Changes for page RS485-BL – Waterproof RS485 to LoRaWAN Converter
Last modified by Xiaoling on 2025/04/23 15:57
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 2 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1122,113 +1122,125 @@ 1122 1122 1123 1123 The +5V output will be valid for every sampling. RS485-BL will enable +5V output before all sampling and disable the +5v after all sampling. 1124 1124 1125 - 1126 1126 The 5V output time can be controlled by AT Command. 1127 1127 1127 + 1128 1128 (% style="color:#037691" %)**AT+5VT=1000** 1129 1129 1130 + 1130 1130 Means set 5V valid time to have 1000ms. So, the real 5V output will actually have 1000ms + sampling time for other sensors. 1131 1131 1132 - 1133 1133 By default, the AT+5VT=0. If the external sensor which require 5v and require more time to get stable state, user can use this command to increase the power ON duration for this sensor. 1134 1134 1135 1135 1136 - 1137 1137 == 3.9 LEDs == 1138 1138 1139 -|**LEDs**|**Feature** 1140 -|**LED1**|Blink when device transmit a packet. 1138 +(% border="1" style="background-color:#ffffcc; color:green; width:332px" %) 1139 +|=**LEDs**|=(% style="width: 274px;" %)**Feature** 1140 +|**LED1**|(% style="width:274px" %)Blink when device transmit a packet. 1141 1141 1142 1142 == 3.10 Switch Jumper == 1143 1143 1144 -|**Switch Jumper**|**Feature** 1145 -|**SW1**|((( 1144 +(% border="1" style="background-color:#ffffcc; color:green; width:515px" %) 1145 +|=(% style="width: 124px;" %)**Switch Jumper**|=(% style="width: 388px;" %)**Feature** 1146 +|(% style="width:124px" %)**SW1**|(% style="width:388px" %)((( 1146 1146 ISP position: Upgrade firmware via UART 1147 1147 1148 1148 Flash position: Configure device, check running status. 1149 1149 ))) 1150 -|**SW2**|((( 1151 +|(% style="width:124px" %)**SW2**|(% style="width:388px" %)((( 1151 1151 5V position: set to compatible with 5v I/O. 1152 1152 1153 1153 3.3v position: set to compatible with 3.3v I/O., 1154 1154 ))) 1155 1155 1156 -+3.3V: is always ON 1157 +**+3.3V**: is always ON 1157 1157 1158 -+5V: Only open before every sampling. The time is by default, it is AT+5VT=0. Max open time. 5000 ms. 1159 +**+5V**: Only open before every sampling. The time is by default, it is AT+5VT=0. Max open time. 5000 ms. 1159 1159 1160 -1. Case Study 1161 1161 1162 - Usercancheck this URL for some casestudies.1162 += 4. Case Study = 1163 1163 1164 - [[http:~~/~~/wiki.dragino.com/index.php?title=APP_RS485_COMMUNICATE_WITH_SENSORS>>url:http://wiki.dragino.com/index.php?title=APP_RS485_COMMUNICATE_WITH_SENSORS]]1164 +User can check this URL for some case studies: [[APP RS485 COMMUNICATE WITH SENSORS>>doc:Main.Application Note \: Communicate with Different Sensors ----- RS485-LN RS485-BL.WebHome]] 1165 1165 1166 1166 1167 += 5. Use AT Command = 1167 1167 1169 +== 5.1 Access AT Command == 1168 1168 1169 -1. Use AT Command 1170 -11. Access AT Command 1171 - 1172 1172 RS485-BL supports AT Command set. User can use a USB to TTL adapter plus the 3.5mm Program Cable to connect to RS485-BL to use AT command, as below. 1173 1173 1174 -[[image: file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image027.png]]1173 +[[image:1654135840598-282.png]] 1175 1175 1176 1176 1177 -In PC, User needs to set **serial tool**(such as [[putty>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to **9600** to access to access serial console of RS485-BL. The default password is 123456. Below is the output for reference: 1176 +In PC, User needs to set (% style="color:blue" %)**serial tool**(%%)(such as [[putty>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to (% style="color:green" %)**9600**(%%) to access to access serial console of RS485-BL. The default password