Changes for page RS485-BL – Waterproof RS485 to LoRaWAN Converter
Last modified by Xiaoling on 2025/04/23 15:57
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 2 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -906,7 +906,7 @@ 906 906 907 907 908 908 909 -==== Fast command to handle MODBUS device ==== 909 +==== **Fast command to handle MODBUS device** ==== 910 910 911 911 AT+MBFUN is valid since v1.3 firmware version. The command is for fast configure to read Modbus devices. It is only valid for the devices which follow the [[MODBUS-RTU protocol>>url:https://www.modbustools.com/modbus.html]]. 912 912 ... ... @@ -913,76 +913,87 @@ 913 913 This command is valid since v1.3 firmware version 914 914 915 915 916 -AT+MBFUN has only two value: 916 +**AT+MBFUN has only two value:** 917 917 918 -* AT+MBFUN=1: Enable Modbus reading. And get response base on the MODBUS return 918 +* **AT+MBFUN=1**: Enable Modbus reading. And get response base on the MODBUS return 919 919 920 920 AT+MBFUN=1, device can auto read the Modbus function code: 01, 02, 03 or 04. AT+MBFUN has lower priority vs AT+DATACUT command. If AT+DATACUT command is configured, AT+MBFUN will be ignore. 921 921 922 -* AT+MBFUN=0: Disable Modbus fast reading. 922 +* **AT+MBFUN=0**: Disable Modbus fast reading. 923 923 924 -Example: 924 +**Example:** 925 925 926 926 * AT+MBFUN=1 and AT+DATACUT1/AT+DATACUT2 are not configure (0,0,0). 927 927 * AT+COMMAND1= 01 03 00 10 00 08,1 ~-~-> read slave address 01 , function code 03, start address 00 01, quantity of registers 00 08. 928 928 * AT+COMMAND2= 01 02 00 40 00 10,1 ~-~-> read slave address 01 , function code 02, start address 00 40, quantity of inputs 00 10. 929 929 930 -[[image: file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image025.png]]930 +[[image:1654133913295-597.png]] 931 931 932 932 933 -[[image: file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image026.png]]933 +[[image:1654133954153-643.png]] 934 934 935 935 936 -* Downlink Commands: 936 +* **Downlink Commands:** 937 937 938 -A9 aa - àSame as AT+MBFUN=aa938 +**A9 aa** ~-~-> Same as AT+MBFUN=aa 939 939 940 940 941 -==== RS485 command timeout ==== 942 942 942 +==== **RS485 command timeout** ==== 943 + 943 943 Some Modbus device has slow action to send replies. This command is used to configure the RS485-BL to use longer time to wait for their action. 944 944 945 945 Default value: 0, range: 0 ~~ 5 seconds 946 946 947 947 948 -* AT Command: 949 +* **AT Command:** 949 949 950 -AT+CMDDLaa=hex(bb cc) 951 +(% class="box infomessage" %) 952 +((( 953 +**AT+CMDDLaa=hex(bb cc)** 954 +))) 951 951 952 -Example: 956 +**Example:** 953 953 954 954 **AT+CMDDL1=1000** to send the open time to 1000ms 955 955 956 956 957 -* Downlink Payload: 961 +* **Downlink Payload:** 958 958 959 959 0x AA aa bb cc 960 960 961 961 Same as: AT+CMDDLaa=hex(bb cc) 962 962 963 - Example: 967 + **Example:** 964 964 965 - 0xAA 01 03 E8 àSame as **AT+CMDDL1=1000 ms**969 + **0xAA 01 03 E8** ~-~-> Same as **AT+CMDDL1=1000 ms** 966 966 967 967 968 -==== [[Uplink>>path:#downlink_A8]] payload mode ==== 969 969 973 +==== **Uplink payload mode** ==== 974 + 970 970 Define to use one uplink or multiple uplinks for the sampling. 