Changes for page RS485-BL – Waterproof RS485 to LoRaWAN Converter
Last modified by Xiaoling on 2025/04/23 15:57
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1001,62 +1001,68 @@ 1001 1001 1002 1002 Ask device to send an uplink immediately. 1003 1003 1004 -* Downlink Payload: 1004 +* **Downlink Payload:** 1005 1005 1006 -0x08 FF, RS485-BL will immediately send an uplink. 1006 +**0x08 FF**, RS485-BL will immediately send an uplink. 1007 1007 1008 1008 1009 -==== Clear RS485 Command ==== 1010 1010 1010 +==== **Clear RS485 Command** ==== 1011 + 1011 1011 The AT+COMMANDx and AT+DATACUTx settings are stored in special location, user can use below command to clear them. 1012 1012 1013 1013 1014 -* AT Command: 1015 +* **AT Command:** 1015 1015 1016 -**AT+CMDEAR=mm,nn** 1017 +(% style="color:#037691" %)**AT+CMDEAR=mm,nn** (%%) mm: start position of erase ,nn: stop position of erase Etc. AT+CMDEAR=1,10 means erase AT+COMMAND1/AT+DATACUT1 to AT+COMMAND10/AT+DATACUT10 1017 1017 1018 -Etc. AT+CMDEAR=1,10 means erase AT+COMMAND1/AT+DATACUT1 to AT+COMMAND10/AT+DATACUT10 1019 - 1020 1020 Example screen shot after clear all RS485 commands. 1021 1021 1022 1022 1023 - 1024 1024 The uplink screen shot is: 1025 1025 1026 -[[image: file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image023.png]]1024 +[[image:1654134704555-320.png]] 1027 1027 1028 1028 1029 -* Downlink Payload: 1027 +* **Downlink Payload:** 1030 1030 1031 -0x09 aa bb same as AT+CMDEAR=aa,bb 1029 +**0x09 aa bb** same as AT+CMDEAR=aa,bb 1032 1032 1033 1033 1034 -==== Set Serial Communication Parameters ==== 1035 1035 1033 +==== **Set Serial Communication Parameters** ==== 1034 + 1036 1036 Set the Rs485 serial communication parameters: 1037 1037 1038 -* AT Command: 1037 +* **AT Command:** 1039 1039 1040 1040 Set Baud Rate: 1041 1041 1042 -AT+BAUDR=9600 ~/~/ Options: (1200,2400,4800,14400,19200,115200) 1041 +(% class="box infomessage" %) 1042 +((( 1043 +**AT+BAUDR=9600** ~/~/ Options: (1200,2400,4800,14400,19200,115200) 1044 +))) 1043 1043 1046 +Set UART Parity 1044 1044 1045 -Set UART parity 1048 +(% class="box infomessage" %) 1049 +((( 1050 +**AT+PARITY=0** ~/~/ Option: 0: no parity, 1: odd parity, 2: even parity 1051 +))) 1046 1046 1047 -AT+PARITY=0 ~/~/ Option: 0: no parity, 1: odd parity, 2: even parity 1048 - 1049 - 1050 1050 Set STOPBIT 1051 1051 1052 -AT+STOPBIT=0 ~/~/ Option: 0 for 1bit; 1 for 1.5 bit ; 2 for 2 bits 1055 +(% class="box infomessage" %) 1056 +((( 1057 +**AT+STOPBIT=0** ~/~/ Option: 0 for 1bit; 1 for 1.5 bit ; 2 for 2 bits 1058 +))) 1053 1053 1054 1054 1055 -* Downlink Payload: 1061 +* **Downlink Payload:** 1056 1056 1057 -A7 01 aa bb: Same AT+BAUDR=hex(aa bb)*100 1063 +**A7 01 aa bb**: Same AT+BAUDR=hex(aa bb)*100 1058 1058 1059 -Example: 1065 +**Example:** 1060 1060 1061 1061 * A7 01 00 60 same as AT+BAUDR=9600 1062 1062 * A7 01 04 80 same as AT+BAUDR=115200 ... ... @@ -1066,54 +1066,51 @@ 1066 1066 A7 03 aa: Same as AT+STOPBIT=aa (aa value: 00 , 01 or 02) 1067 1067 1068 1068 1069 -==== Control output power duration ==== 1070 1070 1076 +==== **Control output power duration** ==== 1077 + 1071 1071 User can set the output power duration before each sampling. 