Changes for page RS485-BL – Waterproof RS485 to LoRaWAN Converter
Last modified by Xiaoling on 2025/04/23 15:57
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -915,13 +915,12 @@ 915 915 916 916 **AT+MBFUN has only two value:** 917 917 918 -* AT+MBFUN=1: Enable Modbus reading. And get response base on the MODBUS return 918 +* **AT+MBFUN=1**: Enable Modbus reading. And get response base on the MODBUS return 919 919 920 920 AT+MBFUN=1, device can auto read the Modbus function code: 01, 02, 03 or 04. AT+MBFUN has lower priority vs AT+DATACUT command. If AT+DATACUT command is configured, AT+MBFUN will be ignore. 921 921 922 -* AT+MBFUN=0: Disable Modbus fast reading. 922 +* **AT+MBFUN=0**: Disable Modbus fast reading. 923 923 924 - 925 925 **Example:** 926 926 927 927 * AT+MBFUN=1 and AT+DATACUT1/AT+DATACUT2 are not configure (0,0,0). ... ... @@ -931,121 +931,139 @@ 931 931 [[image:1654133913295-597.png]] 932 932 933 933 934 -[[image: file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image026.png]]933 +[[image:1654133954153-643.png]] 935 935 936 936 937 -* Downlink Commands: 936 +* **Downlink Commands:** 938 938 939 -A9 aa - àSame as AT+MBFUN=aa938 +**A9 aa** ~-~-> Same as AT+MBFUN=aa 940 940 941 941 942 -==== RS485 command timeout ==== 943 943 942 +==== **RS485 command timeout** ==== 943 + 944 944 Some Modbus device has slow action to send replies. This command is used to configure the RS485-BL to use longer time to wait for their action. 945 945 946 946 Default value: 0, range: 0 ~~ 5 seconds 947 947 948 948 949 -* AT Command: 949 +* **AT Command:** 950 950 951 -AT+CMDDLaa=hex(bb cc) 951 +(% class="box infomessage" %) 952 +((( 953 +**AT+CMDDLaa=hex(bb cc)** 954 +))) 952 952 953 -Example: 956 +**Example:** 954 954 955 955 **AT+CMDDL1=1000** to send the open time to 1000ms 956 956 957 957 958 -* Downlink Payload: 961 +* **Downlink Payload:** 959 959 960 960 0x AA aa bb cc 961 961 962 962 Same as: AT+CMDDLaa=hex(bb cc) 963 963 964 - Example: 967 + **Example:** 965 965 966 - 0xAA 01 03 E8 àSame as **AT+CMDDL1=1000 ms**969 + **0xAA 01 03 E8** ~-~-> Same as **AT+CMDDL1=1000 ms** 967 967 968 968 969 -==== [[Uplink>>path:#downlink_A8]] payload mode ==== 970 970 973 +==== **Uplink payload mode** ==== 974 + 971 971 Define to use one uplink or multiple uplinks for the sampling. 972 972 973 -The use of this command please see: [[Compose Uplink payload>> path:#DataUP]]977 +The use of this command please see: [[Compose Uplink payload>>||anchor="H3.3.4Composetheuplinkpayload"]] 974 974 975 -* AT Command: 979 +* **AT Command:** 976 976 977 -AT+DATAUP=0 981 +(% class="box infomessage" %) 982 +((( 983 +**AT+DATAUP=0** 984 +))) 978 978 979 -AT+DATAUP=1 986 +(% class="box infomessage" %) 987 +((( 988 +**AT+DATAUP=1** 989 +))) 980 980 981 981 982 -* Downlink Payload: 992 +* **Downlink Payload:** 983 983 984 -0xAD 00 àSame as AT+DATAUP=0994 +**0xAD 00** **~-~->** Same as AT+DATAUP=0 985 985 986 -0xAD 01 àSame as AT+DATAUP=1996 +**0xAD 01** **~-~->** Same as AT+DATAUP=1 987 987 988 988 989 -==== Manually trigger an Uplink ==== 990 990 1000 +==== **Manually trigger an Uplink** ==== 1001 + 991 991 Ask device to send an uplink immediately. 