971 971 972 -The use of this command please see: [[Compose Uplink payload>> path:#DataUP]]977 +The use of this command please see: [[Compose Uplink payload>>||anchor="H3.3.4Composetheuplinkpayload"]] 973 973 974 -* AT Command: 979 +* **AT Command:** 975 975 976 -AT+DATAUP=0 981 +(% class="box infomessage" %) 982 +((( 983 +**AT+DATAUP=0** 984 +))) 977 977 978 -AT+DATAUP=1 986 +(% class="box infomessage" %) 987 +((( 988 +**AT+DATAUP=1** 989 +))) 979 979 980 980 981 -* Downlink Payload: 992 +* **Downlink Payload:** 982 982 983 -0xAD 00 àSame as AT+DATAUP=0994 +0xAD 00 **~-~->** Same as AT+DATAUP=0 984 984 985 -0xAD 01 àSame as AT+DATAUP=1996 +0xAD 01 **~-~->** Same as AT+DATAUP=1 986 986 987 987 988 988 ==== Manually trigger an Uplink ==== ... ... @@ -1076,13 +1076,13 @@ 1076 1076 1077 1077 1078 1078 1079 -1. 1090 +1. 1080 1080 11. Buttons 1081 1081 1082 1082 |**Button**|**Feature** 1083 1083 |**RST**|Reboot RS485-BL 1084 1084 1085 -1. 1096 +1. 1086 1086 11. +3V3 Output 1087 1087 1088 1088 RS485-BL has a Controllable +3V3 output, user can use this output to power external sensor. ... ... @@ -1100,7 +1100,7 @@ 1100 1100 By default, the AT+3V3T=0. This is a special case, means the +3V3 output is always on at any time 1101 1101 1102 1102 1103 -1. 1114 +1. 1104 1104 11. +5V Output 1105 1105 1106 1106 RS485-BL has a Controllable +5V output, user can use this output to power external sensor. ... ... @@ -1120,13 +1120,13 @@ 1120 1120 1121 1121 1122 1122 1123 -1. 1134 +1. 1124 1124 11. LEDs 1125 1125 1126 1126 |**LEDs**|**Feature** 1127 1127 |**LED1**|Blink when device transmit a packet. 1128 1128 1129 -1. 1140 +1. 1130 1130 11. Switch Jumper 1131 1131 1132 1132 |**Switch Jumper**|**Feature** ... ... @@ -1172,7 +1172,7 @@ 1172 1172 1173 1173 1174 1174 1175 -1. 1186 +1. 1176 1176 11. Common AT Command Sequence 1177 1177 111. Multi-channel ABP mode (Use with SX1301/LG308) 1178 1178 ... ... @@ -1191,8 +1191,8 @@ 1191 1191 1192 1192 ATZ 1193 1193 1194 -1. 1195 -11. 1205 +1. 1206 +11. 1196 1196 111. Single-channel ABP mode (Use with LG01/LG02) 1197 1197 1198 1198 AT+FDR Reset Parameters to Factory Default, Keys Reserve ... ... @@ -1267,7 +1267,7 @@ 1267 1267 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image035.png]] [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image036.png]] 1268 1268 1269 1269 1270 -1. 1281 +1. 1271 1271 11. How to change the LoRa Frequency Bands/Region? 1272 1272 1273 1273 User can follow the introduction for [[how to upgrade image>>path:#upgrade_image]]. When download the images, choose the required image file for download. ... ... @@ -1274,7 +1274,7 @@ 1274 1274 1275 1275 1276 1276 1277 -1. 1288 +1. 1278 1278 11. How many RS485-Slave can RS485-BL connects? 1279 1279 1280 1280 The RS485-BL can support max 32 RS485 devices. Each uplink command of RS485-BL can support max 16 different RS485 command. So RS485-BL can support max 16 RS485 devices pre-program in the device for uplink. For other devices no pre-program, user can use the [[downlink message (type code 0xA8) to poll their info>>path:#downlink_A8]]. ... ... @@ -1291,7 +1291,7 @@ 1291 1291 1292 1292 1293 1293 1294 -1. 1305 +1. 1295 1295 11. Why I can’t join TTN V3 in US915 /AU915 bands? 1296 1296 1297 1297 It might about the channels mapping. Please see for detail.
- 1654133913295-597.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +116.2 KB - Content
- 1654133954153-643.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +91.2 KB - Content