... ... @@ -1139,108 +1139,121 @@
1139 1139  |=**LEDs**|=(% style="width: 274px;" %)**Feature**
1140 1140  |**LED1**|(% style="width:274px" %)Blink when device transmit a packet.
1141 1141  
1142 -
1143 1143  == 3.10 Switch Jumper ==
1144 1144  
1145 -|**Switch Jumper**|**Feature**
1146 -|**SW1**|(((
1144 +(% border="1" style="background-color:#ffffcc; color:green; width:515px" %)
1145 +|=(% style="width: 124px;" %)**Switch Jumper**|=(% style="width: 388px;" %)**Feature**
1146 +|(% style="width:124px" %)**SW1**|(% style="width:388px" %)(((
1147 1147  ISP position: Upgrade firmware via UART
1148 1148  
1149 1149  Flash position: Configure device, check running status.
1150 1150  )))
1151 -|**SW2**|(((
1151 +|(% style="width:124px" %)**SW2**|(% style="width:388px" %)(((
1152 1152  5V position: set to compatible with 5v I/O.
1153 1153  
1154 1154  3.3v position: set to compatible with 3.3v I/O.,
1155 1155  )))
1156 1156  
1157 -+3.3V: is always ON
1157 +**+3.3V**: is always ON
1158 1158  
1159 -+5V: Only open before every sampling. The time is by default, it is AT+5VT=0.  Max open time. 5000 ms.
1159 +**+5V**: Only open before every sampling. The time is by default, it is AT+5VT=0.  Max open time. 5000 ms.
1160 1160  
1161 -1. Case Study
1162 1162  
1163 -User can check this URL for some case studies.
1162 += 4. Case Study =
1164 1164  
1165 -[[http:~~/~~/wiki.dragino.com/index.php?title=APP_RS485_COMMUNICATE_WITH_SENSORS>>url:http://wiki.dragino.com/index.php?title=APP_RS485_COMMUNICATE_WITH_SENSORS]]
1164 +User can check this URL for some case studies: [[APP RS485 COMMUNICATE WITH SENSORS>>doc:Main.Application Note \: Communicate with Different Sensors ----- RS485-LN RS485-BL.WebHome]]
1166 1166  
1167 1167  
1167 += 5. Use AT Command =
1168 1168  
1169 +== 5.1 Access AT Command ==
1169 1169  
1170 -1. Use AT Command
1171 -11. Access AT Command
1172 -
1173 1173  RS485-BL supports AT Command set. User can use a USB to TTL adapter plus the 3.5mm Program Cable to connect to RS485-BL to use AT command, as below.
1174 1174  
1175 -[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image027.png]]
1173 +[[image:1654135840598-282.png]]
1176 1176  
1177 1177  
1178 -In PC, User needs to set **serial tool**(such as [[putty>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to **9600** to access to access serial console of RS485-BL. The default password is 123456. Below is the output for reference:
1176 +In PC, User needs to set (% style="color:blue" %)**serial tool**(%%)(such as [[putty>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to (% style="color:green" %)**9600**(%%) to access to access serial console of RS485-BL. The default password is 123456. Below is the output for reference:
1179 1179  
1180 -[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image028.png]]
1178 +[[image:1654136105500-922.png]]
1181 1181  
1182 1182  
1181 +More detail AT Command manual can be found at [[AT Command Manual>>||anchor="3.5ConfigureRS485-BLviaATorDownlink"]]
1183 1183  
1184 -More detail AT Command manual can be found at [[AT Command Manual>>path:#AT_COMMAND]]
1185 1185  
1184 +== 5.2 Common AT Command Sequence ==
1186 1186  
1186 +=== 5.2.1 Multi-channel ABP mode (Use with SX1301/LG308) ===
1187 1187  
1188 -1.
