Last modified by Xiaoling on 2025/04/23 15:57

From version 30.7
edited by Xiaoling
on 2022/06/02 09:35
Change comment: There is no comment for this version
To version 33.3
edited by Xiaoling
on 2022/06/02 09:56
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -895,9 +895,9 @@
895 895  (% style="color:#037691" %)**AF 03 02 06 **(% style="color:orange" %)**0B**(% style="color:red" %)** 02 **(% style="color:green" %)**05 07 08 0A **(% style="color:#037691" %)**00**(%%): Same as AT+DATACUT3=(% style="color:orange" %)**11**(%%),(% style="color:red" %)**2**(%%),(% style="color:green" %)**5~~7+8~~10**
896 896  
897 897  
898 -0xAB downlink command can be used for set AT+SEARCHx
898 +**0xAB** downlink command can be used for set AT+SEARCHx
899 899  
900 -Example: **AB aa 01 03 xx xx xx** (03 here means there are total 3 bytes after 03) So
900 +**Example:** **AB aa 01 03 xx xx xx** (03 here means there are total 3 bytes after 03) So
901 901  
902 902  * AB aa 01 03 xx xx xx  same as AT+SEARCHaa=1,xx xx xx
903 903  * AB aa 02 03 xx xx xx 02 yy yy(03 means there are 3 bytes after 03, they are xx xx xx;02 means there are 2 bytes after 02, they are yy yy) so the commands
... ... @@ -905,145 +905,164 @@
905 905  **AB aa 02 03 xx xx xx 02 yy yy**  same as **AT+SEARCHaa=2,xx xx xx+yy yy**
906 906  
907 907  
908 -==== Fast command to handle MODBUS device ====
909 909  
909 +==== **Fast command to handle MODBUS device** ====
910 +
910 910  AT+MBFUN is valid since v1.3 firmware version. The command is for fast configure to read Modbus devices. It is only valid for the devices which follow the [[MODBUS-RTU protocol>>url:https://www.modbustools.com/modbus.html]].
911 911  
912 912  This command is valid since v1.3 firmware version
913 913  
914 914  
915 -AT+MBFUN has only two value:
916 +**AT+MBFUN has only two value:**
916 916  
917 -* AT+MBFUN=1: Enable Modbus reading. And get response base on the MODBUS return
918 +* **AT+MBFUN=1**: Enable Modbus reading. And get response base on the MODBUS return
918 918  
919 919  AT+MBFUN=1, device can auto read the Modbus function code: 01, 02, 03 or 04. AT+MBFUN has lower priority vs AT+DATACUT command. If AT+DATACUT command is configured, AT+MBFUN will be ignore.
920 920  
921 -* AT+MBFUN=0: Disable Modbus fast reading.
922 +* **AT+MBFUN=0**: Disable Modbus fast reading.
922 922  
923 -Example:
924 +**Example:**
924 924  
925 925  * AT+MBFUN=1 and AT+DATACUT1/AT+DATACUT2 are not configure (0,0,0).
926 926  * AT+COMMAND1= 01 03 00 10 00 08,1 ~-~-> read slave address 01 , function code 03, start address 00 01, quantity of registers 00 08.
927 927  * AT+COMMAND2= 01 02 00 40 00 10,1 ~-~-> read slave address 01 , function code 02, start address 00 40, quantity of inputs 00 10.
928 928  
929 -[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image025.png]]
930 +[[image:1654133913295-597.png]]
930 930  
931 931  
932 -[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image026.png]]
933 +[[image:1654133954153-643.png]]
933 933  
934 934  
935 -* Downlink Commands:
936 +* **Downlink Commands:**
936 936  
937 -A9 aa -à Same as AT+MBFUN=aa
938 +**A9 aa** ~-~-> Same as AT+MBFUN=aa
938 938  
939 939  
940 -==== RS485 command timeout ====
941 941  
942 +==== **RS485 command timeout** ====
943 +
942 942  Some Modbus device has slow action to send replies. This command is used to configure the RS485-BL to use longer time to wait for their action.
