Last modified by Xiaoling on 2025/04/23 15:57

From version 33.1
edited by Xiaoling
on 2022/06/02 09:51
Change comment: Uploaded new attachment "1654134704555-320.png", version {1}
To version 33.2
edited by Xiaoling
on 2022/06/02 09:54
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1012,52 +1012,57 @@
1012 1012  The AT+COMMANDx and AT+DATACUTx settings are stored in special location, user can use below command to clear them.
1013 1013  
1014 1014  
1015 -* AT Command:
1015 +* **AT Command:**
1016 1016  
1017 -**AT+CMDEAR=mm,nn**   mm: start position of erase ,nn: stop position of erase
1017 +(% style="color:#037691" %)**AT+CMDEAR=mm,nn** (%%) mm: start position of erase ,nn: stop position of erase Etc. AT+CMDEAR=1,10 means erase AT+COMMAND1/AT+DATACUT1 to AT+COMMAND10/AT+DATACUT10
1018 1018  
1019 -Etc. AT+CMDEAR=1,10 means erase AT+COMMAND1/AT+DATACUT1 to AT+COMMAND10/AT+DATACUT10
1020 -
1021 1021  Example screen shot after clear all RS485 commands. 
1022 1022  
1023 1023  
1024 -
1025 1025  The uplink screen shot is:
1026 1026  
1027 -[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image023.png]]
1024 +[[image:1654134704555-320.png]]
1028 1028  
1029 1029  
1030 -* Downlink Payload:
1027 +* **Downlink Payload:**
1031 1031  
1032 -0x09 aa bb same as AT+CMDEAR=aa,bb
1029 +**0x09 aa bb** same as AT+CMDEAR=aa,bb
1033 1033  
1034 1034  
1035 -==== Set Serial Communication Parameters ====
1036 1036  
1033 +==== **Set Serial Communication Parameters** ====
1034 +
1037 1037  Set the Rs485 serial communication parameters:
1038 1038  
1039 -* AT Command:
1037 +* **AT Command:**
1040 1040  
1041 1041  Set Baud Rate:
1042 1042  
1043 -AT+BAUDR=9600    ~/~/ Options: (1200,2400,4800,14400,19200,115200)
1041 +(% class="box infomessage" %)
1042 +(((
1043 +**AT+BAUDR=9600**    ~/~/ Options: (1200,2400,4800,14400,19200,115200)
1044 +)))
1044 1044  
1046 +Set UART Parity
1045 1045  
1046 -Set UART parity
1048 +(% class="box infomessage" %)
1049 +(((
1050 +**AT+PARITY=0**    ~/~/ Option: 0: no parity, 1: odd parity, 2: even parity
1051 +)))
1047 1047  
1048 -AT+PARITY=0    ~/~/ Option: 0: no parity, 1: odd parity, 2: even parity
1049 -
1050 -
1051 1051  Set STOPBIT
1052 1052  
1053 -AT+STOPBIT=0    ~/~/ Option: 0 for 1bit; 1 for 1.5 bit ; 2 for 2 bits
1055 +(% class="box infomessage" %)
1056 +(((
1057 +**AT+STOPBIT=0**    ~/~/ Option: 0 for 1bit; 1 for 1.5 bit ; 2 for 2 bits
1058 +)))
1054 1054  
1055 1055  
1056 -* Downlink Payload:
1061 +* **Downlink Payload:**
1057 1057  
1058 -A7 01 aa bb: Same  AT+BAUDR=hex(aa bb)*100
1063 +**A7 01 aa bb**: Same  AT+BAUDR=hex(aa bb)*100
1059 1059  
1060 -Example:
1065 +**Example:**
1061 1061  
1062 1062  * A7 01 00 60   same as AT+BAUDR=9600
1063 1063  * A7 01 04 80  same as AT+BAUDR=115200
... ... @@ -1067,8 +1067,9 @@
1067 1067  A7 03 aa: Same as  AT+STOPBIT=aa  (aa value: 00 , 01 or 02)
1068 1068  
1069 1069  
1070 -==== Control output power duration ====
1071 1071  
1076 +==== **Control output power duration** ====
1077 +
1072 1072  User can set the output power duration before each sampling.
1073 1073  
1074 1074  * AT Command:
... ... @@ -1089,13 +1089,13 @@
1089 1089  
1090 1090  
1091 1091  
1092 -1.
1098 +1.
1093 1093  11. Buttons
1094 1094  
1095 1095  |**Button**|**Feature**
1096 1096  |**RST**|Reboot RS485-BL
1097 1097  
1098 -1.
1104 +1.
1099 1099  11. +3V3 Output
1100 1100  
1101 1101  RS485-BL has a Controllable +3V3 output, user can use this output to power external sensor.
... ... @@ -1113,7 +1113,7 @@
1113 1113  By default, the AT+3V3T=0. This is a special case, means the +3V3 output is always on at any time
1114 1114  
1115 1115  
1116 -1.
1122 +1.
1117 1117  11. +5V Output
1118 1118  
1119 1119  RS485-BL has a Controllable +5V output, user can use this output to power external sensor.
... ... @@ -1133,13 +1133,13 @@
1133 1133  
1134 1134  
1135 1135  
1136 -1.
1142 +1.
1137 1137  11. LEDs
1138 1138  
1139 1139  |**LEDs**|**Feature**
1140 1140  |**LED1**|Blink when device transmit a packet.
1141 1141  
1142 -1.
1148 +1.
1143 1143  11. Switch Jumper
1144 1144  
1145 1145  |**Switch Jumper**|**Feature**
... ... @@ -1185,7 +1185,7 @@
1185 1185  
1186 1186  
1187 1187  
1188 -1.
1194 +1.
1189 1189  11. Common AT Command Sequence
1190 1190  111. Multi-channel ABP mode (Use with SX1301/LG308)
1191 1191  
... ... @@ -1204,8 +1204,8 @@
1204 1204  
1205 1205  ATZ
1206 1206  
1207 -1.
1208 -11.
1213 +1.
1214 +11.
1209 1209  111. Single-channel ABP mode (Use with LG01/LG02)
1210 1210  
1211 1211  AT+FDR   Reset Parameters to Factory Default, Keys Reserve
... ... @@ -1280,7 +1280,7 @@
1280 1280  [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image035.png]] [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image036.png]]
1281 1281  
1282 1282  
1283 -1.
1289 +1.
1284 1284  11. How to change the LoRa Frequency Bands/Region?
1285 1285  
1286 1286  User can follow the introduction for [[how to upgrade image>>path:#upgrade_image]]. When download the images, choose the required image file for download.
... ... @@ -1287,7 +1287,7 @@
1287 1287  
1288 1288  
1289 1289  
1290 -1.
1296 +1.
1291 1291  11. How many RS485-Slave can RS485-BL connects?
1292 1292  
1293 1293  The RS485-BL can support max 32 RS485 devices. Each uplink command of RS485-BL can support max 16 different RS485 command. So RS485-BL can support max 16 RS485 devices pre-program in the device for uplink. For other devices no pre-program, user can use the [[downlink message (type code 0xA8) to poll their info>>path:#downlink_A8]].
... ... @@ -1304,7 +1304,7 @@
1304 1304  
1305 1305  
1306 1306  
1307 -1.
1313 +1.
1308 1308  11. Why I can’t join TTN V3 in US915 /AU915 bands?
1309 1309  
1310 1310  It might about the channels mapping. Please see for detail.