Changes for page RS485-BL – Waterproof RS485 to LoRaWAN Converter
Last modified by Xiaoling on 2025/04/23 15:57
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 3 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -906,7 +906,7 @@ 906 906 907 907 908 908 909 -==== Fast command to handle MODBUS device ==== 909 +==== **Fast command to handle MODBUS device** ==== 910 910 911 911 AT+MBFUN is valid since v1.3 firmware version. The command is for fast configure to read Modbus devices. It is only valid for the devices which follow the [[MODBUS-RTU protocol>>url:https://www.modbustools.com/modbus.html]]. 912 912 ... ... @@ -913,138 +913,156 @@ 913 913 This command is valid since v1.3 firmware version 914 914 915 915 916 -AT+MBFUN has only two value: 916 +**AT+MBFUN has only two value:** 917 917 918 -* AT+MBFUN=1: Enable Modbus reading. And get response base on the MODBUS return 918 +* **AT+MBFUN=1**: Enable Modbus reading. And get response base on the MODBUS return 919 919 920 920 AT+MBFUN=1, device can auto read the Modbus function code: 01, 02, 03 or 04. AT+MBFUN has lower priority vs AT+DATACUT command. If AT+DATACUT command is configured, AT+MBFUN will be ignore. 921 921 922 -* AT+MBFUN=0: Disable Modbus fast reading. 922 +* **AT+MBFUN=0**: Disable Modbus fast reading. 923 923 924 -Example: 924 +**Example:** 925 925 926 926 * AT+MBFUN=1 and AT+DATACUT1/AT+DATACUT2 are not configure (0,0,0). 927 927 * AT+COMMAND1= 01 03 00 10 00 08,1 ~-~-> read slave address 01 , function code 03, start address 00 01, quantity of registers 00 08. 928 928 * AT+COMMAND2= 01 02 00 40 00 10,1 ~-~-> read slave address 01 , function code 02, start address 00 40, quantity of inputs 00 10. 929 929 930 -[[image: file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image025.png]]930 +[[image:1654133913295-597.png]] 931 931 932 932 933 -[[image: file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image026.png]]933 +[[image:1654133954153-643.png]] 934 934 935 935 936 -* Downlink Commands: 936 +* **Downlink Commands:** 937 937 938 -A9 aa - àSame as AT+MBFUN=aa938 +**A9 aa** ~-~-> Same as AT+MBFUN=aa 939 939 940 940 941 -==== RS485 command timeout ==== 942 942 942 +==== **RS485 command timeout** ==== 943 + 943 943 Some Modbus device has slow action to send replies. This command is used to configure the RS485-BL to use longer time to wait for their action. 944 944 945 945 Default value: 0, range: 0 ~~ 5 seconds 946 946 947 947 948 -* AT Command: 949 +* **AT Command:** 949 949 950 -AT+CMDDLaa=hex(bb cc) 951 +(% class="box infomessage" %) 952 +((( 953 +**AT+CMDDLaa=hex(bb cc)** 954 +))) 951 951 952 -Example: 956 +**Example:** 953 953 954 954 **AT+CMDDL1=1000** to send the open time to 1000ms 955 955 956 956 957 -* Downlink Payload: 961 +* **Downlink Payload:** 958 958 959 959 0x AA aa bb cc 960 960 961 961 Same as: AT+CMDDLaa=hex(bb cc) 962 962 963 - Example: 967 + **Example:** 964 964 965 - 0xAA 01 03 E8 àSame as **AT+CMDDL1=1000 ms**969 + **0xAA 01 03 E8** ~-~-> Same as **AT+CMDDL1=1000 ms** 966 966 967 967 968 -==== [[Uplink>>path:#downlink_A8]] payload mode ==== 969 969 973 +==== **Uplink payload mode** ==== 974 + 970 970 Define to use one uplink or multiple uplinks for the sampling. 971 971 972 -The use of this command please see: [[Compose Uplink payload>> path:#DataUP]]977 +The use of this command please see: [[Compose Uplink payload>>||anchor="H3.3.4Composetheuplinkpayload"]] 973 973 974 -* AT Command: 979 +* **AT Command:** 975 975 976 -AT+DATAUP=0 981 +(% class="box infomessage" %) 982 +((( 983 +**AT+DATAUP=0** 984 +))) 977 977 978 -AT+DATAUP=1 986 +(% class="box infomessage" %) 987 +((( 988 +**AT+DATAUP=1** 989 +))) 979 979 980 980 981 -* Downlink Payload: 992 +* **Downlink Payload:** 982 982 983 -0xAD 00 àSame as AT+DATAUP=0994 +**0xAD 00** **~-~->** Same as AT+DATAUP=0 984 984 985 -0xAD 01 àSame as AT+DATAUP=1996 +**0xAD 01** **~-~->** Same as AT+DATAUP=1 986 986 987 987 988 -==== Manually trigger an Uplink ==== 989 989 1000 +==== **Manually trigger an Uplink** ==== 1001 + 990 990 Ask device to send an uplink immediately. 