... ... @@ -1077,46 +1077,50 @@
1077 1077  
1078 1078  User can set the output power duration before each sampling.
1079 1079  
1080 -* **AT Command:**
1080 +* AT Command:
1081 1081  
1082 -**Example:**
1082 +Example:
1083 1083  
1084 -**AT+3V3T=1000**  ~/~/ 3V3 output power will open 1s before each sampling.
1084 +AT+3V3T=1000 ~/~/ 3V3 output power will open 1s before each sampling.
1085 1085  
1086 -**AT+5VT=1000**  ~/~/ +5V output power will open 1s before each sampling.
1086 +AT+5VT=1000 ~/~/ +5V output power will open 1s before each sampling.
1087 1087  
1088 1088  
1089 -* **LoRaWAN Downlink Command:**
1089 +* LoRaWAN Downlink Command:
1090 1090  
1091 -**07 01 aa bb**  Same as AT+5VT=(aa bb)
1091 +07 01 aa bb  Same as AT+5VT=(aa bb)
1092 1092  
1093 -**07 02 aa bb**  Same as AT+3V3T=(aa bb)
1093 +07 02 aa bb  Same as AT+3V3T=(aa bb)
1094 1094  
1095 1095  
1096 -== 3.6 Buttons ==
1097 1097  
1098 -(% border="1" style="background-color:#ffffcc; color:green; width:233px" %)
1099 -|=(% style="width: 89px;" %)**Button**|=(% style="width: 141px;" %)**Feature**
1100 -|(% style="width:89px" %)**RST**|(% style="width:141px" %)Reboot RS485-BL
1101 1101  
1102 -== 3.7 +3V3 Output ==
1098 +1.
1099 +11. Buttons
1103 1103  
1101 +|**Button**|**Feature**
1102 +|**RST**|Reboot RS485-BL
1103 +
1104 +1.
1105 +11. +3V3 Output
1106 +
1104 1104  RS485-BL has a Controllable +3V3 output, user can use this output to power external sensor.
1105 1105  
1106 1106  The +3V3 output will be valid for every sampling. RS485-BL will enable +3V3 output before all sampling and disable the +3V3 after all sampling. 
1107 1107  
1111 +
1108 1108  The +3V3 output time can be controlled by AT Command.
1109 1109  
1114 +**AT+3V3T=1000**
1110 1110  
1111 -(% style="color:#037691" %)**AT+3V3T=1000**
1112 -
1113 -
1114 1114  Means set +3v3 valid time to have 1000ms. So, the real +3v3 output will actually have 1000ms + sampling time for other sensors.
1115 1115  
1118 +
1116 1116  By default, the AT+3V3T=0. This is a special case, means the +3V3 output is always on at any time
1117 1117  
1118 1118  
1119 -== 3.8 +5V Output ==
1122 +1.
1123 +11. +5V Output
1120 1120  
1121 1121  RS485-BL has a Controllable +5V output, user can use this output to power external sensor.
1122 1122  
... ... @@ -1125,7 +1125,7 @@
1125 1125  
1126 1126  The 5V output time can be controlled by AT Command.
1127 1127  
1128 -(% style="color:#037691" %)**AT+5VT=1000**
1132 +**AT+5VT=1000**
1129 1129  
1130 1130  Means set 5V valid time to have 1000ms. So, the real 5V output will actually have 1000ms + sampling time for other sensors.
1131 1131  
... ... @@ -1134,12 +1134,15 @@
1134 1134  
1135 1135  
1136 1136  
1137 -== 3.9 LEDs ==
1138 1138  
1142 +1.
1143 +11. LEDs
1144 +
1139 1139  |**LEDs**|**Feature**
1140 1140  |**LED1**|Blink when device transmit a packet.
1141 1141  
1142 -== 3.10 Switch Jumper ==
1148 +1.
1149 +11. Switch Jumper
1143 1143  
1144 1144  |**Switch Jumper**|**Feature**
1145 1145  |**SW1**|(((
... ... @@ -1184,7 +1184,7 @@
1184 1184  
1185 1185  
1186 1186  
1187 -1.
1194 +1.
1188 1188  11. Common AT Command Sequence
1189 1189  111. Multi-channel ABP mode (Use with SX1301/LG308)
1190 1190  
... ... @@ -1203,8 +1203,8 @@
1203 1203  
1204 1204  ATZ
1205 1205  
1206 -1.
1207 -11.
1213 +1.
1214 +11.
1208 1208  111. Single-channel ABP mode (Use with LG01/LG02)
1209 1209  
1210 1210  AT+FDR   Reset Parameters to Factory Default, Keys Reserve
... ... @@ -1279,7 +1279,7 @@
1279 1279  [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image035.png]] [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image036.png]]
1280 1280  
1281 1281  
1282 -1.
1289 +1.
1283 1283  11. How to change the LoRa Frequency Bands/Region?
1284 1284  
1285 1285  User can follow the introduction for [[how to upgrade image>>path:#upgrade_image]]. When download the images, choose the required image file for download.
... ... @@ -1286,7 +1286,7 @@
1286 1286  
1287 1287  
1288 1288  
1289 -1.
1296 +1.
1290 1290  11. How many RS485-Slave can RS485-BL connects?
1291 1291  
1292 1292  The RS485-BL can support max 32 RS485 devices. Each uplink command of RS485-BL can support max 16 different RS485 command. So RS485-BL can support max 16 RS485 devices pre-program in the device for uplink. For other devices no pre-program, user can use the [[downlink message (type code 0xA8) to poll their info>>path:#downlink_A8]].
... ... @@ -1303,7 +1303,7 @@
1303 1303  
1304 1304  
1305 1305  
1306 -1.
1313 +1.
1307 1307  11. Why I can’t join TTN V3 in US915 /AU915 bands?
1308 1308  
1309 1309  It might about the channels mapping. Please see for detail.