Changes for page RS485-BL – Waterproof RS485 to LoRaWAN Converter
Last modified by Xiaoling on 2025/04/23 15:57
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 2 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -895,9 +895,9 @@ 895 895 (% style="color:#037691" %)**AF 03 02 06 **(% style="color:orange" %)**0B**(% style="color:red" %)** 02 **(% style="color:green" %)**05 07 08 0A **(% style="color:#037691" %)**00**(%%): Same as AT+DATACUT3=(% style="color:orange" %)**11**(%%),(% style="color:red" %)**2**(%%),(% style="color:green" %)**5~~7+8~~10** 896 896 897 897 898 -0xAB downlink command can be used for set AT+SEARCHx 898 +**0xAB** downlink command can be used for set AT+SEARCHx 899 899 900 -Example: **AB aa 01 03 xx xx xx** (03 here means there are total 3 bytes after 03) So 900 +**Example:** **AB aa 01 03 xx xx xx** (03 here means there are total 3 bytes after 03) So 901 901 902 902 * AB aa 01 03 xx xx xx same as AT+SEARCHaa=1,xx xx xx 903 903 * AB aa 02 03 xx xx xx 02 yy yy(03 means there are 3 bytes after 03, they are xx xx xx;02 means there are 2 bytes after 02, they are yy yy) so the commands ... ... @@ -905,87 +905,100 @@ 905 905 **AB aa 02 03 xx xx xx 02 yy yy** same as **AT+SEARCHaa=2,xx xx xx+yy yy** 906 906 907 907 908 -==== Fast command to handle MODBUS device ==== 909 909 909 +==== **Fast command to handle MODBUS device** ==== 910 + 910 910 AT+MBFUN is valid since v1.3 firmware version. The command is for fast configure to read Modbus devices. It is only valid for the devices which follow the [[MODBUS-RTU protocol>>url:https://www.modbustools.com/modbus.html]]. 911 911 912 912 This command is valid since v1.3 firmware version 913 913 914 914 915 -AT+MBFUN has only two value: 916 +**AT+MBFUN has only two value:** 916 916 917 -* AT+MBFUN=1: Enable Modbus reading. And get response base on the MODBUS return 918 +* **AT+MBFUN=1**: Enable Modbus reading. And get response base on the MODBUS return 918 918 919 919 AT+MBFUN=1, device can auto read the Modbus function code: 01, 02, 03 or 04. AT+MBFUN has lower priority vs AT+DATACUT command. If AT+DATACUT command is configured, AT+MBFUN will be ignore. 920 920 921 -* AT+MBFUN=0: Disable Modbus fast reading. 922 +* **AT+MBFUN=0**: Disable Modbus fast reading. 922 922 923 -Example: 924 +**Example:** 924 924 925 925 * AT+MBFUN=1 and AT+DATACUT1/AT+DATACUT2 are not configure (0,0,0). 926 926 * AT+COMMAND1= 01 03 00 10 00 08,1 ~-~-> read slave address 01 , function code 03, start address 00 01, quantity of registers 00 08. 927 927 * AT+COMMAND2= 01 02 00 40 00 10,1 ~-~-> read slave address 01 , function code 02, start address 00 40, quantity of inputs 00 10. 928 928 929 -[[image: file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image025.png]]930 +[[image:1654133913295-597.png]] 930 930 931 931 932 -[[image: file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image026.png]]933 +[[image:1654133954153-643.png]] 933 933 934 934 935 -* Downlink Commands: 936 +* **Downlink Commands:** 936 936 937 -A9 aa - àSame as AT+MBFUN=aa938 +**A9 aa** ~-~-> Same as AT+MBFUN=aa 938 938 939 939 940 -==== RS485 command timeout ==== 941 941 942 +==== **RS485 command timeout** ==== 943 + 942 942 Some Modbus device has slow action to send replies. This command is used to configure the RS485-BL to use longer time to wait for their action. 943 943 944 944 Default value: 0, range: 0 ~~ 5 seconds 945 945 946 946 947 -* AT Command: 949 +* **AT Command:** 948 948 949 -AT+CMDDLaa=hex(bb cc) 951 +(% class="box infomessage" %) 952 +((( 953 +**AT+CMDDLaa=hex(bb cc)** 954 +))) 950 950 951 -Example: 956 +**Example:** 952 952 953 953 **AT+CMDDL1=1000** to send the open time to 1000ms 954 954 955 955 956 -* Downlink Payload: 961 +* **Downlink Payload:** 957 957 958 958 0x AA aa bb cc 959 959 960 960 Same as: AT+CMDDLaa=hex(bb cc) 961 961 962 - Example: 967 + **Example:** 963 963 964 - 0xAA 01 03 E8 àSame as **AT+CMDDL1=1000 ms**969 + **0xAA 01 03 E8** ~-~-> Same as **AT+CMDDL1=1000 ms** 965 965 966 966 967 -==== [[Uplink>>path:#downlink_A8]] payload mode ==== 968 968 973 +==== **Uplink payload mode** ==== 974 + 969 969 Define to use one uplink or multiple uplinks for the sampling. 