Changes for page RS485-BL – Waterproof RS485 to LoRaWAN Converter
Last modified by Xiaoling on 2025/04/23 15:57
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 2 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -906,7 +906,7 @@ 906 906 907 907 908 908 909 -==== Fast command to handle MODBUS device ==== 909 +==== **Fast command to handle MODBUS device** ==== 910 910 911 911 AT+MBFUN is valid since v1.3 firmware version. The command is for fast configure to read Modbus devices. It is only valid for the devices which follow the [[MODBUS-RTU protocol>>url:https://www.modbustools.com/modbus.html]]. 912 912 ... ... @@ -913,31 +913,33 @@ 913 913 This command is valid since v1.3 firmware version 914 914 915 915 916 -AT+MBFUN has only two value: 916 +**AT+MBFUN has only two value:** 917 917 918 -* AT+MBFUN=1: Enable Modbus reading. And get response base on the MODBUS return 918 +* **AT+MBFUN=1**: Enable Modbus reading. And get response base on the MODBUS return 919 919 920 920 AT+MBFUN=1, device can auto read the Modbus function code: 01, 02, 03 or 04. AT+MBFUN has lower priority vs AT+DATACUT command. If AT+DATACUT command is configured, AT+MBFUN will be ignore. 921 921 922 -* AT+MBFUN=0: Disable Modbus fast reading. 922 +* **AT+MBFUN=0**: Disable Modbus fast reading. 923 923 924 -Example: 925 925 925 +**Example:** 926 + 926 926 * AT+MBFUN=1 and AT+DATACUT1/AT+DATACUT2 are not configure (0,0,0). 927 927 * AT+COMMAND1= 01 03 00 10 00 08,1 ~-~-> read slave address 01 , function code 03, start address 00 01, quantity of registers 00 08. 928 928 * AT+COMMAND2= 01 02 00 40 00 10,1 ~-~-> read slave address 01 , function code 02, start address 00 40, quantity of inputs 00 10. 929 929 930 -[[image: file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image025.png]]931 +[[image:1654133913295-597.png]] 931 931 932 932 933 -[[image: file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image026.png]]934 +[[image:1654133954153-643.png]] 934 934 935 935 936 -* Downlink Commands: 937 +* **Downlink Commands:** 937 937 938 -A9 aa - àSame as AT+MBFUN=aa939 +**A9 aa** ~-~-> Same as AT+MBFUN=aa 939 939 940 940 942 + 941 941 ==== RS485 command timeout ==== 942 942 943 943 Some Modbus device has slow action to send replies. This command is used to configure the RS485-BL to use longer time to wait for their action.
- 1654133913295-597.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +116.2 KB - Content
- 1654133954153-643.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +91.2 KB - Content