... ... @@ -895,9 +895,9 @@
895 895  (% style="color:#037691" %)**AF 03 02 06 **(% style="color:orange" %)**0B**(% style="color:red" %)** 02 **(% style="color:green" %)**05 07 08 0A **(% style="color:#037691" %)**00**(%%): Same as AT+DATACUT3=(% style="color:orange" %)**11**(%%),(% style="color:red" %)**2**(%%),(% style="color:green" %)**5~~7+8~~10**
896 896  
897 897  
898 -0xAB downlink command can be used for set AT+SEARCHx
898 +**0xAB** downlink command can be used for set AT+SEARCHx
899 899  
900 -Example: **AB aa 01 03 xx xx xx** (03 here means there are total 3 bytes after 03) So
900 +**Example:** **AB aa 01 03 xx xx xx** (03 here means there are total 3 bytes after 03) So
901 901  
902 902  * AB aa 01 03 xx xx xx  same as AT+SEARCHaa=1,xx xx xx
903 903  * AB aa 02 03 xx xx xx 02 yy yy(03 means there are 3 bytes after 03, they are xx xx xx;02 means there are 2 bytes after 02, they are yy yy) so the commands
... ... @@ -905,83 +905,95 @@
905 905  **AB aa 02 03 xx xx xx 02 yy yy**  same as **AT+SEARCHaa=2,xx xx xx+yy yy**
906 906  
907 907  
908 -==== Fast command to handle MODBUS device ====
909 909  
909 +==== **Fast command to handle MODBUS device** ====
910 +
910 910  AT+MBFUN is valid since v1.3 firmware version. The command is for fast configure to read Modbus devices. It is only valid for the devices which follow the [[MODBUS-RTU protocol>>url:https://www.modbustools.com/modbus.html]].
911 911  
912 912  This command is valid since v1.3 firmware version
913 913  
914 914  
915 -AT+MBFUN has only two value:
916 +**AT+MBFUN has only two value:**
916 916  
917 -* AT+MBFUN=1: Enable Modbus reading. And get response base on the MODBUS return
918 +* **AT+MBFUN=1**: Enable Modbus reading. And get response base on the MODBUS return
918 918  
919 919  AT+MBFUN=1, device can auto read the Modbus function code: 01, 02, 03 or 04. AT+MBFUN has lower priority vs AT+DATACUT command. If AT+DATACUT command is configured, AT+MBFUN will be ignore.
920 920  
921 -* AT+MBFUN=0: Disable Modbus fast reading.
922 +* **AT+MBFUN=0**: Disable Modbus fast reading.
922 922  
923 -Example:
924 +**Example:**
924 924  
925 925  * AT+MBFUN=1 and AT+DATACUT1/AT+DATACUT2 are not configure (0,0,0).
926 926  * AT+COMMAND1= 01 03 00 10 00 08,1 ~-~-> read slave address 01 , function code 03, start address 00 01, quantity of registers 00 08.
927 927  * AT+COMMAND2= 01 02 00 40 00 10,1 ~-~-> read slave address 01 , function code 02, start address 00 40, quantity of inputs 00 10.
928 928  
929 -[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image025.png]]
930 +[[image:1654133913295-597.png]]
930 930  
931 931  
932 -[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image026.png]]
933 +[[image:1654133954153-643.png]]
933 933  
934 934  
935 -* Downlink Commands:
936 +* **Downlink Commands:**
936 936  
937 -A9 aa -à Same as AT+MBFUN=aa
938 +**A9 aa** ~-~-> Same as AT+MBFUN=aa
938 938  
939 939  
940 -==== RS485 command timeout ====
941 941  
942 +==== **RS485 command timeout** ====
943 +
942 942  Some Modbus device has slow action to send replies. This command is used to configure the RS485-BL to use longer time to wait for their action.
943 943  
944 944  Default value: 0, range:  0 ~~ 5 seconds
945 945  
946 946  
947 -* AT Command:
949 +* **AT Command:**
948 948  
949 -AT+CMDDLaa=hex(bb cc)
951 +(% class="box infomessage" %)
952 +(((
953 +**AT+CMDDLaa=hex(bb cc)**
954 +)))
950 950  
951 -Example:
956 +**Example:**
952 952  
953 953  **AT+CMDDL1=1000** to send the open time to 1000ms
954 954  
955 955  
956 -* Downlink Payload:
961 +* **Downlink Payload:**
957 957  
958 958  0x AA aa bb cc
959 959  
960 960  Same as: AT+CMDDLaa=hex(bb cc)
961 961  
962 - Example:
967 + **Example:**
963 963  
964 - 0xAA 01 03 E8  à Same as **AT+CMDDL1=1000 ms**
969 + **0xAA 01 03 E8**  ~-~-> Same as **AT+CMDDL1=1000 ms**
965 965  
966 966  
967 -==== [[Uplink>>path:#downlink_A8]] payload mode ====
968 968  
973 +==== **Uplink payload mode** ====
974 +
969 969  Define to use one uplink or multiple uplinks for the sampling.
