Changes for page RS485-BL – Waterproof RS485 to LoRaWAN Converter
Last modified by Xiaoling on 2025/04/23 15:57
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -921,7 +921,6 @@ 921 921 922 922 * **AT+MBFUN=0**: Disable Modbus fast reading. 923 923 924 - 925 925 **Example:** 926 926 927 927 * AT+MBFUN=1 and AT+DATACUT1/AT+DATACUT2 are not configure (0,0,0). ... ... @@ -940,7 +940,7 @@ 940 940 941 941 942 942 943 -==== RS485 command timeout ==== 942 +==== **RS485 command timeout** ==== 944 944 945 945 Some Modbus device has slow action to send replies. This command is used to configure the RS485-BL to use longer time to wait for their action. 946 946 ... ... @@ -947,106 +947,123 @@ 947 947 Default value: 0, range: 0 ~~ 5 seconds 948 948 949 949 950 -* AT Command: 949 +* **AT Command:** 951 951 952 -AT+CMDDLaa=hex(bb cc) 951 +(% class="box infomessage" %) 952 +((( 953 +**AT+CMDDLaa=hex(bb cc)** 954 +))) 953 953 954 -Example: 956 +**Example:** 955 955 956 956 **AT+CMDDL1=1000** to send the open time to 1000ms 957 957 958 958 959 -* Downlink Payload: 961 +* **Downlink Payload:** 960 960 961 961 0x AA aa bb cc 962 962 963 963 Same as: AT+CMDDLaa=hex(bb cc) 964 964 965 - Example: 967 + **Example:** 966 966 967 - 0xAA 01 03 E8 àSame as **AT+CMDDL1=1000 ms**969 + **0xAA 01 03 E8** ~-~-> Same as **AT+CMDDL1=1000 ms** 968 968 969 969 970 -==== [[Uplink>>path:#downlink_A8]] payload mode ==== 971 971 973 +==== **Uplink payload mode** ==== 974 + 972 972 Define to use one uplink or multiple uplinks for the sampling. 973 973 974 -The use of this command please see: [[Compose Uplink payload>> path:#DataUP]]977 +The use of this command please see: [[Compose Uplink payload>>||anchor="H3.3.4Composetheuplinkpayload"]] 975 975 976 -* AT Command: 979 +* **AT Command:** 977 977 978 -AT+DATAUP=0 981 +(% class="box infomessage" %) 982 +((( 983 +**AT+DATAUP=0** 984 +))) 979 979 980 -AT+DATAUP=1 986 +(% class="box infomessage" %) 987 +((( 988 +**AT+DATAUP=1** 989 +))) 981 981 982 982 983 -* Downlink Payload: 992 +* **Downlink Payload:** 984 984 985 -0xAD 00 àSame as AT+DATAUP=0994 +**0xAD 00** **~-~->** Same as AT+DATAUP=0 986 986 987 -0xAD 01 àSame as AT+DATAUP=1996 +**0xAD 01** **~-~->** Same as AT+DATAUP=1 988 988 989 989 990 -==== Manually trigger an Uplink ==== 991 991 1000 +==== **Manually trigger an Uplink** ==== 1001 + 992 992 Ask device to send an uplink immediately. 993 993 994 -* Downlink Payload: 1004 +* **Downlink Payload:** 995 995 996 -0x08 FF, RS485-BL will immediately send an uplink. 1006 +**0x08 FF**, RS485-BL will immediately send an uplink. 997 997 998 998 999 -==== Clear RS485 Command ==== 1000 1000 1010 +==== **Clear RS485 Command** ==== 1011 + 1001 1001 The AT+COMMANDx and AT+DATACUTx settings are stored in special location, user can use below command to clear them. 1002 1002 1003 1003 1004 -* AT Command: 1015 +* **AT Command:** 1005 1005 1006 -**AT+CMDEAR=mm,nn** 1017 +(% style="color:#037691" %)**AT+CMDEAR=mm,nn** (%%) mm: start position of erase ,nn: stop position of erase Etc. AT+CMDEAR=1,10 means erase AT+COMMAND1/AT+DATACUT1 to AT+COMMAND10/AT+DATACUT10 1007 1007 1008 -Etc. AT+CMDEAR=1,10 means erase AT+COMMAND1/AT+DATACUT1 to AT+COMMAND10/AT+DATACUT10 1009 - 1010 1010 Example screen shot after clear all RS485 commands. 