Changes for page RS485-BL – Waterproof RS485 to LoRaWAN Converter
Last modified by Xiaoling on 2025/04/23 15:57
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 1 removed)
Details
- Page properties
-
- Content
-
... ... @@ -921,6 +921,7 @@ 921 921 922 922 * **AT+MBFUN=0**: Disable Modbus fast reading. 923 923 924 + 924 924 **Example:** 925 925 926 926 * AT+MBFUN=1 and AT+DATACUT1/AT+DATACUT2 are not configure (0,0,0). ... ... @@ -939,7 +939,7 @@ 939 939 940 940 941 941 942 -==== **RS485 command timeout**====943 +==== RS485 command timeout ==== 943 943 944 944 Some Modbus device has slow action to send replies. This command is used to configure the RS485-BL to use longer time to wait for their action. 945 945 ... ... @@ -946,123 +946,106 @@ 946 946 Default value: 0, range: 0 ~~ 5 seconds 947 947 948 948 949 -* **AT Command:**950 +* AT Command: 950 950 951 -(% class="box infomessage" %) 952 -((( 953 -**AT+CMDDLaa=hex(bb cc)** 954 -))) 952 +AT+CMDDLaa=hex(bb cc) 955 955 956 - **Example:**954 +Example: 957 957 958 958 **AT+CMDDL1=1000** to send the open time to 1000ms 959 959 960 960 961 -* **Downlink Payload:**959 +* Downlink Payload: 962 962 963 963 0x AA aa bb cc 964 964 965 965 Same as: AT+CMDDLaa=hex(bb cc) 966 966 967 - **Example:**965 + Example: 968 968 969 - **0xAA 01 03 E8**~-~->Same as **AT+CMDDL1=1000 ms**967 + 0xAA 01 03 E8 à Same as **AT+CMDDL1=1000 ms** 970 970 971 971 970 +==== [[Uplink>>path:#downlink_A8]] payload mode ==== 972 972 973 -==== **Uplink payload mode** ==== 974 - 975 975 Define to use one uplink or multiple uplinks for the sampling. 976 976 977 -The use of this command please see: [[Compose Uplink payload>> ||anchor="H3.3.4Composetheuplinkpayload"]]974 +The use of this command please see: [[Compose Uplink payload>>path:#DataUP]] 978 978 979 -* **AT Command:**976 +* AT Command: 980 980 981 -(% class="box infomessage" %) 982 -((( 983 -**AT+DATAUP=0** 984 -))) 978 +AT+DATAUP=0 985 985 986 -(% class="box infomessage" %) 987 -((( 988 -**AT+DATAUP=1** 989 -))) 980 +AT+DATAUP=1 990 990 991 991 992 -* **Downlink Payload:**983 +* Downlink Payload: 993 993 994 - **0xAD 00****~-~->**Same as AT+DATAUP=0985 +0xAD 00 à Same as AT+DATAUP=0 995 995 996 - **0xAD 01****~-~->**Same as AT+DATAUP=1987 +0xAD 01 à Same as AT+DATAUP=1 997 997 998 998 990 +==== Manually trigger an Uplink ==== 999 999 1000 -==== **Manually trigger an Uplink** ==== 1001 - 1002 1002 Ask device to send an uplink immediately. 1003 1003 1004 -* **Downlink Payload:**994 +* Downlink Payload: 1005 1005 1006 - **0x08 FF**, RS485-BL will immediately send an uplink.996 +0x08 FF, RS485-BL will immediately send an uplink. 1007 1007 1008 1008 999 +==== Clear RS485 Command ==== 1009 1009 1010 -==== **Clear RS485 Command** ==== 1011 - 1012 1012 The AT+COMMANDx and AT+DATACUTx settings are stored in special location, user can use below command to clear them. 1013 1013 1014 1014 1015 -* **AT Command:**1004 +* AT Command: 1016 1016 1017 - (% style="color:#037691" %)**AT+CMDEAR=mm,nn**(%%)mm: start position of erase ,nn: stop position of eraseEtc. AT+CMDEAR=1,10 means erase AT+COMMAND1/AT+DATACUT1 to AT+COMMAND10/AT+DATACUT101006 +**AT+CMDEAR=mm,nn** mm: start position of erase ,nn: stop position of erase 1018 1018 1008 +Etc. AT+CMDEAR=1,10 means erase AT+COMMAND1/AT+DATACUT1 to AT+COMMAND10/AT+DATACUT10 1009 + 1019 1019 Example screen shot after clear all RS485 commands. 1020 1020 1021 1021 1013 + 1022 1022 The uplink screen shot is: 1023 1023 1024 -[[image: 1654134704555-320.png]]1016 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image023.png]] 1025 1025 1026 1026 1027 -* **Downlink Payload:**1019 +* Downlink Payload: 1028 1028 1029 - **0x09 aa bb**same as AT+CMDEAR=aa,bb1021 +0x09 aa bb same as AT+CMDEAR=aa,bb 1030 1030 1031 1031 1024 +==== Set Serial Communication Parameters ==== 1032 1032 1033 -==== **Set Serial Communication Parameters** ==== 1034 - 1035 1035 Set the Rs485 serial communication parameters: 1036 1036 1037 -* **AT Command:**1028 +* AT Command: 1038 1038 1039 1039 Set Baud Rate: 1040 1040 1041 -(% class="box infomessage" %) 1042 -((( 1043 -**AT+BAUDR=9600** ~/~/ Options: (1200,2400,4800,14400,19200,115200) 1044 -))) 1032 +AT+BAUDR=9600 ~/~/ Options: (1200,2400,4800,14400,19200,115200) 1045 1045 1046 -Set UART Parity 1047 1047 1048 -(% class="box infomessage" %) 1049 -((( 1050 -**AT+PARITY=0** ~/~/ Option: 0: no parity, 1: odd parity, 2: even parity 1051 -))) 1035 +Set UART parity 1052 1052 1037 +AT+PARITY=0 ~/~/ Option: 0: no parity, 1: odd parity, 2: even parity 1038 + 1039 + 1053 1053 Set STOPBIT 1054 1054 1055 -(% class="box infomessage" %) 1056 -((( 1057 -**AT+STOPBIT=0** ~/~/ Option: 0 for 1bit; 1 for 1.5 bit ; 2 for 2 bits 1058 -))) 1042 +AT+STOPBIT=0 ~/~/ Option: 0 for 1bit; 1 for 1.5 bit ; 2 for 2 bits 1059 1059 1060 1060 1061 -* **Downlink Payload:**1045 +* Downlink Payload: 1062 1062 1063 - **A7 01 aa bb**: Same AT+BAUDR=hex(aa bb)*1001047 +A7 01 aa bb: Same AT+BAUDR=hex(aa bb)*100 1064 1064 1065 - **Example:**1049 +Example: 1066 1066 1067 1067 * A7 01 00 60 same as AT+BAUDR=9600 1068 1068 * A7 01 04 80 same as AT+BAUDR=115200 ... ... @@ -1072,9 +1072,8 @@ 1072 1072 A7 03 aa: Same as AT+STOPBIT=aa (aa value: 00 , 01 or 02) 1073 1073 1074 1074 1059 +==== Control output power duration ==== 1075 1075 1076 -==== **Control output power duration** ==== 1077 - 1078 1078 User can set the output power duration before each sampling. 1079 1079 1080 1080 * AT Command:
- 1654134704555-320.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -91.4 KB - Content