 +11. 1208 1208 111. Single-channel ABP mode (Use with LG01/LG02) 1209 1209 1210 1210 AT+FDR Reset Parameters to Factory Default, Keys Reserve ... ... @@ -1279,7 +1279,7 @@ 1279 1279 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image035.png]] [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image036.png]] 1280 1280 1281 1281 1282 -1. 1280 +1. 1283 1283 11. How to change the LoRa Frequency Bands/Region? 1284 1284 1285 1285 User can follow the introduction for [[how to upgrade image>>path:#upgrade_image]]. When download the images, choose the required image file for download. ... ... @@ -1286,7 +1286,7 @@ 1286 1286 1287 1287 1288 1288 1289 -1. 1287 +1. 1290 1290 11. How many RS485-Slave can RS485-BL connects? 1291 1291 1292 1292 The RS485-BL can support max 32 RS485 devices. Each uplink command of RS485-BL can support max 16 different RS485 command. So RS485-BL can support max 16 RS485 devices pre-program in the device for uplink. For other devices no pre-program, user can use the [[downlink message (type code 0xA8) to poll their info>>path:#downlink_A8]]. ... ... @@ -1303,7 +1303,7 @@ 1303 1303 1304 1304 1305 1305 1306 -1. 1304 +1. 1307 1307 11. Why I can’t join TTN V3 in US915 /AU915 bands? 1308 1308 1309 1309 It might about the channels mapping. Please see for detail.
- 1654136105500-922.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +203.7 KB - Content