... ... @@ -1139,7 +1139,6 @@
1139 1139  |=**LEDs**|=(% style="width: 274px;" %)**Feature**
1140 1140  |**LED1**|(% style="width:274px" %)Blink when device transmit a packet.
1141 1141  
1142 -
1143 1143  == 3.10 Switch Jumper ==
1144 1144  
1145 1145  (% border="1" style="background-color:#ffffcc; color:green; width:515px" %)
... ... @@ -1160,89 +1160,101 @@
1160 1160  **+5V**: Only open before every sampling. The time is by default, it is AT+5VT=0.  Max open time. 5000 ms.
1161 1161  
1162 1162  
1163 -1. Case Study
1162 += 4. Case Study =
1164 1164  
1165 -User can check this URL for some case studies.
1164 +User can check this URL for some case studies: [[APP RS485 COMMUNICATE WITH SENSORS>>doc:Main.Application Note \: Communicate with Different Sensors ----- RS485-LN RS485-BL.WebHome]]
1166 1166  
1167 -[[http:~~/~~/wiki.dragino.com/index.php?title=APP_RS485_COMMUNICATE_WITH_SENSORS>>url:http://wiki.dragino.com/index.php?title=APP_RS485_COMMUNICATE_WITH_SENSORS]]
1168 1168  
1167 += 5. Use AT Command =
1169 1169  
1169 +== 5.1 Access AT Command ==
1170 1170  
1171 -
1172 -1. Use AT Command
1173 -11. Access AT Command
1174 -
1175 1175  RS485-BL supports AT Command set. User can use a USB to TTL adapter plus the 3.5mm Program Cable to connect to RS485-BL to use AT command, as below.
1176 1176  
1177 -[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image027.png]]
1173 +[[image:1654135840598-282.png]]
1178 1178  
1179 1179  
1180 -In PC, User needs to set **serial tool**(such as [[putty>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to **9600** to access to access serial console of RS485-BL. The default password is 123456. Below is the output for reference:
1176 +In PC, User needs to set (% style="color:blue" %)**serial tool**(%%)(such as [[putty>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to (% style="color:green" %)**9600**(%%) to access to access serial console of RS485-BL. The default password is 123456. Below is the output for reference:
1181 1181  
1182 -[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image028.png]]
1178 +[[image:1654136105500-922.png]]
1183 1183  
1184 1184  
1181 +More detail AT Command manual can be found at [[AT Command Manual>>||anchor="3.5ConfigureRS485-BLviaATorDownlink"]]
1185 1185  
1186 -More detail AT Command manual can be found at [[AT Command Manual>>path:#AT_COMMAND]]
1187 1187  
1184 +== 5.2 Common AT Command Sequence ==
1188 1188  
1186 +=== 5.2.1 Multi-channel ABP mode (Use with SX1301/LG308) ===
1189 1189  
1190 -1.
1191 -11. Common AT Command Sequence
1192 -111. Multi-channel ABP mode (Use with SX1301/LG308)
1193 -
1194 1194  If device has not joined network yet:
1195 1195  
1196 -AT+FDR
1190 +(% class="box infomessage" %)
1191 +(((
1192 +**AT+FDR**
1193 +)))
1197 1197  
1198 -AT+NJM=0
1195 +(% class="box infomessage" %)
1196 +(((
1197 +**AT+NJM=0**
1198 +)))
1199 1199  
1200 -ATZ
1200 +(% class="box infomessage" %)
1201 +(((
1202 +**ATZ**
1203 +)))
1201 1201  
1202 1202  
1203 1203  If device already joined network:
1204 1204  
1205 -AT+NJM=0
1208 +(% class="box infomessage" %)
1209 +(((
1210 +**AT+NJM=0**
1211 +)))
1206 1206  
1207 -ATZ
1213 +(% class="box infomessage" %)
1214 +(((
1215 +**ATZ**
1216 +)))
1208 1208  
1209 -1.
1210 -11.
1211 -111. Single-channel ABP mode (Use with LG01/LG02)
1212 1212  
1213 -AT+FDR   Reset Parameters to Factory Default, Keys Reserve
1219 +=== 5.5.2 Single-channel ABP mode (Use with LG01/LG02) ===
1214 1214  
1215 -AT+NJM=0 Set to ABP mode
1216 1216  
1217 -AT+ADR=0 Set the Adaptive Data Rate Off
1222 +(% style="background-color:#dcdcdc" %)**AT+FDR** (%%) Reset Parameters to Factory Default, Keys Reserve
1218 1218  
1219 -AT+DR= Set Data Rate
1224 +(% style="background-color:#dcdcdc" %)**AT+NJM=0 **(%%)Set to ABP mode
1220 1220  
1221 -AT+TDC=60000  Set transmit interval to 60 seconds
1226 +(% style="background-color:#dcdcdc" %)**AT+ADR=0** (%%)Set the Adaptive Data Rate Off
1222 1222  
1223 -AT+CHS=868400000 Set transmit frequency to 868.4Mhz
1228 +(% style="background-color:#dcdcdc" %)**AT+DR=5**  (%%)Set Data Rate
1224 1224  
1225 -AT+RX2FQ=868400000 Set RX2Frequency to 868.4Mhz (according to the result from server)
1230 +(% style="background-color:#dcdcdc" %)**AT+TDC=60000** (%%) Set transmit interval to 60 seconds
1226 1226  
1227 -AT+RX2DR= Set RX2DR to match the downlink DR from server. see below
1232 +(% style="background-color:#dcdcdc" %)**AT+CHS=868400000**(%%) Set transmit frequency to 868.4Mhz
1228 1228  
1229 -AT+DADDR=26 01 1A F1 Set Device Address to 26 01 1A F1, this ID can be found in the LoRa Server portal.
