Changes for page RS485-BL – Waterproof RS485 to LoRaWAN Converter
Last modified by Xiaoling on 2025/04/23 15:57
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 2 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1139,97 +1139,108 @@ 1139 1139 |=**LEDs**|=(% style="width: 274px;" %)**Feature** 1140 1140 |**LED1**|(% style="width:274px" %)Blink when device transmit a packet. 1141 1141 1142 - 1143 1143 == 3.10 Switch Jumper == 1144 1144 1145 -|**Switch Jumper**|**Feature** 1146 -|**SW1**|((( 1144 +(% border="1" style="background-color:#ffffcc; color:green; width:515px" %) 1145 +|=(% style="width: 124px;" %)**Switch Jumper**|=(% style="width: 388px;" %)**Feature** 1146 +|(% style="width:124px" %)**SW1**|(% style="width:388px" %)((( 1147 1147 ISP position: Upgrade firmware via UART 1148 1148 1149 1149 Flash position: Configure device, check running status. 1150 1150 ))) 1151 -|**SW2**|((( 1151 +|(% style="width:124px" %)**SW2**|(% style="width:388px" %)((( 1152 1152 5V position: set to compatible with 5v I/O. 1153 1153 1154 1154 3.3v position: set to compatible with 3.3v I/O., 1155 1155 ))) 1156 1156 1157 -+3.3V: is always ON 1157 +**+3.3V**: is always ON 1158 1158 1159 -+5V: Only open before every sampling. The time is by default, it is AT+5VT=0. Max open time. 5000 ms. 1159 +**+5V**: Only open before every sampling. The time is by default, it is AT+5VT=0. Max open time. 5000 ms. 1160 1160 1161 -1. Case Study 1162 1162 1163 - Usercancheck this URL for some casestudies.1162 += 4. Case Study = 1164 1164 1165 - [[http:~~/~~/wiki.dragino.com/index.php?title=APP_RS485_COMMUNICATE_WITH_SENSORS>>url:http://wiki.dragino.com/index.php?title=APP_RS485_COMMUNICATE_WITH_SENSORS]]1164 +User can check this URL for some case studies: [[APP RS485 COMMUNICATE WITH SENSORS>>doc:Main.Application Note \: Communicate with Different Sensors ----- RS485-LN RS485-BL.WebHome]] 1166 1166 1167 1167 1167 += 5. Use AT Command = 1168 1168 1169 +== 5.1 Access AT Command == 1169 1169 1170 -1. Use AT Command 1171 -11. Access AT Command 1172 - 1173 1173 RS485-BL supports AT Command set. User can use a USB to TTL adapter plus the 3.5mm Program Cable to connect to RS485-BL to use AT command, as below. 1174 1174 1175 -[[image: file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image027.png]]1173 +[[image:1654135840598-282.png]] 1176 1176 1177 1177 1178 -In PC, User needs to set **serial tool**(such as [[putty>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to **9600** to access to access serial console of RS485-BL. The default password is 123456. Below is the output for reference: 1176 +In PC, User needs to set (% style="color:blue" %)**serial tool**(%%)(such as [[putty>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to (% style="color:green" %)**9600**(%%) to access to access serial console of RS485-BL. The default password is 123456. Below is the output for reference: 1179 1179 1180 -[[image: file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image028.png]]1178 +[[image:1654136105500-922.png]] 1181 1181 1182 1182 1181 +More detail AT Command manual can be found at [[AT Command Manual>>||anchor="3.5ConfigureRS485-BLviaATorDownlink"]] 1183 1183 1184 -More detail AT Command manual can be found at [[AT Command Manual>>path:#AT_COMMAND]] 1185 1185 1184 +== 5.2 Common AT Command Sequence == 1186 1186 1186 +=== 5.2.1 Multi-channel ABP mode (Use with SX1301/LG308) === 1187 1187 1188 -1. 1189 -11. Common AT Command Sequence 1190 -111. Multi-channel ABP mode (Use with SX1301/LG308) 1191 - 1192 1192 If device has not joined network yet: 1193 1193 1194 -AT+FDR 1190 +(% class="box infomessage" %) 1191 +((( 1192 +**AT+FDR** 1193 +))) 1195 1195 1196 -AT+NJM=0 1195 +(% class="box infomessage" %) 1196 +((( 1197 +**AT+NJM=0** 1198 +))) 1197 1197 1198 -ATZ 1200 +(% class="box infomessage" %) 1201 +((( 1202 +**ATZ** 1203 +))) 1199 1199 1200 1200 1201 1201 If device already joined network: 1202 1202 1203 -AT+NJM=0 1208 +(% class="box infomessage" %) 1209 +((( 1210 +**AT+NJM=0** 1211 +))) 1204 1204 1205 -ATZ 1213 +(% class="box infomessage" %) 1214 +((( 1215 +**ATZ** 1216 +))) 1206 1206 1207 -1. 