1011 1011 1012 1012 1013 - 1014 1014 The uplink screen shot is: 1015 1015 1016 -[[image: file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image023.png]]1024 +[[image:1654134704555-320.png]] 1017 1017 1018 1018 1019 -* Downlink Payload: 1027 +* **Downlink Payload:** 1020 1020 1021 -0x09 aa bb same as AT+CMDEAR=aa,bb 1029 +**0x09 aa bb** same as AT+CMDEAR=aa,bb 1022 1022 1023 1023 1024 -==== Set Serial Communication Parameters ==== 1025 1025 1033 +==== **Set Serial Communication Parameters** ==== 1034 + 1026 1026 Set the Rs485 serial communication parameters: 1027 1027 1028 -* AT Command: 1037 +* **AT Command:** 1029 1029 1030 1030 Set Baud Rate: 1031 1031 1032 -AT+BAUDR=9600 ~/~/ Options: (1200,2400,4800,14400,19200,115200) 1041 +(% class="box infomessage" %) 1042 +((( 1043 +**AT+BAUDR=9600** ~/~/ Options: (1200,2400,4800,14400,19200,115200) 1044 +))) 1033 1033 1046 +Set UART Parity 1034 1034 1035 -Set UART parity 1048 +(% class="box infomessage" %) 1049 +((( 1050 +**AT+PARITY=0** ~/~/ Option: 0: no parity, 1: odd parity, 2: even parity 1051 +))) 1036 1036 1037 -AT+PARITY=0 ~/~/ Option: 0: no parity, 1: odd parity, 2: even parity 1038 - 1039 - 1040 1040 Set STOPBIT 1041 1041 1042 -AT+STOPBIT=0 ~/~/ Option: 0 for 1bit; 1 for 1.5 bit ; 2 for 2 bits 1055 +(% class="box infomessage" %) 1056 +((( 1057 +**AT+STOPBIT=0** ~/~/ Option: 0 for 1bit; 1 for 1.5 bit ; 2 for 2 bits 1058 +))) 1043 1043 1044 1044 1045 -* Downlink Payload: 1061 +* **Downlink Payload:** 1046 1046 1047 -A7 01 aa bb: Same AT+BAUDR=hex(aa bb)*100 1063 +**A7 01 aa bb**: Same AT+BAUDR=hex(aa bb)*100 1048 1048 1049 -Example: 1065 +**Example:** 1050 1050 1051 1051 * A7 01 00 60 same as AT+BAUDR=9600 1052 1052 * A7 01 04 80 same as AT+BAUDR=115200 ... ... @@ -1056,54 +1056,51 @@ 1056 1056 A7 03 aa: Same as AT+STOPBIT=aa (aa value: 00 , 01 or 02) 1057 1057 1058 1058 1059 -==== Control output power duration ==== 1060 1060 1076 +==== **Control output power duration** ==== 1077 + 1061 1061 User can set the output power duration before each sampling. 1062 1062 1063 -* AT Command: 1080 +* **AT Command:** 1064 1064 1065 -Example: 1082 +**Example:** 1066 1066 1067 -AT+3V3T=1000 ~/~/ 3V3 output power will open 1s before each sampling. 1084 +**AT+3V3T=1000** ~/~/ 3V3 output power will open 1s before each sampling. 1068 1068 1069 -AT+5VT=1000 ~/~/ +5V output power will open 1s before each sampling. 1086 +**AT+5VT=1000** ~/~/ +5V output power will open 1s before each sampling. 1070 1070 1071 1071 1072 -* LoRaWAN Downlink Command: 1089 +* **LoRaWAN Downlink Command:** 1073 1073 1074 -07 01 aa bb Same as AT+5VT=(aa bb) 1091 +**07 01 aa bb** Same as AT+5VT=(aa bb) 1075 1075 1076 -07 02 aa bb Same as AT+3V3T=(aa bb) 1093 +**07 02 aa bb** Same as AT+3V3T=(aa bb) 1077 1077 1078 1078 1096 +== 3.6 Buttons == 1079 1079 1098 +(% border="1" style="background-color:#ffffcc; color:green; width:233px" %) 1099 +|=(% style="width: 89px;" %)**Button**|=(% style="width: 141px;" %)**Feature** 1100 +|(% style="width:89px" %)**RST**|(% style="width:141px" %)Reboot RS485-BL 1080 1080 1081 -1. 1082 -11. Buttons 1102 +== 3.7 +3V3 Output == 1083 1083 1084 -|**Button**|**Feature** 1085 -|**RST**|Reboot RS485-BL 1086 - 1087 -1. 1088 -11. +3V3 Output 1089 - 1090 1090 RS485-BL has a Controllable +3V3 output, user can use this output to power external sensor. 