1234 +(% style="background-color:#dcdcdc" %)**AT+RX2FQ=868400000** (%%) Set RX2Frequency to 868.4Mhz (according to the result from server)
1230 1230  
1231 -ATZ          Reset MCU
1236 +(% style="background-color:#dcdcdc" %)**AT+RX2DR=5**  (%%) Set RX2DR to match the downlink DR from server. see below
1232 1232  
1233 -**Note:**
1238 +(% style="background-color:#dcdcdc" %)**AT+DADDR=26** (%%) 01 1A F1 Set Device Address to 26 01 1A F1, this ID can be found in the LoRa Server portal.
1234 1234  
1235 -1. Make sure the device is set to ABP mode in the IoT Server.
1236 -1. Make sure the LG01/02 gateway RX frequency is exactly the same as AT+CHS setting.
1237 -1. Make sure SF / bandwidth setting in LG01/LG02 match the settings of AT+DR. refer [[this link>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/&file=LoRaWAN%201.0.3%20Regional%20Parameters.xlsx]] to see what DR means.
1238 -1. The command AT+RX2FQ and AT+RX2DR is to let downlink work. to set the correct parameters, user can check the actually downlink parameters to be used. As below. Which shows the RX2FQ should use 868400000 and RX2DR should be 5
1240 +(% style="background-color:#dcdcdc" %)**ATZ**       (%%) Reset MCU
1239 1239  
1240 -[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image029.png]]
1241 1241  
1243 +(% style="color:red" %)**Note:**
1242 1242  
1243 -1. FAQ
1244 -11. How to upgrade the image?
1245 +(% style="color:red" %)1. Make sure the device is set to ABP mode in the IoT Server.
1246 +2. Make sure the LG01/02 gateway RX frequency is exactly the same as AT+CHS setting.
1247 +3. Make sure SF / bandwidth setting in LG01/LG02 match the settings of AT+DR. refer [[this link>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/&file=LoRaWAN%201.0.3%20Regional%20Parameters.xlsx]] to see what DR means.
1248 +4. The command AT+RX2FQ and AT+RX2DR is to let downlink work. to set the correct parameters, user can check the actually downlink parameters to be used. As below. Which shows the RX2FQ should use 868400000 and RX2DR should be 5
1245 1245  
1250 +[[image:1654136435598-589.png]]
1251 +
1252 +
1253 += 6. FAQ =
1254 +
1255 +== 6.1 How to upgrade the image? ==
1256 +
1246 1246  The RS485-BL LoRaWAN Controller is shipped with a 3.5mm cable, the cable is used to upload image to RS485-BL to:
1247 1247  
1248 1248  * Support new features
... ... @@ -1251,7 +1251,7 @@
1251 1251  
1252 1252  Below shows the hardware connection for how to upload an image to RS485-BL:
1253 1253  
1254 -[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image030.png]]
1265 +[[image:1654136646995-976.png]]
1255 1255  
1256 1256  **Step1:** Download [[flash loader>>url:https://www.st.com/content/st_com/en/products/development-tools/software-development-tools/stm32-software-development-tools/stm32-programmers/flasher-stm32.html]].
1257 1257  
... ... @@ -1282,7 +1282,7 @@
1282 1282  [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image035.png]] [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image036.png]]
1283 1283  
1284 1284  
1285 -1.
1296 +1.
1286 1286  11. How to change the LoRa Frequency Bands/Region?
1287 1287  
1288 1288  User can follow the introduction for [[how to upgrade image>>path:#upgrade_image]]. When download the images, choose the required image file for download.
... ... @@ -1289,7 +1289,7 @@
1289 1289  
1290 1290  
1291 1291  
1292 -1.
1303 +1.
1293 1293  11. How many RS485-Slave can RS485-BL connects?
1294 1294  
1295 1295  The RS485-BL can support max 32 RS485 devices. Each uplink command of RS485-BL can support max 16 different RS485 command. So RS485-BL can support max 16 RS485 devices pre-program in the device for uplink. For other devices no pre-program, user can use the [[downlink message (type code 0xA8) to poll their info>>path:#downlink_A8]].
... ... @@ -1306,7 +1306,7 @@
1306 1306  
1307 1307  
1308 1308  
1309 -1.
1320 +1.
1310 1310  11. Why I can’t join TTN V3 in US915 /AU915 bands?
1311 1311  
1312 1312  It might about the channels mapping. Please see for detail.
1654135840598-282.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +1.3 MB
Content
1654136105500-922.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +203.7 KB
Content
1654136435598-589.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +158.9 KB
Content
1654136646995-976.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +1.3 MB
Content
image-20220602102605-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +102.6 KB
Content