Changes for page RS485-BL – Waterproof RS485 to LoRaWAN Converter
Last modified by Xiaoling on 2025/04/23 15:57
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1012,57 +1012,52 @@ 1012 1012 The AT+COMMANDx and AT+DATACUTx settings are stored in special location, user can use below command to clear them. 1013 1013 1014 1014 1015 -* **AT Command:**1015 +* AT Command: 1016 1016 1017 - (% style="color:#037691" %)**AT+CMDEAR=mm,nn**(%%)mm: start position of erase ,nn: stop position of eraseEtc. AT+CMDEAR=1,10 means erase AT+COMMAND1/AT+DATACUT1 to AT+COMMAND10/AT+DATACUT101017 +**AT+CMDEAR=mm,nn** mm: start position of erase ,nn: stop position of erase 1018 1018 1019 +Etc. AT+CMDEAR=1,10 means erase AT+COMMAND1/AT+DATACUT1 to AT+COMMAND10/AT+DATACUT10 1020 + 1019 1019 Example screen shot after clear all RS485 commands. 1020 1020 1021 1021 1024 + 1022 1022 The uplink screen shot is: 1023 1023 1024 -[[image: 1654134704555-320.png]]1027 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image023.png]] 1025 1025 1026 1026 1027 -* **Downlink Payload:**1030 +* Downlink Payload: 1028 1028 1029 - **0x09 aa bb**same as AT+CMDEAR=aa,bb1032 +0x09 aa bb same as AT+CMDEAR=aa,bb 1030 1030 1031 1031 1035 +==== Set Serial Communication Parameters ==== 1032 1032 1033 -==== **Set Serial Communication Parameters** ==== 1034 - 1035 1035 Set the Rs485 serial communication parameters: 1036 1036 1037 -* **AT Command:**1039 +* AT Command: 1038 1038 1039 1039 Set Baud Rate: 1040 1040 1041 -(% class="box infomessage" %) 1042 -((( 1043 -**AT+BAUDR=9600** ~/~/ Options: (1200,2400,4800,14400,19200,115200) 1044 -))) 1043 +AT+BAUDR=9600 ~/~/ Options: (1200,2400,4800,14400,19200,115200) 1045 1045 1046 -Set UART Parity 1047 1047 1048 -(% class="box infomessage" %) 1049 -((( 1050 -**AT+PARITY=0** ~/~/ Option: 0: no parity, 1: odd parity, 2: even parity 1051 -))) 1046 +Set UART parity 1052 1052 1048 +AT+PARITY=0 ~/~/ Option: 0: no parity, 1: odd parity, 2: even parity 1049 + 1050 + 1053 1053 Set STOPBIT 1054 1054 1055 -(% class="box infomessage" %) 1056 -((( 1057 -**AT+STOPBIT=0** ~/~/ Option: 0 for 1bit; 1 for 1.5 bit ; 2 for 2 bits 1058 -))) 1053 +AT+STOPBIT=0 ~/~/ Option: 0 for 1bit; 1 for 1.5 bit ; 2 for 2 bits 1059 1059 1060 1060 1061 -* **Downlink Payload:**1056 +* Downlink Payload: 1062 1062 1063 - **A7 01 aa bb**: Same AT+BAUDR=hex(aa bb)*1001058 +A7 01 aa bb: Same AT+BAUDR=hex(aa bb)*100 1064 1064 1065 - **Example:**1060 +Example: 1066 1066 1067 1067 * A7 01 00 60 same as AT+BAUDR=9600 1068 1068 * A7 01 04 80 same as AT+BAUDR=115200 ... ... @@ -1072,96 +1072,99 @@ 1072 1072 A7 03 aa: Same as AT+STOPBIT=aa (aa value: 00 , 01 or 02) 1073 1073 1074 1074 1070 +==== Control output power duration ==== 1075 1075 1076 -==== **Control output power duration** ==== 1077 - 1078 1078 User can set the output power duration before each sampling. 1079 1079 1080 -* **AT Command:**1074 +* AT Command: 1081 1081 1082 - **Example:**1076 +Example: 1083 1083 1084 - **AT+3V3T=1000**~/~/ 3V3 output power will open 1s before each sampling.1078 +AT+3V3T=1000 ~/~/ 3V3 output power will open 1s before each sampling. 1085 1085 1086 - **AT+5VT=1000**~/~/ +5V output power will open 1s before each sampling.1080 +AT+5VT=1000 ~/~/ +5V output power will open 1s before each sampling. 1087 1087 1088 1088 1089 -* **LoRaWAN Downlink Command:**1083 +* LoRaWAN Downlink Command: 1090 1090 1091 - **07 01 aa bb**Same as AT+5VT=(aa bb)1085 +07 01 aa bb Same as AT+5VT=(aa bb) 1092 1092 1093 - **07 02 aa bb**Same as AT+3V3T=(aa bb)1087 +07 02 aa bb Same as AT+3V3T=(aa bb) 1094 1094 1095 1095 1096 -== 3.6 Buttons == 1097 1097 1098 -(% border="1" style="background-color:#ffffcc; color:green; width:233px" %) 1099 -|=(% style="width: 89px;" %)**Button**|=(% style="width: 141px;" %)**Feature** 1100 -|(% style="width:89px" %)**RST**|(% style="width:141px" %)Reboot RS485-BL 1101 1101 1102 -== 3.7 +3V3 Output == 1092 +1. 1093 +11. Buttons 1103 1103 1095 +|**Button**|**Feature** 1096 +|**RST**|Reboot RS485-BL 1097 + 1098 +1. 1099 +11. +3V3 Output 1100 + 1104 1104 RS485-BL has a Controllable +3V3 output, user can use this output to power external sensor. 1105 1105 1106 1106 The +3V3 output will be valid for every sampling. RS485-BL will enable +3V3 output before all sampling and disable the +3V3 after all sampling. 1107 1107 1105 + 1108 1108 The +3V3 output time can be controlled by AT Command. 