1091 1091 1092 1092 The +3V3 output will be valid for every sampling. RS485-BL will enable +3V3 output before all sampling and disable the +3V3 after all sampling. 1093 1093 1094 - 1095 1095 The +3V3 output time can be controlled by AT Command. 1096 1096 1097 -**AT+3V3T=1000** 1098 1098 1099 - Meansset+3v3 valid timetohave 1000ms. So, thereal+3v3output will actually have1000ms + sampling time for other sensors.1111 +(% style="color:#037691" %)**AT+3V3T=1000** 1100 1100 1101 1101 1114 +Means set +3v3 valid time to have 1000ms. So, the real +3v3 output will actually have 1000ms + sampling time for other sensors. 1115 + 1102 1102 By default, the AT+3V3T=0. This is a special case, means the +3V3 output is always on at any time 1103 1103 1104 1104 1105 -1. 1106 -11. +5V Output 1119 +== 3.8 +5V Output == 1107 1107 1108 1108 RS485-BL has a Controllable +5V output, user can use this output to power external sensor. 1109 1109 ... ... @@ -1112,7 +1112,7 @@ 1112 1112 1113 1113 The 5V output time can be controlled by AT Command. 1114 1114 1115 -**AT+5VT=1000** 1128 +(% style="color:#037691" %)**AT+5VT=1000** 1116 1116 1117 1117 Means set 5V valid time to have 1000ms. So, the real 5V output will actually have 1000ms + sampling time for other sensors. 1118 1118 ... ... @@ -1121,15 +1121,12 @@ 1121 1121 1122 1122 1123 1123 1137 +== 3.9 LEDs == 1124 1124 1125 -1. 1126 -11. LEDs 1127 - 1128 1128 |**LEDs**|**Feature** 1129 1129 |**LED1**|Blink when device transmit a packet. 1130 1130 1131 -1. 1132 -11. Switch Jumper 1142 +== 3.10 Switch Jumper == 1133 1133 1134 1134 |**Switch Jumper**|**Feature** 1135 1135 |**SW1**|((( ... ... @@ -1174,7 +1174,7 @@ 1174 1174 1175 1175 1176 1176 1177 -1. 1187 +1. 1178 1178 11. Common AT Command Sequence 1179 1179 111. Multi-channel ABP mode (Use with SX1301/LG308) 1180 1180 ... ... @@ -1193,8 +1193,8 @@ 1193 1193 1194 1194 ATZ 1195 1195 1196 -1. 1197 -11. 1206 +1. 1207 +11. 1198 1198 111. Single-channel ABP mode (Use with LG01/LG02) 1199 1199 1200 1200 AT+FDR Reset Parameters to Factory Default, Keys Reserve ... ... @@ -1269,7 +1269,7 @@ 1269 1269 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image035.png]] [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image036.png]] 1270 1270 1271 1271 1272 -1. 1282 +1. 1273 1273 11. How to change the LoRa Frequency Bands/Region? 1274 1274 1275 1275 User can follow the introduction for [[how to upgrade image>>path:#upgrade_image]]. When download the images, choose the required image file for download. ... ... @@ -1276,7 +1276,7 @@ 1276 1276 1277 1277 1278 1278 1279 -1. 1289 +1. 1280 1280 11. How many RS485-Slave can RS485-BL connects? 1281 1281 1282 1282 The RS485-BL can support max 32 RS485 devices. Each uplink command of RS485-BL can support max 16 different RS485 command. So RS485-BL can support max 16 RS485 devices pre-program in the device for uplink. For other devices no pre-program, user can use the [[downlink message (type code 0xA8) to poll their info>>path:#downlink_A8]]. ... ... @@ -1293,7 +1293,7 @@ 1293 1293 1294 1294 1295 1295 1296 -1. 1306 +1. 1297 1297 11. Why I can’t join TTN V3 in US915 /AU915 bands? 1298 1298 1299 1299 It might about the channels mapping. Please see for detail.
- 1654134704555-320.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +91.4 KB - Content