992 992 993 -* Downlink Payload: 1004 +* **Downlink Payload:** 994 994 995 -0x08 FF, RS485-BL will immediately send an uplink. 1006 +**0x08 FF**, RS485-BL will immediately send an uplink. 996 996 997 997 998 -==== Clear RS485 Command ==== 999 999 1010 +==== **Clear RS485 Command** ==== 1011 + 1000 1000 The AT+COMMANDx and AT+DATACUTx settings are stored in special location, user can use below command to clear them. 1001 1001 1002 1002 1003 -* AT Command: 1015 +* **AT Command:** 1004 1004 1005 -**AT+CMDEAR=mm,nn** 1017 +(% style="color:#037691" %)**AT+CMDEAR=mm,nn** (%%) mm: start position of erase ,nn: stop position of erase Etc. AT+CMDEAR=1,10 means erase AT+COMMAND1/AT+DATACUT1 to AT+COMMAND10/AT+DATACUT10 1006 1006 1007 -Etc. AT+CMDEAR=1,10 means erase AT+COMMAND1/AT+DATACUT1 to AT+COMMAND10/AT+DATACUT10 1008 - 1009 1009 Example screen shot after clear all RS485 commands. 1010 1010 1011 1011 1012 - 1013 1013 The uplink screen shot is: 1014 1014 1015 -[[image: file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image023.png]]1024 +[[image:1654134704555-320.png]] 1016 1016 1017 1017 1018 -* Downlink Payload: 1027 +* **Downlink Payload:** 1019 1019 1020 -0x09 aa bb same as AT+CMDEAR=aa,bb 1029 +**0x09 aa bb** same as AT+CMDEAR=aa,bb 1021 1021 1022 1022 1023 -==== Set Serial Communication Parameters ==== 1024 1024 1033 +==== **Set Serial Communication Parameters** ==== 1034 + 1025 1025 Set the Rs485 serial communication parameters: 1026 1026 1027 -* AT Command: 1037 +* **AT Command:** 1028 1028 1029 1029 Set Baud Rate: 1030 1030 1031 -AT+BAUDR=9600 ~/~/ Options: (1200,2400,4800,14400,19200,115200) 1041 +(% class="box infomessage" %) 1042 +((( 1043 +**AT+BAUDR=9600** ~/~/ Options: (1200,2400,4800,14400,19200,115200) 1044 +))) 1032 1032 1046 +Set UART Parity 1033 1033 1034 -Set UART parity 1048 +(% class="box infomessage" %) 1049 +((( 1050 +**AT+PARITY=0** ~/~/ Option: 0: no parity, 1: odd parity, 2: even parity 1051 +))) 1035 1035 1036 -AT+PARITY=0 ~/~/ Option: 0: no parity, 1: odd parity, 2: even parity 1037 - 1038 - 1039 1039 Set STOPBIT 1040 1040 1041 -AT+STOPBIT=0 ~/~/ Option: 0 for 1bit; 1 for 1.5 bit ; 2 for 2 bits 1055 +(% class="box infomessage" %) 1056 +((( 1057 +**AT+STOPBIT=0** ~/~/ Option: 0 for 1bit; 1 for 1.5 bit ; 2 for 2 bits 1058 +))) 1042 1042 1043 1043 1044 -* Downlink Payload: 1061 +* **Downlink Payload:** 1045 1045 1046 -A7 01 aa bb: Same AT+BAUDR=hex(aa bb)*100 1063 +**A7 01 aa bb**: Same AT+BAUDR=hex(aa bb)*100 1047 1047 1048 -Example: 1065 +**Example:** 1049 1049 1050 1050 * A7 01 00 60 same as AT+BAUDR=9600 1051 1051 * A7 01 04 80 same as AT+BAUDR=115200 ... ... @@ -1055,8 +1055,9 @@ 1055 1055 A7 03 aa: Same as AT+STOPBIT=aa (aa value: 00 , 01 or 02) 1056 1056 1057 1057 1058 -==== Control output power duration ==== 1059 1059 1076 +==== **Control output power duration** ==== 1077 + 1060 1060 User can set the output power duration before each sampling. 1061 1061 1062 1062 * AT Command:
- 1654134704555-320.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +91.4 KB - Content