is 123456. Below is the output for reference: 1178 1178 1179 -[[image: file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image028.png]]1178 +[[image:1654136105500-922.png]] 1180 1180 1181 1181 1181 +More detail AT Command manual can be found at [[AT Command Manual>>||anchor="3.5ConfigureRS485-BLviaATorDownlink"]] 1182 1182 1183 -More detail AT Command manual can be found at [[AT Command Manual>>path:#AT_COMMAND]] 1184 1184 1184 +== 5.2 Common AT Command Sequence == 1185 1185 1186 +=== 5.2.1 Multi-channel ABP mode (Use with SX1301/LG308) === 1186 1186 1187 -1. 1188 -11. Common AT Command Sequence 1189 -111. Multi-channel ABP mode (Use with SX1301/LG308) 1190 - 1191 1191 If device has not joined network yet: 1192 1192 1193 -AT+FDR 1190 +(% class="box infomessage" %) 1191 +((( 1192 +**AT+FDR** 1193 +))) 1194 1194 1195 -AT+NJM=0 1195 +(% class="box infomessage" %) 1196 +((( 1197 +**AT+NJM=0** 1198 +))) 1196 1196 1197 -ATZ 1200 +(% class="box infomessage" %) 1201 +((( 1202 +**ATZ** 1203 +))) 1198 1198 1199 1199 1200 1200 If device already joined network: 1201 1201 1202 -AT+NJM=0 1208 +(% class="box infomessage" %) 1209 +((( 1210 +**AT+NJM=0** 1211 +))) 1203 1203 1204 -ATZ 1213 +(% class="box infomessage" %) 1214 +((( 1215 +**ATZ** 1216 +))) 1205 1205 1206 -1. 1207 -11. 1208 -111. Single-channel ABP mode (Use with LG01/LG02) 1209 1209 1210 - AT+FDRResetParameters toFactoryDefault, Keys Reserve1219 +=== 5.5.2 Single-channel ABP mode (Use with LG01/LG02) === 1211 1211 1212 -AT+NJM=0 Set to ABP mode 1213 1213 1214 -AT+ ADR=0Set theAdaptiveDataRateOff1222 +(% style="background-color:#dcdcdc" %)**AT+FDR** (%%) Reset Parameters to Factory Default, Keys Reserve 1215 1215 1216 -AT+ DR=5SetDataRate1224 +(% style="background-color:#dcdcdc" %)**AT+NJM=0 **(%%)Set to ABP mode 1217 1217 1218 -AT+ TDC=60000Set transmitntervalto60 seconds1226 +(% style="background-color:#dcdcdc" %)**AT+ADR=0** (%%)Set the Adaptive Data Rate Off 1219 1219 1220 -AT+ CHS=868400000Settransmitfrequencyto 868.4Mhz1228 +(% style="background-color:#dcdcdc" %)**AT+DR=5** (%%)Set Data Rate 1221 1221 1222 -AT+ RX2FQ=868400000SetRX2Frequencyto868.4Mhz (accordingto theesultfromserver)1230 +(% style="background-color:#dcdcdc" %)**AT+TDC=60000** (%%) Set transmit interval to 60 seconds 1223 1223 1224 -AT+ RX2DR=5SetRX2DRto match the downlinkDRfrom server.see below1232 +(% style="background-color:#dcdcdc" %)**AT+CHS=868400000**(%%) Set transmit frequency to 868.4Mhz 1225 1225 1226 -AT+ DADDR=2611AF1SetDeviceAddressto2601 1A F1, thisID can be foundLoRaServerportal.1234 +(% style="background-color:#dcdcdc" %)**AT+RX2FQ=868400000** (%%) Set RX2Frequency to 868.4Mhz (according to the result from server) 1227 1227 1228 -AT ZtMCU1236 +(% style="background-color:#dcdcdc" %)**AT+RX2DR=5** (%%) Set RX2DR to match the downlink DR from server. see below 1229 1229 1230 - **Note:**1238 +(% style="background-color:#dcdcdc" %)**AT+DADDR=26** (%%) 01 1A F1 Set Device Address to 26 01 1A F1, this ID can be found in the LoRa Server portal. 1231 1231 1240 +(% style="background-color:#dcdcdc" %)**ATZ** (%%) Reset MCU 1241 + 1242 +(% style="color:red" %)**Note:** 1243 + 1232 1232 1. Make sure the device is set to ABP mode in the IoT Server. 1233 1233 1. Make sure the LG01/02 gateway RX frequency is exactly the same as AT+CHS setting. 1234 1234 1. Make sure SF / bandwidth setting in LG01/LG02 match the settings of AT+DR. refer [[this link>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/&file=LoRaWAN%201.0.3%20Regional%20Parameters.xlsx]] to see what DR means.
- 1654135840598-282.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +1.3 MB - Content
- 1654136105500-922.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +203.7 KB - Content