991 991 992 -* Downlink Payload: 1004 +* **Downlink Payload:** 993 993 994 -0x08 FF, RS485-BL will immediately send an uplink. 1006 +**0x08 FF**, RS485-BL will immediately send an uplink. 995 995 996 996 997 -==== Clear RS485 Command ==== 998 998 1010 +==== **Clear RS485 Command** ==== 1011 + 999 999 The AT+COMMANDx and AT+DATACUTx settings are stored in special location, user can use below command to clear them. 1000 1000 1001 1001 1002 -* AT Command: 1015 +* **AT Command:** 1003 1003 1004 -**AT+CMDEAR=mm,nn** 1017 +(% style="color:#037691" %)**AT+CMDEAR=mm,nn** (%%) mm: start position of erase ,nn: stop position of erase Etc. AT+CMDEAR=1,10 means erase AT+COMMAND1/AT+DATACUT1 to AT+COMMAND10/AT+DATACUT10 1005 1005 1006 -Etc. AT+CMDEAR=1,10 means erase AT+COMMAND1/AT+DATACUT1 to AT+COMMAND10/AT+DATACUT10 1007 - 1008 1008 Example screen shot after clear all RS485 commands. 1009 1009 1010 1010 1011 - 1012 1012 The uplink screen shot is: 1013 1013 1014 -[[image: file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image023.png]]1024 +[[image:1654134704555-320.png]] 1015 1015 1016 1016 1017 -* Downlink Payload: 1027 +* **Downlink Payload:** 1018 1018 1019 -0x09 aa bb same as AT+CMDEAR=aa,bb 1029 +**0x09 aa bb** same as AT+CMDEAR=aa,bb 1020 1020 1021 1021 1022 -==== Set Serial Communication Parameters ==== 1023 1023 1033 +==== **Set Serial Communication Parameters** ==== 1034 + 1024 1024 Set the Rs485 serial communication parameters: 1025 1025 1026 -* AT Command: 1037 +* **AT Command:** 1027 1027 1028 1028 Set Baud Rate: 1029 1029 1030 -AT+BAUDR=9600 ~/~/ Options: (1200,2400,4800,14400,19200,115200) 1041 +(% class="box infomessage" %) 1042 +((( 1043 +**AT+BAUDR=9600** ~/~/ Options: (1200,2400,4800,14400,19200,115200) 1044 +))) 1031 1031 1046 +Set UART Parity 1032 1032 1033 -Set UART parity 1048 +(% class="box infomessage" %) 1049 +((( 1050 +**AT+PARITY=0** ~/~/ Option: 0: no parity, 1: odd parity, 2: even parity 1051 +))) 1034 1034 1035 -AT+PARITY=0 ~/~/ Option: 0: no parity, 1: odd parity, 2: even parity 1036 - 1037 - 1038 1038 Set STOPBIT 1039 1039 1040 -AT+STOPBIT=0 ~/~/ Option: 0 for 1bit; 1 for 1.5 bit ; 2 for 2 bits 1055 +(% class="box infomessage" %) 1056 +((( 1057 +**AT+STOPBIT=0** ~/~/ Option: 0 for 1bit; 1 for 1.5 bit ; 2 for 2 bits 1058 +))) 1041 1041 1042 1042 1043 -* Downlink Payload: 1061 +* **Downlink Payload:** 1044 1044 1045 -A7 01 aa bb: Same AT+BAUDR=hex(aa bb)*100 1063 +**A7 01 aa bb**: Same AT+BAUDR=hex(aa bb)*100 1046 1046 1047 -Example: 1065 +**Example:** 1048 1048 1049 1049 * A7 01 00 60 same as AT+BAUDR=9600 1050 1050 * A7 01 04 80 same as AT+BAUDR=115200 ... ... @@ -1054,8 +1054,9 @@ 1054 1054 A7 03 aa: Same as AT+STOPBIT=aa (aa value: 00 , 01 or 02) 1055 1055 1056 1056 1057 -==== Control output power duration ==== 1058 1058 1076 +==== **Control output power duration** ==== 1077 + 1059 1059 User can set the output power duration before each sampling. 1060 1060 1061 1061 * AT Command:
- 1654133913295-597.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +116.2 KB - Content
- 1654133954153-643.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +91.2 KB - Content
- 1654134704555-320.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +91.4 KB - Content