Changes for page RS485-BL – Waterproof RS485 to LoRaWAN Converter
Last modified by Xiaoling on 2025/04/23 15:57
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -921,7 +921,6 @@ 921 921 922 922 * **AT+MBFUN=0**: Disable Modbus fast reading. 923 923 924 - 925 925 **Example:** 926 926 927 927 * AT+MBFUN=1 and AT+DATACUT1/AT+DATACUT2 are not configure (0,0,0). ... ... @@ -940,7 +940,7 @@ 940 940 941 941 942 942 943 -==== RS485 command timeout ==== 942 +==== **RS485 command timeout** ==== 944 944 945 945 Some Modbus device has slow action to send replies. This command is used to configure the RS485-BL to use longer time to wait for their action. 946 946 ... ... @@ -947,106 +947,123 @@ 947 947 Default value: 0, range: 0 ~~ 5 seconds 948 948 949 949 950 -* AT Command: 949 +* **AT Command:** 951 951 952 -AT+CMDDLaa=hex(bb cc) 951 +(% class="box infomessage" %) 952 +((( 953 +**AT+CMDDLaa=hex(bb cc)** 954 +))) 953 953 954 -Example: 956 +**Example:** 955 955 956 956 **AT+CMDDL1=1000** to send the open time to 1000ms 957 957 958 958 959 -* Downlink Payload: 961 +* **Downlink Payload:** 960 960 961 961 0x AA aa bb cc 962 962 963 963 Same as: AT+CMDDLaa=hex(bb cc) 964 964 965 - Example: 967 + **Example:** 966 966 967 - 0xAA 01 03 E8 àSame as **AT+CMDDL1=1000 ms**969 + **0xAA 01 03 E8** ~-~-> Same as **AT+CMDDL1=1000 ms** 968 968 969 969 970 -==== [[Uplink>>path:#downlink_A8]] payload mode ==== 971 971 973 +==== **Uplink payload mode** ==== 974 + 972 972 Define to use one uplink or multiple uplinks for the sampling. 973 973 974 -The use of this command please see: [[Compose Uplink payload>> path:#DataUP]]977 +The use of this command please see: [[Compose Uplink payload>>||anchor="H3.3.4Composetheuplinkpayload"]] 975 975 976 -* AT Command: 979 +* **AT Command:** 977 977 978 -AT+DATAUP=0 981 +(% class="box infomessage" %) 982 +((( 983 +**AT+DATAUP=0** 984 +))) 979 979 980 -AT+DATAUP=1 986 +(% class="box infomessage" %) 987 +((( 988 +**AT+DATAUP=1** 989 +))) 981 981 982 982 983 -* Downlink Payload: 992 +* **Downlink Payload:** 984 984 985 -0xAD 00 àSame as AT+DATAUP=0994 +**0xAD 00** **~-~->** Same as AT+DATAUP=0 986 986 987 -0xAD 01 àSame as AT+DATAUP=1996 +**0xAD 01** **~-~->** Same as AT+DATAUP=1 988 988 989 989 990 -==== Manually trigger an Uplink ==== 991 991 1000 +==== **Manually trigger an Uplink** ==== 1001 + 992 992 Ask device to send an uplink immediately. 993 993 994 -* Downlink Payload: 1004 +* **Downlink Payload:** 995 995 996 -0x08 FF, RS485-BL will immediately send an uplink. 1006 +**0x08 FF**, RS485-BL will immediately send an uplink. 997 997 998 998 999 -==== Clear RS485 Command ==== 1000 1000 1010 +==== **Clear RS485 Command** ==== 1011 + 1001 1001 The AT+COMMANDx and AT+DATACUTx settings are stored in special location, user can use below command to clear them. 1002 1002 1003 1003 1004 -* AT Command: 1015 +* **AT Command:** 1005 1005 1006 -**AT+CMDEAR=mm,nn** 1017 +(% style="color:#037691" %)**AT+CMDEAR=mm,nn** (%%) mm: start position of erase ,nn: stop position of erase Etc. AT+CMDEAR=1,10 means erase AT+COMMAND1/AT+DATACUT1 to AT+COMMAND10/AT+DATACUT10 1007 1007 1008 -Etc. AT+CMDEAR=1,10 means erase AT+COMMAND1/AT+DATACUT1 to AT+COMMAND10/AT+DATACUT10 1009 - 1010 1010 Example screen shot after clear all RS485 commands. 