... ... @@ -895,9 +895,9 @@
895 895  (% style="color:#037691" %)**AF 03 02 06 **(% style="color:orange" %)**0B**(% style="color:red" %)** 02 **(% style="color:green" %)**05 07 08 0A **(% style="color:#037691" %)**00**(%%): Same as AT+DATACUT3=(% style="color:orange" %)**11**(%%),(% style="color:red" %)**2**(%%),(% style="color:green" %)**5~~7+8~~10**
896 896  
897 897  
898 -**0xAB** downlink command can be used for set AT+SEARCHx
898 +0xAB downlink command can be used for set AT+SEARCHx
899 899  
900 -**Example:** **AB aa 01 03 xx xx xx** (03 here means there are total 3 bytes after 03) So
900 +Example: **AB aa 01 03 xx xx xx** (03 here means there are total 3 bytes after 03) So
901 901  
902 902  * AB aa 01 03 xx xx xx  same as AT+SEARCHaa=1,xx xx xx
903 903  * AB aa 02 03 xx xx xx 02 yy yy(03 means there are 3 bytes after 03, they are xx xx xx;02 means there are 2 bytes after 02, they are yy yy) so the commands
... ... @@ -905,15 +905,14 @@
905 905  **AB aa 02 03 xx xx xx 02 yy yy**  same as **AT+SEARCHaa=2,xx xx xx+yy yy**
906 906  
907 907  
908 +==== Fast command to handle MODBUS device ====
908 908  
909 -==== **Fast command to handle MODBUS device** ====
910 -
911 911  AT+MBFUN is valid since v1.3 firmware version. The command is for fast configure to read Modbus devices. It is only valid for the devices which follow the [[MODBUS-RTU protocol>>url:https://www.modbustools.com/modbus.html]].
912 912  
913 913  This command is valid since v1.3 firmware version
914 914  
915 915  
916 -**AT+MBFUN has only two value:**
915 +AT+MBFUN has only two value:
917 917  
918 918  * AT+MBFUN=1: Enable Modbus reading. And get response base on the MODBUS return
919 919  
... ... @@ -921,14 +921,13 @@
921 921  
922 922  * AT+MBFUN=0: Disable Modbus fast reading.
923 923  
923 +Example:
924 924  
925 -**Example:**
926 -
927 927  * AT+MBFUN=1 and AT+DATACUT1/AT+DATACUT2 are not configure (0,0,0).
928 928  * AT+COMMAND1= 01 03 00 10 00 08,1 ~-~-> read slave address 01 , function code 03, start address 00 01, quantity of registers 00 08.
929 929  * AT+COMMAND2= 01 02 00 40 00 10,1 ~-~-> read slave address 01 , function code 02, start address 00 40, quantity of inputs 00 10.
930 930  
931 -[[image:1654133913295-597.png]]
929 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image025.png]]
932 932  
933 933  
934 934  [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image026.png]]
1654133913295-597.png