Last modified by Xiaoling on 2025/04/23 15:57

From version 33.7
edited by Xiaoling
on 2022/06/02 10:04
Change comment: There is no comment for this version
To version 35.2
edited by Xiaoling
on 2022/06/02 10:15
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1139,55 +1139,52 @@
1139 1139  |=**LEDs**|=(% style="width: 274px;" %)**Feature**
1140 1140  |**LED1**|(% style="width:274px" %)Blink when device transmit a packet.
1141 1141  
1142 -
1143 1143  == 3.10 Switch Jumper ==
1144 1144  
1145 -|**Switch Jumper**|**Feature**
1146 -|**SW1**|(((
1144 +(% border="1" style="background-color:#ffffcc; color:green; width:515px" %)
1145 +|=(% style="width: 124px;" %)**Switch Jumper**|=(% style="width: 388px;" %)**Feature**
1146 +|(% style="width:124px" %)**SW1**|(% style="width:388px" %)(((
1147 1147  ISP position: Upgrade firmware via UART
1148 1148  
1149 1149  Flash position: Configure device, check running status.
1150 1150  )))
1151 -|**SW2**|(((
1151 +|(% style="width:124px" %)**SW2**|(% style="width:388px" %)(((
1152 1152  5V position: set to compatible with 5v I/O.
1153 1153  
1154 1154  3.3v position: set to compatible with 3.3v I/O.,
1155 1155  )))
1156 1156  
1157 -+3.3V: is always ON
1157 +**+3.3V**: is always ON
1158 1158  
1159 -+5V: Only open before every sampling. The time is by default, it is AT+5VT=0.  Max open time. 5000 ms.
1159 +**+5V**: Only open before every sampling. The time is by default, it is AT+5VT=0.  Max open time. 5000 ms.
1160 1160  
1161 -1. Case Study
1162 1162  
1163 -User can check this URL for some case studies.
1162 += 4. Case Study =
1164 1164  
1165 -[[http:~~/~~/wiki.dragino.com/index.php?title=APP_RS485_COMMUNICATE_WITH_SENSORS>>url:http://wiki.dragino.com/index.php?title=APP_RS485_COMMUNICATE_WITH_SENSORS]]
1164 +User can check this URL for some case studies: [[APP RS485 COMMUNICATE WITH SENSORS>>doc:Main.Application Note \: Communicate with Different Sensors ----- RS485-LN RS485-BL.WebHome]]
1166 1166  
1167 1167  
1167 += 5. Use AT Command =
1168 1168  
1169 +== 5.1 Access AT Command ==
1169 1169  
1170 -1. Use AT Command
1171 -11. Access AT Command
1172 -
1173 1173  RS485-BL supports AT Command set. User can use a USB to TTL adapter plus the 3.5mm Program Cable to connect to RS485-BL to use AT command, as below.
1174 1174  
1175 -[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image027.png]]
1173 +[[image:1654135840598-282.png]]
1176 1176  
1177 1177  
1178 -In PC, User needs to set **serial tool**(such as [[putty>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to **9600** to access to access serial console of RS485-BL. The default password is 123456. Below is the output for reference:
1176 +In PC, User needs to set (% style="color:blue" %)**serial tool**(%%)(such as [[putty>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to (% style="color:green" %)**9600**(%%) to access to access serial console of RS485-BL. The default password is 123456. Below is the output for reference:
1179 1179  
1180 -[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image028.png]]
1178 +[[image:1654136105500-922.png]]
1181 1181  
1182 1182  
1181 +More detail AT Command manual can be found at [[AT Command Manual>>||anchor="3.5ConfigureRS485-BLviaATorDownlink"]]
1183 1183  
1184 -More detail AT Command manual can be found at [[AT Command Manual>>path:#AT_COMMAND]]
1185 1185  
1186 1186  
1185 +== 5.2 Common AT Command Sequence ==
1187 1187  
1188 -1.
1189 -11. Common AT Command Sequence
1190 -111. Multi-channel ABP mode (Use with SX1301/LG308)
1187 +=== 5.2.1 Multi-channel ABP mode (Use with SX1301/LG308) ===
1191 1191  
1192 1192  If device has not joined network yet:
1193 1193  
1654135840598-282.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +1.3 MB
Content
1654136105500-922.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +203.7 KB
Content