1011 1011 1012 1012 1013 - 1014 1014 The uplink screen shot is: 1015 1015 1016 -[[image: file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image023.png]]1024 +[[image:1654134704555-320.png]] 1017 1017 1018 1018 1019 -* Downlink Payload: 1027 +* **Downlink Payload:** 1020 1020 1021 -0x09 aa bb same as AT+CMDEAR=aa,bb 1029 +**0x09 aa bb** same as AT+CMDEAR=aa,bb 1022 1022 1023 1023 1024 -==== Set Serial Communication Parameters ==== 1025 1025 1033 +==== **Set Serial Communication Parameters** ==== 1034 + 1026 1026 Set the Rs485 serial communication parameters: 1027 1027 1028 -* AT Command: 1037 +* **AT Command:** 1029 1029 1030 1030 Set Baud Rate: 1031 1031 1032 -AT+BAUDR=9600 ~/~/ Options: (1200,2400,4800,14400,19200,115200) 1041 +(% class="box infomessage" %) 1042 +((( 1043 +**AT+BAUDR=9600** ~/~/ Options: (1200,2400,4800,14400,19200,115200) 1044 +))) 1033 1033 1046 +Set UART Parity 1034 1034 1035 -Set UART parity 1048 +(% class="box infomessage" %) 1049 +((( 1050 +**AT+PARITY=0** ~/~/ Option: 0: no parity, 1: odd parity, 2: even parity 1051 +))) 1036 1036 1037 -AT+PARITY=0 ~/~/ Option: 0: no parity, 1: odd parity, 2: even parity 1038 - 1039 - 1040 1040 Set STOPBIT 1041 1041 1042 -AT+STOPBIT=0 ~/~/ Option: 0 for 1bit; 1 for 1.5 bit ; 2 for 2 bits 1055 +(% class="box infomessage" %) 1056 +((( 1057 +**AT+STOPBIT=0** ~/~/ Option: 0 for 1bit; 1 for 1.5 bit ; 2 for 2 bits 1058 +))) 1043 1043 1044 1044 1045 -* Downlink Payload: 1061 +* **Downlink Payload:** 1046 1046 1047 -A7 01 aa bb: Same AT+BAUDR=hex(aa bb)*100 1063 +**A7 01 aa bb**: Same AT+BAUDR=hex(aa bb)*100 1048 1048 1049 -Example: 1065 +**Example:** 1050 1050 1051 1051 * A7 01 00 60 same as AT+BAUDR=9600 1052 1052 * A7 01 04 80 same as AT+BAUDR=115200 ... ... @@ -1056,24 +1056,25 @@ 1056 1056 A7 03 aa: Same as AT+STOPBIT=aa (aa value: 00 , 01 or 02) 1057 1057 1058 1058 1059 -==== Control output power duration ==== 1060 1060 1076 +==== **Control output power duration** ==== 1077 + 1061 1061 User can set the output power duration before each sampling. 1062 1062 1063 -* AT Command: 1080 +* **AT Command:** 1064 1064 1065 -Example: 1082 +**Example:** 1066 1066 1067 -AT+3V3T=1000 ~/~/ 3V3 output power will open 1s before each sampling. 1084 +**AT+3V3T=1000** ~/~/ 3V3 output power will open 1s before each sampling. 1068 1068 1069 -AT+5VT=1000 ~/~/ +5V output power will open 1s before each sampling. 1086 +**AT+5VT=1000** ~/~/ +5V output power will open 1s before each sampling. 1070 1070 1071 1071 1072 -* LoRaWAN Downlink Command: 1089 +* **LoRaWAN Downlink Command:** 1073 1073 1074 -07 01 aa bb Same as AT+5VT=(aa bb) 1091 +**07 01 aa bb** Same as AT+5VT=(aa bb) 1075 1075 1076 -07 02 aa bb Same as AT+3V3T=(aa bb) 1093 +**07 02 aa bb** Same as AT+3V3T=(aa bb) 1077 1077 1078 1078 1079 1079
- 1654134704555-320.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +91.4 KB - Content