1109 1109 1108 +**AT+3V3T=1000** 1110 1110 1111 -(% style="color:#037691" %)**AT+3V3T=1000** 1112 - 1113 - 1114 1114 Means set +3v3 valid time to have 1000ms. So, the real +3v3 output will actually have 1000ms + sampling time for other sensors. 1115 1115 1112 + 1116 1116 By default, the AT+3V3T=0. This is a special case, means the +3V3 output is always on at any time 1117 1117 1118 1118 1119 -== 3.8 +5V Output == 1116 +1. 1117 +11. +5V Output 1120 1120 1121 1121 RS485-BL has a Controllable +5V output, user can use this output to power external sensor. 1122 1122 1123 1123 The +5V output will be valid for every sampling. RS485-BL will enable +5V output before all sampling and disable the +5v after all sampling. 1124 1124 1123 + 1125 1125 The 5V output time can be controlled by AT Command. 1126 1126 1126 +**AT+5VT=1000** 1127 1127 1128 -(% style="color:#037691" %)**AT+5VT=1000** 1129 - 1130 - 1131 1131 Means set 5V valid time to have 1000ms. So, the real 5V output will actually have 1000ms + sampling time for other sensors. 1132 1132 1130 + 1133 1133 By default, the AT+5VT=0. If the external sensor which require 5v and require more time to get stable state, user can use this command to increase the power ON duration for this sensor. 1134 1134 1135 1135 1136 -== 3.9 LEDs == 1137 1137 1138 -(% border="1" style="background-color:#ffffcc; color:green; width:332px" %) 1139 -|=**LEDs**|=(% style="width: 274px;" %)**Feature** 1140 -|**LED1**|(% style="width:274px" %)Blink when device transmit a packet. 1141 1141 1136 +1. 1137 +11. LEDs 1142 1142 1143 -== 3.10 Switch Jumper == 1139 +|**LEDs**|**Feature** 1140 +|**LED1**|Blink when device transmit a packet. 1144 1144 1145 -(% border="1" style="background-color:#ffffcc; color:green; width:515px" %) 1146 -|=(% style="width: 124px;" %)**Switch Jumper**|=(% style="width: 388px;" %)**Feature** 1147 -|(% style="width:124px" %)**SW1**|(% style="width:388px" %)((( 1142 +1. 1143 +11. Switch Jumper 1144 + 1145 +|**Switch Jumper**|**Feature** 1146 +|**SW1**|((( 1148 1148 ISP position: Upgrade firmware via UART 1149 1149 1150 1150 Flash position: Configure device, check running status. 1151 1151 ))) 1152 -| (% style="width:124px" %)**SW2**|(% style="width:388px" %)(((1151 +|**SW2**|((( 1153 1153 5V position: set to compatible with 5v I/O. 1154 1154 1155 1155 3.3v position: set to compatible with 3.3v I/O., 1156 1156 ))) 1157 1157 1158 - **+3.3V**: is always ON1157 ++3.3V: is always ON 1159 1159 1160 - **+5V**: Only open before every sampling. The time is by default, it is AT+5VT=0. Max open time. 5000 ms.1159 ++5V: Only open before every sampling. The time is by default, it is AT+5VT=0. Max open time. 5000 ms. 1161 1161 1161 +1. Case Study 1162 1162 1163 -= 4. Case Study = 1164 - 1165 1165 User can check this URL for some case studies. 1166 1166 1167 1167 [[http:~~/~~/wiki.dragino.com/index.php?title=APP_RS485_COMMUNICATE_WITH_SENSORS>>url:http://wiki.dragino.com/index.php?title=APP_RS485_COMMUNICATE_WITH_SENSORS]] ... ... @@ -1187,7 +1187,7 @@ 1187 1187 1188 1188 1189 1189 1190 -1. 1188 +1. 1191 1191 11. Common AT Command Sequence 1192 1192 111. Multi-channel ABP mode (Use with SX1301/LG308) 1193 1193 ... ... @@ -1206,8 +1206,8 @@ 1206 1206 1207 1207 ATZ 1208 1208 1209 -1. 1210 -11. 1207 +1. 1208 +11. 1211 1211 111. Single-channel ABP mode (Use with LG01/LG02) 1212 1212 1213 1213 AT+FDR Reset Parameters to Factory Default, Keys Reserve ... ... @@ -1282,7 +1282,7 @@ 1282 1282 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image035.png]] [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image036.png]] 1283 1283 1284 1284 1285 -1. 1283 +1. 1286 1286 11. How to change the LoRa Frequency Bands/Region? 1287 1287 1288 1288 User can follow the introduction for [[how to upgrade image>>path:#upgrade_image]]. When download the images, choose the required image file for download. ... ... @@ -1289,7 +1289,7 @@ 1289 1289 1290 1290 1291 1291 1292 -1. 1290 +1. 1293 1293 11. How many RS485-Slave can RS485-BL connects? 1294 1294 1295 1295 The RS485-BL can support max 32 RS485 devices. Each uplink command of RS485-BL can support max 16 different RS485 command. So RS485-BL can support max 16 RS485 devices pre-program in the device for uplink. For other devices no pre-program, user can use the [[downlink message (type code 0xA8) to poll their info>>path:#downlink_A8]]. ... ... @@ -1306,7 +1306,7 @@ 1306 1306 1307 1307 1308 1308 1309 -1. 1307 +1. 1310 1310 11. Why I can’t join TTN V3 in US915 /AU915 bands? 1311 1311 1312 1312 It might about the channels mapping. Please see for detail.