1208 -11. 1209 -111. Single-channel ABP mode (Use with LG01/LG02) 1210 1210 1211 - AT+FDRResetParameters toFactoryDefault, Keys Reserve1219 +=== 5.5.2 Single-channel ABP mode (Use with LG01/LG02) === 1212 1212 1213 -AT+NJM=0 Set to ABP mode 1214 1214 1215 -AT+ ADR=0Set theAdaptiveDataRateOff1222 +(% style="background-color:#dcdcdc" %)**AT+FDR** (%%) Reset Parameters to Factory Default, Keys Reserve 1216 1216 1217 -AT+ DR=5SetDataRate1224 +(% style="background-color:#dcdcdc" %)**AT+NJM=0 **(%%)Set to ABP mode 1218 1218 1219 -AT+ TDC=60000Set transmitntervalto60 seconds1226 +(% style="background-color:#dcdcdc" %)**AT+ADR=0** (%%)Set the Adaptive Data Rate Off 1220 1220 1221 -AT+ CHS=868400000Settransmitfrequencyto 868.4Mhz1228 +(% style="background-color:#dcdcdc" %)**AT+DR=5** (%%)Set Data Rate 1222 1222 1223 -AT+ RX2FQ=868400000SetRX2Frequencyto868.4Mhz (accordingto theesultfromserver)1230 +(% style="background-color:#dcdcdc" %)**AT+TDC=60000** (%%) Set transmit interval to 60 seconds 1224 1224 1225 -AT+ RX2DR=5SetRX2DRto match the downlinkDRfrom server.see below1232 +(% style="background-color:#dcdcdc" %)**AT+CHS=868400000**(%%) Set transmit frequency to 868.4Mhz 1226 1226 1227 -AT+ DADDR=2611AF1SetDeviceAddressto2601 1A F1, thisID can be foundLoRaServerportal.1234 +(% style="background-color:#dcdcdc" %)**AT+RX2FQ=868400000** (%%) Set RX2Frequency to 868.4Mhz (according to the result from server) 1228 1228 1229 -AT ZtMCU1236 +(% style="background-color:#dcdcdc" %)**AT+RX2DR=5** (%%) Set RX2DR to match the downlink DR from server. see below 1230 1230 1231 - **Note:**1238 +(% style="background-color:#dcdcdc" %)**AT+DADDR=26** (%%) 01 1A F1 Set Device Address to 26 01 1A F1, this ID can be found in the LoRa Server portal. 1232 1232 1240 +(% style="background-color:#dcdcdc" %)**ATZ** (%%) Reset MCU 1241 + 1242 +(% style="color:red" %)**Note:** 1243 + 1233 1233 1. Make sure the device is set to ABP mode in the IoT Server. 1234 1234 1. Make sure the LG01/02 gateway RX frequency is exactly the same as AT+CHS setting. 1235 1235 1. Make sure SF / bandwidth setting in LG01/LG02 match the settings of AT+DR. refer [[this link>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/&file=LoRaWAN%201.0.3%20Regional%20Parameters.xlsx]] to see what DR means. ... ... @@ -1280,7 +1280,7 @@ 1280 1280 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image035.png]] [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image036.png]] 1281 1281 1282 1282 1283 -1. 1294 +1. 1284 1284 11. How to change the LoRa Frequency Bands/Region? 1285 1285 1286 1286 User can follow the introduction for [[how to upgrade image>>path:#upgrade_image]]. When download the images, choose the required image file for download. ... ... @@ -1287,7 +1287,7 @@ 1287 1287 1288 1288 1289 1289 1290 -1. 1301 +1. 1291 1291 11. How many RS485-Slave can RS485-BL connects? 1292 1292 1293 1293 The RS485-BL can support max 32 RS485 devices. Each uplink command of RS485-BL can support max 16 different RS485 command. So RS485-BL can support max 16 RS485 devices pre-program in the device for uplink. For other devices no pre-program, user can use the [[downlink message (type code 0xA8) to poll their info>>path:#downlink_A8]]. ... ... @@ -1304,7 +1304,7 @@ 1304 1304 1305 1305 1306 1306 1307 -1. 1318 +1. 1308 1308 11. Why I can’t join TTN V3 in US915 /AU915 bands? 1309 1309 1310 1310 It might about the channels mapping. Please see for detail.
- 1654135840598-282.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +1.3 MB - Content
- 1654136105500-922.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +203.7 KB - Content