943 943  
944 944  Default value: 0, range:  0 ~~ 5 seconds
945 945  
946 946  
947 -* AT Command:
949 +* **AT Command:**
948 948  
949 -AT+CMDDLaa=hex(bb cc)
951 +(% class="box infomessage" %)
952 +(((
953 +**AT+CMDDLaa=hex(bb cc)**
954 +)))
950 950  
951 -Example:
956 +**Example:**
952 952  
953 953  **AT+CMDDL1=1000** to send the open time to 1000ms
954 954  
955 955  
956 -* Downlink Payload:
961 +* **Downlink Payload:**
957 957  
958 958  0x AA aa bb cc
959 959  
960 960  Same as: AT+CMDDLaa=hex(bb cc)
961 961  
962 - Example:
967 + **Example:**
963 963  
964 - 0xAA 01 03 E8  à Same as **AT+CMDDL1=1000 ms**
969 + **0xAA 01 03 E8**  ~-~-> Same as **AT+CMDDL1=1000 ms**
965 965  
966 966  
967 -==== [[Uplink>>path:#downlink_A8]] payload mode ====
968 968  
973 +==== **Uplink payload mode** ====
974 +
969 969  Define to use one uplink or multiple uplinks for the sampling.
970 970  
971 -The use of this command please see: [[Compose Uplink payload>>path:#DataUP]]
977 +The use of this command please see: [[Compose Uplink payload>>||anchor="H3.3.4Composetheuplinkpayload"]]
972 972  
973 -* AT Command:
979 +* **AT Command:**
974 974  
975 -AT+DATAUP=0
981 +(% class="box infomessage" %)
982 +(((
983 +**AT+DATAUP=0**
984 +)))
976 976  
977 -AT+DATAUP=1
986 +(% class="box infomessage" %)
987 +(((
988 +**AT+DATAUP=1**
989 +)))
978 978  
979 979  
980 -* Downlink Payload:
992 +* **Downlink Payload:**
981 981  
982 -0xAD 00   à Same as AT+DATAUP=0
994 +**0xAD 00**  **~-~->** Same as AT+DATAUP=0
983 983  
984 -0xAD 01   à Same as AT+DATAUP=1
996 +**0xAD 01**  **~-~->** Same as AT+DATAUP=1
985 985  
986 986  
987 -==== Manually trigger an Uplink ====
988 988  
1000 +==== **Manually trigger an Uplink** ====
1001 +
989 989  Ask device to send an uplink immediately.
990 990  
991 -* Downlink Payload:
1004 +* **Downlink Payload:**
992 992  
993 -0x08 FF, RS485-BL will immediately send an uplink.
1006 +**0x08 FF**, RS485-BL will immediately send an uplink.
994 994  
995 995  
996 -==== Clear RS485 Command ====
997 997  
1010 +==== **Clear RS485 Command** ====
1011 +
998 998  The AT+COMMANDx and AT+DATACUTx settings are stored in special location, user can use below command to clear them.
999 999  
1000 1000  
1001 -* AT Command:
1015 +* **AT Command:**
1002 1002  
1003 -**AT+CMDEAR=mm,nn**   mm: start position of erase ,nn: stop position of erase
1017 +(% style="color:#037691" %)**AT+CMDEAR=mm,nn** (%%) mm: start position of erase ,nn: stop position of erase Etc. AT+CMDEAR=1,10 means erase AT+COMMAND1/AT+DATACUT1 to AT+COMMAND10/AT+DATACUT10
1004 1004  
1005 -Etc. AT+CMDEAR=1,10 means erase AT+COMMAND1/AT+DATACUT1 to AT+COMMAND10/AT+DATACUT10
1006 -
1007 1007  Example screen shot after clear all RS485 commands. 
