... ... @@ -1077,50 +1077,47 @@
1077 1077  
1078 1078  User can set the output power duration before each sampling.
1079 1079  
1080 -* AT Command:
1080 +* **AT Command:**
1081 1081  
1082 -Example:
1082 +**Example:**
1083 1083  
1084 -AT+3V3T=1000 ~/~/ 3V3 output power will open 1s before each sampling.
1084 +**AT+3V3T=1000**  ~/~/ 3V3 output power will open 1s before each sampling.
1085 1085  
1086 -AT+5VT=1000 ~/~/ +5V output power will open 1s before each sampling.
1086 +**AT+5VT=1000**  ~/~/ +5V output power will open 1s before each sampling.
1087 1087  
1088 1088  
1089 -* LoRaWAN Downlink Command:
1089 +* **LoRaWAN Downlink Command:**
1090 1090  
1091 -07 01 aa bb  Same as AT+5VT=(aa bb)
1091 +**07 01 aa bb**  Same as AT+5VT=(aa bb)
1092 1092  
1093 -07 02 aa bb  Same as AT+3V3T=(aa bb)
1093 +**07 02 aa bb**  Same as AT+3V3T=(aa bb)
1094 1094  
1095 1095  
1096 +== 3.6 Buttons ==
1096 1096  
1098 +(% border="1" style="background-color:#ffffcc; color:green; width:233px" %)
1099 +|=(% style="width: 89px;" %)**Button**|=(% style="width: 141px;" %)**Feature**
1100 +|(% style="width:89px" %)**RST**|(% style="width:141px" %)Reboot RS485-BL
1097 1097  
1098 -1.
1099 -11. Buttons
1100 1100  
1101 -|**Button**|**Feature**
1102 -|**RST**|Reboot RS485-BL
1103 +== 3.7 +3V3 Output ==
1103 1103  
1104 -1.
1105 -11. +3V3 Output
1106 -
1107 1107  RS485-BL has a Controllable +3V3 output, user can use this output to power external sensor.
1108 1108  
1109 1109  The +3V3 output will be valid for every sampling. RS485-BL will enable +3V3 output before all sampling and disable the +3V3 after all sampling. 
1110 1110  
1111 -
1112 1112  The +3V3 output time can be controlled by AT Command.
1113 1113  
1114 -**AT+3V3T=1000**
1115 1115  
1116 -Means set +3v3 valid time to have 1000ms. So, the real +3v3 output will actually have 1000ms + sampling time for other sensors.
1112 +(% style="color:#037691" %)**AT+3V3T=1000**
1117 1117  
1118 1118  
1115 +Means set +3v3 valid time to have 1000ms. So, the real +3v3 output will actually have 1000ms + sampling time for other sensors.
1116 +
1119 1119  By default, the AT+3V3T=0. This is a special case, means the +3V3 output is always on at any time
1120 1120  
1121 1121  
1122 -1.
1123 -11. +5V Output
1120 +== 3.8 +5V Output ==
1124 1124  
1125 1125  RS485-BL has a Controllable +5V output, user can use this output to power external sensor.
1126 1126  
... ... @@ -1129,7 +1129,7 @@
1129 1129  
1130 1130  The 5V output time can be controlled by AT Command.
1131 1131  
1132 -**AT+5VT=1000**
1129 +(% style="color:#037691" %)**AT+5VT=1000**
1133 1133  
1134 1134  Means set 5V valid time to have 1000ms. So, the real 5V output will actually have 1000ms + sampling time for other sensors.
1135 1135  
... ... @@ -1138,15 +1138,12 @@
1138 1138  
1139 1139  
1140 1140  
1138 +== 3.9 LEDs ==
1141 1141  
1142 -1.
1143 -11. LEDs
1144 -
1145 1145  |**LEDs**|**Feature**
1146 1146  |**LED1**|Blink when device transmit a packet.
1147 1147  
1148 -1.
1149 -11. Switch Jumper
1143 +== 3.10 Switch Jumper ==
1150 1150  
1151 1151  |**Switch Jumper**|**Feature**
1152 1152  |**SW1**|(((
... ... @@ -1191,7 +1191,7 @@
1191 1191  
1192 1192  
1193 1193  
1194 -1.
1188 +1.
1195 1195  11. Common AT Command Sequence
1196 1196  111. Multi-channel ABP mode (Use with SX1301/LG308)
1197 1197  
... ... @@ -1210,8 +1210,8 @@
1210 1210  
1211 1211  ATZ
1212 1212  
1213 -1.
1214 -11.
1207 +1.
1208 +11.
1215 1215  111. Single-channel ABP mode (Use with LG01/LG02)
1216 1216  
1217 1217  AT+FDR   Reset Parameters to Factory Default, Keys Reserve
... ... @@ -1286,7 +1286,7 @@
1286 1286  [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image035.png]] [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image036.png]]
1287 1287  
1288 1288  
1289 -1.
1283 +1.
1290 1290  11. How to change the LoRa Frequency Bands/Region?
1291 1291  
1292 1292  User can follow the introduction for [[how to upgrade image>>path:#upgrade_image]]. When download the images, choose the required image file for download.
... ... @@ -1293,7 +1293,7 @@
1293 1293  
1294 1294  
1295 1295  
1296 -1.
1290 +1.
1297 1297  11. How many RS485-Slave can RS485-BL connects?
1298 1298  
1299 1299  The RS485-BL can support max 32 RS485 devices. Each uplink command of RS485-BL can support max 16 different RS485 command. So RS485-BL can support max 16 RS485 devices pre-program in the device for uplink. For other devices no pre-program, user can use the [[downlink message (type code 0xA8) to poll their info>>path:#downlink_A8]].
... ... @@ -1310,7 +1310,7 @@
1310 1310  
1311 1311  
1312 1312  
1313 -1.
1307 +1.
1314 1314  11. Why I can’t join TTN V3 in US915 /AU915 bands?
1315 1315  
1316 1316  It might about the channels mapping. Please see for detail.