1189 -11. Common AT Command Sequence
1190 -111. Multi-channel ABP mode (Use with SX1301/LG308)
1191 -
1192 1192  If device has not joined network yet:
1193 1193  
1194 -AT+FDR
1190 +(% class="box infomessage" %)
1191 +(((
1192 +**AT+FDR**
1193 +)))
1195 1195  
1196 -AT+NJM=0
1195 +(% class="box infomessage" %)
1196 +(((
1197 +**AT+NJM=0**
1198 +)))
1197 1197  
1198 -ATZ
1200 +(% class="box infomessage" %)
1201 +(((
1202 +**ATZ**
1203 +)))
1199 1199  
1200 1200  
1201 1201  If device already joined network:
1202 1202  
1203 -AT+NJM=0
1208 +(% class="box infomessage" %)
1209 +(((
1210 +**AT+NJM=0**
1211 +)))
1204 1204  
1205 -ATZ
1213 +(% class="box infomessage" %)
1214 +(((
1215 +**ATZ**
1216 +)))
1206 1206  
1207 -1.
1208 -11.
1209 -111. Single-channel ABP mode (Use with LG01/LG02)
1210 1210  
1211 -AT+FDR   Reset Parameters to Factory Default, Keys Reserve
1219 +=== 5.5.2 Single-channel ABP mode (Use with LG01/LG02) ===
1212 1212  
1213 -AT+NJM=0 Set to ABP mode
1214 1214  
1215 -AT+ADR=0 Set the Adaptive Data Rate Off
1222 +(% style="background-color:#dcdcdc" %)**AT+FDR** (%%) Reset Parameters to Factory Default, Keys Reserve
1216 1216  
1217 -AT+DR= Set Data Rate
1224 +(% style="background-color:#dcdcdc" %)**AT+NJM=0 **(%%)Set to ABP mode
1218 1218  
1219 -AT+TDC=60000  Set transmit interval to 60 seconds
1226 +(% style="background-color:#dcdcdc" %)**AT+ADR=0** (%%)Set the Adaptive Data Rate Off
1220 1220  
1221 -AT+CHS=868400000 Set transmit frequency to 868.4Mhz
1228 +(% style="background-color:#dcdcdc" %)**AT+DR=5**  (%%)Set Data Rate
1222 1222  
1223 -AT+RX2FQ=868400000 Set RX2Frequency to 868.4Mhz (according to the result from server)
1230 +(% style="background-color:#dcdcdc" %)**AT+TDC=60000** (%%) Set transmit interval to 60 seconds
1224 1224  
1225 -AT+RX2DR= Set RX2DR to match the downlink DR from server. see below
1232 +(% style="background-color:#dcdcdc" %)**AT+CHS=868400000**(%%) Set transmit frequency to 868.4Mhz
1226 1226  
1227 -AT+DADDR=26 01 1A F1 Set Device Address to 26 01 1A F1, this ID can be found in the LoRa Server portal.
1234 +(% style="background-color:#dcdcdc" %)**AT+RX2FQ=868400000** (%%) Set RX2Frequency to 868.4Mhz (according to the result from server)
1228 1228  
1229 -ATZ          Reset MCU
1236 +(% style="background-color:#dcdcdc" %)**AT+RX2DR=5**  (%%) Set RX2DR to match the downlink DR from server. see below
1230 1230  
1231 -**Note:**
1238 +(% style="background-color:#dcdcdc" %)**AT+DADDR=26** (%%) 01 1A F1 Set Device Address to 26 01 1A F1, this ID can be found in the LoRa Server portal.
1232 1232  
1233 -1. Make sure the device is set to ABP mode in the IoT Server.
1234 -1. Make sure the LG01/02 gateway RX frequency is exactly the same as AT+CHS setting.
1235 -1. Make sure SF / bandwidth setting in LG01/LG02 match the settings of AT+DR. refer [[this link>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/&file=LoRaWAN%201.0.3%20Regional%20Parameters.xlsx]] to see what DR means.
1236 -1. The command AT+RX2FQ and AT+RX2DR is to let downlink work. to set the correct parameters, user can check the actually downlink parameters to be used. As below. Which shows the RX2FQ should use 868400000 and RX2DR should be 5
1240 +(% style="background-color:#dcdcdc" %)**ATZ**       (%%) Reset MCU
1237 1237  
1238 -[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image029.png]]
1239 1239  
1243 +(% style="color:red" %)**Note:**
1240 1240  
1241 -1. FAQ
1242 -11. How to upgrade the image?
