Last modified by Xiaoling on 2025/04/23 15:57

From version 32.10
edited by Xiaoling
on 2022/06/02 09:47
Change comment: There is no comment for this version
To version 32.5
edited by Xiaoling
on 2022/06/02 09:41
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -921,6 +921,7 @@
921 921  
922 922  * **AT+MBFUN=0**: Disable Modbus fast reading.
923 923  
924 +
924 924  **Example:**
925 925  
926 926  * AT+MBFUN=1 and AT+DATACUT1/AT+DATACUT2 are not configure (0,0,0).
... ... @@ -969,46 +969,37 @@
969 969   **0xAA 01 03 E8**  ~-~-> Same as **AT+CMDDL1=1000 ms**
970 970  
971 971  
973 +==== [[Uplink>>path:#downlink_A8]] payload mode ====
972 972  
973 -==== **Uplink payload mode** ====
974 -
975 975  Define to use one uplink or multiple uplinks for the sampling.
976 976  
977 -The use of this command please see: [[Compose Uplink payload>>||anchor="H3.3.4Composetheuplinkpayload"]]
977 +The use of this command please see: [[Compose Uplink payload>>path:#DataUP]]
978 978  
979 -* **AT Command:**
979 +* AT Command:
980 980  
981 -(% class="box infomessage" %)
982 -(((
983 -**AT+DATAUP=0**
984 -)))
981 +AT+DATAUP=0
985 985  
986 -(% class="box infomessage" %)
987 -(((
988 -**AT+DATAUP=1**
989 -)))
983 +AT+DATAUP=1
990 990  
991 991  
992 -* **Downlink Payload:**
986 +* Downlink Payload:
993 993  
994 -**0xAD 00**  **~-~->** Same as AT+DATAUP=0
988 +0xAD 00   à Same as AT+DATAUP=0
995 995  
996 -**0xAD 01**  **~-~->** Same as AT+DATAUP=1
990 +0xAD 01   à Same as AT+DATAUP=1
997 997  
998 998  
993 +==== Manually trigger an Uplink ====
999 999  
1000 -==== **Manually trigger an Uplink** ====
1001 -
1002 1002  Ask device to send an uplink immediately.
1003 1003  
1004 -* **Downlink Payload:**
997 +* Downlink Payload:
1005 1005  
1006 -**0x08 FF**, RS485-BL will immediately send an uplink.
999 +0x08 FF, RS485-BL will immediately send an uplink.
1007 1007  
1008 1008  
1002 +==== Clear RS485 Command ====
1009 1009  
1010 -==== **Clear RS485 Command** ====
1011 -
1012 1012  The AT+COMMANDx and AT+DATACUTx settings are stored in special location, user can use below command to clear them.
1013 1013  
1014 1014  
... ... @@ -1089,13 +1089,13 @@
1089 1089  
1090 1090  
1091 1091  
1092 -1.
1084 +1.
1093 1093  11. Buttons
1094 1094  
1095 1095  |**Button**|**Feature**
1096 1096  |**RST**|Reboot RS485-BL
1097 1097  
1098 -1.
1090 +1.
1099 1099  11. +3V3 Output
1100 1100  
1101 1101  RS485-BL has a Controllable +3V3 output, user can use this output to power external sensor.
... ... @@ -1113,7 +1113,7 @@
1113 1113  By default, the AT+3V3T=0. This is a special case, means the +3V3 output is always on at any time
1114 1114  
1115 1115  
1116 -1.
1108 +1.
1117 1117  11. +5V Output
1118 1118  
1119 1119  RS485-BL has a Controllable +5V output, user can use this output to power external sensor.
... ... @@ -1133,13 +1133,13 @@
1133 1133  
1134 1134  
1135 1135  
1136 -1.
1128 +1.
1137 1137  11. LEDs
1138 1138  
1139 1139  |**LEDs**|**Feature**
1140 1140  |**LED1**|Blink when device transmit a packet.
1141 1141  
1142 -1.
1134 +1.
1143 1143  11. Switch Jumper
1144 1144  
1145 1145  |**Switch Jumper**|**Feature**
... ... @@ -1185,7 +1185,7 @@
1185 1185  
1186 1186  
1187 1187  
1188 -1.
1180 +1.
1189 1189  11. Common AT Command Sequence
1190 1190  111. Multi-channel ABP mode (Use with SX1301/LG308)
1191 1191  
... ... @@ -1204,8 +1204,8 @@
1204 1204  
1205 1205  ATZ
1206 1206  
1207 -1.
1208 -11.
1199 +1.
1200 +11.
1209 1209  111. Single-channel ABP mode (Use with LG01/LG02)
1210 1210  
1211 1211  AT+FDR   Reset Parameters to Factory Default, Keys Reserve
... ... @@ -1280,7 +1280,7 @@
1280 1280  [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image035.png]] [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image036.png]]
1281 1281  
1282 1282  
1283 -1.
1275 +1.
1284 1284  11. How to change the LoRa Frequency Bands/Region?
1285 1285  
1286 1286  User can follow the introduction for [[how to upgrade image>>path:#upgrade_image]]. When download the images, choose the required image file for download.
... ... @@ -1287,7 +1287,7 @@
1287 1287  
1288 1288  
1289 1289  
1290 -1.
1282 +1.
1291 1291  11. How many RS485-Slave can RS485-BL connects?
1292 1292  
1293 1293  The RS485-BL can support max 32 RS485 devices. Each uplink command of RS485-BL can support max 16 different RS485 command. So RS485-BL can support max 16 RS485 devices pre-program in the device for uplink. For other devices no pre-program, user can use the [[downlink message (type code 0xA8) to poll their info>>path:#downlink_A8]].
... ... @@ -1304,7 +1304,7 @@
1304 1304  
1305 1305  
1306 1306  
1307 -1.
1299 +1.
1308 1308  11. Why I can’t join TTN V3 in US915 /AU915 bands?
1309 1309  
1310 1310  It might about the channels mapping. Please see for detail.