1008 1008  
1009 1009  
1010 -
1011 1011  The uplink screen shot is:
1012 1012  
1013 -[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image023.png]]
1024 +[[image:1654134704555-320.png]]
1014 1014  
1015 1015  
1016 -* Downlink Payload:
1027 +* **Downlink Payload:**
1017 1017  
1018 -0x09 aa bb same as AT+CMDEAR=aa,bb
1029 +**0x09 aa bb** same as AT+CMDEAR=aa,bb
1019 1019  
1020 1020  
1021 -==== Set Serial Communication Parameters ====
1022 1022  
1033 +==== **Set Serial Communication Parameters** ====
1034 +
1023 1023  Set the Rs485 serial communication parameters:
1024 1024  
1025 -* AT Command:
1037 +* **AT Command:**
1026 1026  
1027 1027  Set Baud Rate:
1028 1028  
1029 -AT+BAUDR=9600    ~/~/ Options: (1200,2400,4800,14400,19200,115200)
1041 +(% class="box infomessage" %)
1042 +(((
1043 +**AT+BAUDR=9600**    ~/~/ Options: (1200,2400,4800,14400,19200,115200)
1044 +)))
1030 1030  
1046 +Set UART Parity
1031 1031  
1032 -Set UART parity
1048 +(% class="box infomessage" %)
1049 +(((
1050 +**AT+PARITY=0**    ~/~/ Option: 0: no parity, 1: odd parity, 2: even parity
1051 +)))
1033 1033  
1034 -AT+PARITY=0    ~/~/ Option: 0: no parity, 1: odd parity, 2: even parity
1035 -
1036 -
1037 1037  Set STOPBIT
1038 1038  
1039 -AT+STOPBIT=0    ~/~/ Option: 0 for 1bit; 1 for 1.5 bit ; 2 for 2 bits
1055 +(% class="box infomessage" %)
1056 +(((
1057 +**AT+STOPBIT=0**    ~/~/ Option: 0 for 1bit; 1 for 1.5 bit ; 2 for 2 bits
1058 +)))
1040 1040  
1041 1041  
1042 -* Downlink Payload:
1061 +* **Downlink Payload:**
1043 1043  
1044 -A7 01 aa bb: Same  AT+BAUDR=hex(aa bb)*100
1063 +**A7 01 aa bb**: Same  AT+BAUDR=hex(aa bb)*100
1045 1045  
1046 -Example:
1065 +**Example:**
1047 1047  
1048 1048  * A7 01 00 60   same as AT+BAUDR=9600
1049 1049  * A7 01 04 80  same as AT+BAUDR=115200
... ... @@ -1053,24 +1053,25 @@
1053 1053  A7 03 aa: Same as  AT+STOPBIT=aa  (aa value: 00 , 01 or 02)
1054 1054  
1055 1055  
1056 -==== Control output power duration ====
1057 1057  
1076 +==== **Control output power duration** ====
1077 +
1058 1058  User can set the output power duration before each sampling.
1059 1059  
1060 -* AT Command:
1080 +* **AT Command:**
1061 1061  
1062 -Example:
1082 +**Example:**
1063 1063  
1064 -AT+3V3T=1000 ~/~/ 3V3 output power will open 1s before each sampling.
1084 +**AT+3V3T=1000**  ~/~/ 3V3 output power will open 1s before each sampling.
1065 1065  
1066 -AT+5VT=1000 ~/~/ +5V output power will open 1s before each sampling.
1086 +**AT+5VT=1000**  ~/~/ +5V output power will open 1s before each sampling.
1067 1067  
1068 1068  
1069 -* LoRaWAN Downlink Command:
1089 +* **LoRaWAN Downlink Command:**
1070 1070  
1071 -07 01 aa bb  Same as AT+5VT=(aa bb)
1091 +**07 01 aa bb**  Same as AT+5VT=(aa bb)
1072 1072  
1073 -07 02 aa bb  Same as AT+3V3T=(aa bb)
1093 +**07 02 aa bb**  Same as AT+3V3T=(aa bb)
1074 1074  
1075 1075  
1076 1076  
1654133913295-597.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +116.2 KB
Content
1654133954153-643.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +91.2 KB
Content
1654134704555-320.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +91.4 KB
Content