1245 +(% style="color:red" %)1. Make sure the device is set to ABP mode in the IoT Server.
1246 +2. Make sure the LG01/02 gateway RX frequency is exactly the same as AT+CHS setting.
1247 +3. Make sure SF / bandwidth setting in LG01/LG02 match the settings of AT+DR. refer [[this link>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/&file=LoRaWAN%201.0.3%20Regional%20Parameters.xlsx]] to see what DR means.
1248 +4. The command AT+RX2FQ and AT+RX2DR is to let downlink work. to set the correct parameters, user can check the actually downlink parameters to be used. As below. Which shows the RX2FQ should use 868400000 and RX2DR should be 5
1243 1243  
1250 +[[image:1654136435598-589.png]]
1251 +
1252 +
1253 += 6. FAQ =
1254 +
1255 +== 6.1 How to upgrade the image? ==
1256 +
1244 1244  The RS485-BL LoRaWAN Controller is shipped with a 3.5mm cable, the cable is used to upload image to RS485-BL to:
1245 1245  
1246 1246  * Support new features
... ... @@ -1249,7 +1249,7 @@
1249 1249  
1250 1250  Below shows the hardware connection for how to upload an image to RS485-BL:
1251 1251  
1252 -[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image030.png]]
1265 +[[image:1654136646995-976.png]]
1253 1253  
1254 1254  **Step1:** Download [[flash loader>>url:https://www.st.com/content/st_com/en/products/development-tools/software-development-tools/stm32-software-development-tools/stm32-programmers/flasher-stm32.html]].
1255 1255  
... ... @@ -1257,81 +1257,61 @@
1257 1257  
1258 1258  **Step3: **Open flashloader; choose the correct COM port to update.
1259 1259  
1273 +[[image:image-20220602102605-1.png]]
1260 1260  
1261 -|(((
1262 -HOLD PRO then press the RST button, SYS will be ON, then click next
1263 -)))
1264 1264  
1265 -|(((
1266 -Board detected
1267 -)))
1276 +[[image:image-20220602102637-2.png]]
1268 1268  
1269 -|(((
1270 -
1271 -)))
1272 1272  
1273 -[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image031.png]] [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image032.png]]
1279 +[[image:image-20220602102715-3.png]]
1274 1274  
1275 1275  
1276 1276  
1277 -[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image033.png]] [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image034.png]]
1283 +== 6.2 How to change the LoRa Frequency Bands/Region? ==
1278 1278  
1285 +User can follow the introduction for [[how to upgrade image>>||anchor="H6.1Howtoupgradetheimage3F"]]. When download the images, choose the required image file for download.
1279 1279  
1280 -[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image035.png]] [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image036.png]]
1281 1281  
1282 1282  
1283 -1.
1284 -11. How to change the LoRa Frequency Bands/Region?
1289 +== 6.3 How many RS485-Slave can RS485-BL connects? ==
1285 1285  
1286 -User can follow the introduction for [[how to upgrade image>>path:#upgrade_image]]. When download the images, choose the required image file for download.
1291 +The RS485-BL can support max 32 RS485 devices. Each uplink command of RS485-BL can support max 16 different RS485 command. So RS485-BL can support max 16 RS485 devices pre-program in the device for uplink. For other devices no pre-program, user can use the [[downlink message (type code 0xA8) to poll their info>>||anchor="H3.3.3Configurereadcommandsforeachsampling"]].
1287 1287  
1288 1288  
1289 1289  
1290 -1.
1291 -11. How many RS485-Slave can RS485-BL connects?
1295 += 7. Trouble Shooting =
1292 1292  
1293 -The RS485-BL can support max 32 RS485 devices. Each uplink command of RS485-BL can support max 16 different RS485 command. So RS485-BL can support max 16 RS485 devices pre-program in the device for uplink. For other devices no pre-program, user can use the [[downlink message (type code 0xA8) to poll their info>>path:#downlink_A8]].
