Last modified by Xiaoling on 2025/04/23 15:57

From version 33.10
edited by Xiaoling
on 2022/06/02 10:09
Change comment: There is no comment for this version
To version 35.4
edited by Xiaoling
on 2022/06/02 10:17
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1139,7 +1139,6 @@
1139 1139  |=**LEDs**|=(% style="width: 274px;" %)**Feature**
1140 1140  |**LED1**|(% style="width:274px" %)Blink when device transmit a packet.
1141 1141  
1142 -
1143 1143  == 3.10 Switch Jumper ==
1144 1144  
1145 1145  (% border="1" style="background-color:#ffffcc; color:green; width:515px" %)
... ... @@ -1165,50 +1165,61 @@
1165 1165  User can check this URL for some case studies: [[APP RS485 COMMUNICATE WITH SENSORS>>doc:Main.Application Note \: Communicate with Different Sensors ----- RS485-LN RS485-BL.WebHome]]
1166 1166  
1167 1167  
1167 += 5. Use AT Command =
1168 1168  
1169 +== 5.1 Access AT Command ==
1169 1169  
1170 -
1171 -1. Use AT Command
1172 -11. Access AT Command
1173 -
1174 1174  RS485-BL supports AT Command set. User can use a USB to TTL adapter plus the 3.5mm Program Cable to connect to RS485-BL to use AT command, as below.
1175 1175  
1176 -[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image027.png]]
1173 +[[image:1654135840598-282.png]]
1177 1177  
1178 1178  
1179 -In PC, User needs to set **serial tool**(such as [[putty>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to **9600** to access to access serial console of RS485-BL. The default password is 123456. Below is the output for reference:
1176 +In PC, User needs to set (% style="color:blue" %)**serial tool**(%%)(such as [[putty>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to (% style="color:green" %)**9600**(%%) to access to access serial console of RS485-BL. The default password is 123456. Below is the output for reference:
1180 1180  
1181 -[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image028.png]]
1178 +[[image:1654136105500-922.png]]
1182 1182  
1183 1183  
1181 +More detail AT Command manual can be found at [[AT Command Manual>>||anchor="3.5ConfigureRS485-BLviaATorDownlink"]]
1184 1184  
1185 -More detail AT Command manual can be found at [[AT Command Manual>>path:#AT_COMMAND]]
1186 1186  
1184 +== 5.2 Common AT Command Sequence ==
1187 1187  
1186 +=== 5.2.1 Multi-channel ABP mode (Use with SX1301/LG308) ===
1188 1188  
1189 -1.
1190 -11. Common AT Command Sequence
1191 -111. Multi-channel ABP mode (Use with SX1301/LG308)
1192 -
1193 1193  If device has not joined network yet:
1194 1194  
1195 -AT+FDR
1190 +(% class="box infomessage" %)
1191 +(((
1192 +**AT+FDR**
1193 +)))
1196 1196  
1197 -AT+NJM=0
1195 +(% class="box infomessage" %)
1196 +(((
1197 +**AT+NJM=0**
1198 +)))
1198 1198  
1199 -ATZ
1200 +(% class="box infomessage" %)
1201 +(((
1202 +**ATZ**
1203 +)))
1200 1200  
1201 1201  
1202 1202  If device already joined network:
1203 1203  
1204 -AT+NJM=0
1208 +(% class="box infomessage" %)
1209 +(((
1210 +**AT+NJM=0**
1211 +)))
1205 1205  
1206 -ATZ
1213 +(% class="box infomessage" %)
1214 +(((
1215 +**ATZ**
1216 +)))
1207 1207  
1208 -1.
1209 -11.
1210 -111. Single-channel ABP mode (Use with LG01/LG02)
1211 1211  
1219 +=== 5.5.2 Single-channel ABP mode (Use with LG01/LG02) ===
1220 +
1221 +
1212 1212  AT+FDR   Reset Parameters to Factory Default, Keys Reserve
1213 1213  
1214 1214  AT+NJM=0 Set to ABP mode
1654135840598-282.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +1.3 MB
Content
1654136105500-922.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +203.7 KB
Content