1072 1072 1073 -* AT Command: 1080 +* **AT Command:** 1074 1074 1075 -Example: 1082 +**Example:** 1076 1076 1077 -AT+3V3T=1000 ~/~/ 3V3 output power will open 1s before each sampling. 1084 +**AT+3V3T=1000** ~/~/ 3V3 output power will open 1s before each sampling. 1078 1078 1079 -AT+5VT=1000 ~/~/ +5V output power will open 1s before each sampling. 1086 +**AT+5VT=1000** ~/~/ +5V output power will open 1s before each sampling. 1080 1080 1081 1081 1082 -* LoRaWAN Downlink Command: 1089 +* **LoRaWAN Downlink Command:** 1083 1083 1084 -07 01 aa bb Same as AT+5VT=(aa bb) 1091 +**07 01 aa bb** Same as AT+5VT=(aa bb) 1085 1085 1086 -07 02 aa bb Same as AT+3V3T=(aa bb) 1093 +**07 02 aa bb** Same as AT+3V3T=(aa bb) 1087 1087 1088 1088 1096 +== 3.6 Buttons == 1089 1089 1098 +(% border="1" style="background-color:#ffffcc; color:green; width:233px" %) 1099 +|=(% style="width: 89px;" %)**Button**|=(% style="width: 141px;" %)**Feature** 1100 +|(% style="width:89px" %)**RST**|(% style="width:141px" %)Reboot RS485-BL 1090 1090 1091 -1. 1092 -11. Buttons 1102 +== 3.7 +3V3 Output == 1093 1093 1094 -|**Button**|**Feature** 1095 -|**RST**|Reboot RS485-BL 1096 - 1097 -1. 1098 -11. +3V3 Output 1099 - 1100 1100 RS485-BL has a Controllable +3V3 output, user can use this output to power external sensor. 1101 1101 1102 1102 The +3V3 output will be valid for every sampling. RS485-BL will enable +3V3 output before all sampling and disable the +3V3 after all sampling. 1103 1103 1104 - 1105 1105 The +3V3 output time can be controlled by AT Command. 1106 1106 1107 -**AT+3V3T=1000** 1108 1108 1109 - Meansset+3v3 valid timetohave 1000ms. So, thereal+3v3output will actually have1000ms + sampling time for other sensors.1111 +(% style="color:#037691" %)**AT+3V3T=1000** 1110 1110 1111 1111 1114 +Means set +3v3 valid time to have 1000ms. So, the real +3v3 output will actually have 1000ms + sampling time for other sensors. 1115 + 1112 1112 By default, the AT+3V3T=0. This is a special case, means the +3V3 output is always on at any time 1113 1113 1114 1114 1115 -1. 1116 -11. +5V Output 1119 +== 3.8 +5V Output == 1117 1117 1118 1118 RS485-BL has a Controllable +5V output, user can use this output to power external sensor. 1119 1119 ... ... @@ -1122,7 +1122,7 @@ 1122 1122 1123 1123 The 5V output time can be controlled by AT Command. 1124 1124 1125 -**AT+5VT=1000** 1128 +(% style="color:#037691" %)**AT+5VT=1000** 1126 1126 1127 1127 Means set 5V valid time to have 1000ms. So, the real 5V output will actually have 1000ms + sampling time for other sensors. 1128 1128 ... ... @@ -1131,15 +1131,12 @@ 1131 1131 1132 1132 1133 1133 1137 +== 3.9 LEDs == 1134 1134 1135 -1. 1136 -11. LEDs 1137 - 1138 1138 |**LEDs**|**Feature** 1139 1139 |**LED1**|Blink when device transmit a packet. 1140 1140 1141 -1. 1142 -11. Switch Jumper 1142 +== 3.10 Switch Jumper == 1143 1143 1144 1144 |**Switch Jumper**|**Feature** 1145 1145 |**SW1**|(((
- 1654134704555-320.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +91.4 KB - Content