1294 1294  
1298 +== 7.1 Downlink doesn’t work, how to solve it? ==
1295 1295  
1300 +Please see this link for debug: [[LoRaWAN Communication Debug>>doc:Main.LoRaWAN Communication Debug.WebHome]]
1296 1296  
1297 1297  
1298 -1. Trouble Shooting     
1299 -11. Downlink doesn’t work, how to solve it?
1303 +== 7.2 Why I can’t join TTN V3 in US915 /AU915 bands? ==
1300 1300  
1301 -Please see this link for debug:
1305 +It might about the channels mapping. Please see for detail: [[Notice of Frequency band>>doc:Main.LoRaWAN Communication Debug.WebHome||anchor="H2.NoticeofUS9152FCN4702FAU915Frequencyband"]]
1302 1302  
1303 -[[http:~~/~~/wiki.dragino.com/index.php?title=Main_Page#LoRaWAN_Communication_Debug>>url:http://wiki.dragino.com/index.php?title=Main_Page#LoRaWAN_Communication_Debug]] 
1304 1304  
1308 += 8. Order Info =
1305 1305  
1310 +(% style="color:bule" %)**Part Number: RS485-BL-XXX**
1306 1306  
1307 -1.
1308 -11. Why I can’t join TTN V3 in US915 /AU915 bands?
1312 +(% style="color:bule" %)**XXX:**
1309 1309  
1310 -It might about the channels mapping. Please see for detail.
1314 +* (% style="color:bule" %)**EU433**(%%): frequency bands EU433
1315 +* (% style="color:bule" %)**EU868**(%%): frequency bands EU868
1316 +* (% style="color:bule" %)**KR920**(%%): frequency bands KR920
1317 +* (% style="color:bule" %)**CN470**(%%): frequency bands CN470
1318 +* (% style="color:bule" %)**AS923**(%%): frequency bands AS923
1319 +* (% style="color:bule" %)**AU915**(%%): frequency bands AU915
1320 +* (% style="color:bule" %)**US915**(%%): frequency bands US915
1321 +* (% style="color:bule" %)**IN865**(%%): frequency bands IN865
1322 +* (% style="color:bule" %)**RU864**(%%): frequency bands RU864
1323 +* (% style="color:bule" %)**KZ865**(%%): frequency bands KZ865
1311 1311  
1312 -[[http:~~/~~/wiki.dragino.com/index.php?title=LoRaWAN_Communication_Debug#Notice_of_US915.2FCN470.2FAU915_Frequency_band>>url:http://wiki.dragino.com/index.php?title=LoRaWAN_Communication_Debug#Notice_of_US915.2FCN470.2FAU915_Frequency_band]]
1313 1313  
1326 += 9. Packing Info =
1314 1314  
1315 -
1316 -1. Order Info
1317 -
1318 -**Part Number: RS485-BL-XXX**
1319 -
1320 -**XXX:**
1321 -
1322 -* **EU433**: frequency bands EU433
1323 -* **EU868**: frequency bands EU868
1324 -* **KR920**: frequency bands KR920
1325 -* **CN470**: frequency bands CN470
1326 -* **AS923**: frequency bands AS923
1327 -* **AU915**: frequency bands AU915
1328 -* **US915**: frequency bands US915
1329 -* **IN865**: frequency bands IN865
1330 -* **RU864**: frequency bands RU864
1331 -* **KZ865: **frequency bands KZ865
1332 -
1333 -1. Packing Info
1334 -
1335 1335  **Package Includes**:
1336 1336  
1337 1337  * RS485-BL x 1
... ... @@ -1345,8 +1345,9 @@
1345 1345  * Package Size / pcs : 14.5 x 8 x 5 cm
1346 1346  * Weight / pcs : 170g
1347 1347  
1348 -1. Support
1349 1349  
1342 += 10. Support =
1343 +
1350 1350  * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
1351 1351  * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to
1352 1352  
1654135840598-282.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +1.3 MB
Content
1654136105500-922.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +203.7 KB
Content
1654136435598-589.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +158.9 KB
Content
1654136646995-976.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +1.3 MB
Content
image-20220602102605-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +102.6 KB
Content
image-20220602102637-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +250.8 KB
Content
image-20220602102715-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +176.2 KB
Content