970 970  
971 -The use of this command please see: [[Compose Uplink payload>>path:#DataUP]]
977 +The use of this command please see: [[Compose Uplink payload>>||anchor="H3.3.4Composetheuplinkpayload"]]
972 972  
973 -* AT Command:
979 +* **AT Command:**
974 974  
975 -AT+DATAUP=0
981 +(% class="box infomessage" %)
982 +(((
983 +**AT+DATAUP=0**
984 +)))
976 976  
977 -AT+DATAUP=1
986 +(% class="box infomessage" %)
987 +(((
988 +**AT+DATAUP=1**
989 +)))
978 978  
979 979  
980 -* Downlink Payload:
992 +* **Downlink Payload:**
981 981  
982 -0xAD 00   à Same as AT+DATAUP=0
994 +0xAD 00  **~-~->** Same as AT+DATAUP=0
983 983  
984 -0xAD 01   à Same as AT+DATAUP=1
996 +0xAD 01  **~-~->** Same as AT+DATAUP=1
985 985  
986 986  
987 987  ==== Manually trigger an Uplink ====
... ... @@ -1075,13 +1075,13 @@
1075 1075  
1076 1076  
1077 1077  
1078 -1.
1090 +1.
1079 1079  11. Buttons
1080 1080  
1081 1081  |**Button**|**Feature**
1082 1082  |**RST**|Reboot RS485-BL
1083 1083  
1084 -1.
1096 +1.
1085 1085  11. +3V3 Output
1086 1086  
1087 1087  RS485-BL has a Controllable +3V3 output, user can use this output to power external sensor.
... ... @@ -1099,7 +1099,7 @@
1099 1099  By default, the AT+3V3T=0. This is a special case, means the +3V3 output is always on at any time
1100 1100  
1101 1101  
1102 -1.
1114 +1.
1103 1103  11. +5V Output
1104 1104  
1105 1105  RS485-BL has a Controllable +5V output, user can use this output to power external sensor.
... ... @@ -1119,13 +1119,13 @@
1119 1119  
1120 1120  
1121 1121  
1122 -1.
1134 +1.
1123 1123  11. LEDs
1124 1124  
1125 1125  |**LEDs**|**Feature**
1126 1126  |**LED1**|Blink when device transmit a packet.
1127 1127  
1128 -1.
1140 +1.
1129 1129  11. Switch Jumper
1130 1130  
1131 1131  |**Switch Jumper**|**Feature**
... ... @@ -1171,7 +1171,7 @@
1171 1171  
1172 1172  
1173 1173  
1174 -1.
1186 +1.
1175 1175  11. Common AT Command Sequence
1176 1176  111. Multi-channel ABP mode (Use with SX1301/LG308)
1177 1177  
... ... @@ -1190,8 +1190,8 @@
1190 1190  
1191 1191  ATZ
1192 1192  
1193 -1.
1194 -11.
1205 +1.
1206 +11.
1195 1195  111. Single-channel ABP mode (Use with LG01/LG02)
1196 1196  
1197 1197  AT+FDR   Reset Parameters to Factory Default, Keys Reserve
... ... @@ -1266,7 +1266,7 @@
1266 1266  [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image035.png]] [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image036.png]]
1267 1267  
1268 1268  
1269 -1.
1281 +1.
1270 1270  11. How to change the LoRa Frequency Bands/Region?
1271 1271  
1272 1272  User can follow the introduction for [[how to upgrade image>>path:#upgrade_image]]. When download the images, choose the required image file for download.
... ... @@ -1273,7 +1273,7 @@
1273 1273  
1274 1274  
1275 1275  
1276 -1.
1288 +1.
1277 1277  11. How many RS485-Slave can RS485-BL connects?
1278 1278  
1279 1279  The RS485-BL can support max 32 RS485 devices. Each uplink command of RS485-BL can support max 16 different RS485 command. So RS485-BL can support max 16 RS485 devices pre-program in the device for uplink. For other devices no pre-program, user can use the [[downlink message (type code 0xA8) to poll their info>>path:#downlink_A8]].
... ... @@ -1290,7 +1290,7 @@
1290 1290  
1291 1291  
1292 1292  
1293 -1.
1305 +1.
1294 1294  11. Why I can’t join TTN V3 in US915 /AU915 bands?
1295 1295  
1296 1296  It might about the channels mapping. Please see for detail.
1654133913295-597.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +116.2 KB
Content
1654133954153-643.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +91.2 KB
Content