970 970 971 -The use of this command please see: [[Compose Uplink payload>> path:#DataUP]]977 +The use of this command please see: [[Compose Uplink payload>>||anchor="H3.3.4Composetheuplinkpayload"]] 972 972 973 -* AT Command: 979 +* **AT Command:** 974 974 975 -AT+DATAUP=0 981 +(% class="box infomessage" %) 982 +((( 983 +**AT+DATAUP=0** 984 +))) 976 976 977 -AT+DATAUP=1 986 +(% class="box infomessage" %) 987 +((( 988 +**AT+DATAUP=1** 989 +))) 978 978 979 979 980 -* Downlink Payload: 992 +* **Downlink Payload:** 981 981 982 -0xAD 00 àSame as AT+DATAUP=0994 +**0xAD 00** **~-~->** Same as AT+DATAUP=0 983 983 984 -0xAD 01 àSame as AT+DATAUP=1996 +**0xAD 01** **~-~->** Same as AT+DATAUP=1 985 985 986 986 987 -==== Manually trigger an Uplink ==== 988 988 1000 +==== **Manually trigger an Uplink** ==== 1001 + 989 989 Ask device to send an uplink immediately. 990 990 991 991 * Downlink Payload: ... ... @@ -1075,13 +1075,13 @@ 1075 1075 1076 1076 1077 1077 1078 -1. 1091 +1. 1079 1079 11. Buttons 1080 1080 1081 1081 |**Button**|**Feature** 1082 1082 |**RST**|Reboot RS485-BL 1083 1083 1084 -1. 1097 +1. 1085 1085 11. +3V3 Output 1086 1086 1087 1087 RS485-BL has a Controllable +3V3 output, user can use this output to power external sensor. ... ... @@ -1099,7 +1099,7 @@ 1099 1099 By default, the AT+3V3T=0. This is a special case, means the +3V3 output is always on at any time 1100 1100 1101 1101 1102 -1. 1115 +1. 1103 1103 11. +5V Output 1104 1104 1105 1105 RS485-BL has a Controllable +5V output, user can use this output to power external sensor. ... ... @@ -1119,13 +1119,13 @@ 1119 1119 1120 1120 1121 1121 1122 -1. 1135 +1. 1123 1123 11. LEDs 1124 1124 1125 1125 |**LEDs**|**Feature** 1126 1126 |**LED1**|Blink when device transmit a packet. 1127 1127 1128 -1. 1141 +1. 1129 1129 11. Switch Jumper 1130 1130 1131 1131 |**Switch Jumper**|**Feature** ... ... @@ -1171,7 +1171,7 @@ 1171 1171 1172 1172 1173 1173 1174 -1. 1187 +1. 1175 1175 11. Common AT Command Sequence 1176 1176 111. Multi-channel ABP mode (Use with SX1301/LG308) 1177 1177 ... ... @@ -1190,8 +1190,8 @@ 1190 1190 1191 1191 ATZ 1192 1192 1193 -1. 1194 -11. 1206 +1. 1207 +11. 1195 1195 111. Single-channel ABP mode (Use with LG01/LG02) 1196 1196 1197 1197 AT+FDR Reset Parameters to Factory Default, Keys Reserve ... ... @@ -1266,7 +1266,7 @@ 1266 1266 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image035.png]] [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image036.png]] 1267 1267 1268 1268 1269 -1. 1282 +1. 1270 1270 11. How to change the LoRa Frequency Bands/Region? 1271 1271 1272 1272 User can follow the introduction for [[how to upgrade image>>path:#upgrade_image]]. When download the images, choose the required image file for download. ... ... @@ -1273,7 +1273,7 @@ 1273 1273 1274 1274 1275 1275 1276 -1. 1289 +1. 1277 1277 11. How many RS485-Slave can RS485-BL connects? 1278 1278 1279 1279 The RS485-BL can support max 32 RS485 devices. Each uplink command of RS485-BL can support max 16 different RS485 command. So RS485-BL can support max 16 RS485 devices pre-program in the device for uplink. For other devices no pre-program, user can use the [[downlink message (type code 0xA8) to poll their info>>path:#downlink_A8]]. ... ... @@ -1290,7 +1290,7 @@ 1290 1290 1291 1291 1292 1292 1293 -1. 1306 +1. 1294 1294 11. Why I can’t join TTN V3 in US915 /AU915 bands? 1295 1295 1296 1296 It might about the channels mapping. Please see for detail.
- 1654133913295-597.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +116.2 KB - Content
- 1654133954153-643.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +91.2 KB - Content