Changes for page RS485-BL – Waterproof RS485 to LoRaWAN Converter
Last modified by Xiaoling on 2025/04/23 15:57
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 1 removed)
Details
- Page properties
-
- Content
-
... ... @@ -316,6 +316,7 @@ 316 316 ))) 317 317 ))) 318 318 319 + 319 319 === 3.3.2 Configure sensors === 320 320 321 321 ((( ... ... @@ -436,7 +436,7 @@ 436 436 437 437 **Examples:** 438 438 439 -1 )For a return string from AT+COMMAND1: 16 0c 1e 56 34 2e 30 58 5f 36 41 30 31 00 49440 +1. For a return string from AT+COMMAND1: 16 0c 1e 56 34 2e 30 58 5f 36 41 30 31 00 49 440 440 441 441 If we set AT+SEARCH1=1,1E 56 34. (max 5 bytes for prefix) 442 442 ... ... @@ -444,7 +444,7 @@ 444 444 445 445 [[image:1653271044481-711.png]] 446 446 447 - 2)For a return string from AT+COMMAND1: 16 0c 1e 56 34 2e 30 58 5f 36 41 30 31 00 49448 +1. For a return string from AT+COMMAND1: 16 0c 1e 56 34 2e 30 58 5f 36 41 30 31 00 49 448 448 449 449 If we set AT+SEARCH1=2, 1E 56 34+31 00 49 450 450 ... ... @@ -463,18 +463,16 @@ 463 463 * **c: define the position for valid value. ** 464 464 ))) 465 465 466 - **Examples:**467 +Examples: 467 467 468 468 * Grab bytes: 469 469 470 470 [[image:1653271581490-837.png||height="313" width="722"]] 471 471 472 - 473 473 * Grab a section. 474 474 475 475 [[image:1653271648378-342.png||height="326" width="720"]] 476 476 477 - 478 478 * Grab different sections. 479 479 480 480 [[image:1653271657255-576.png||height="305" width="730"]] ... ... @@ -517,7 +517,6 @@ 517 517 518 518 [[image:1653271763403-806.png]] 519 519 520 - 521 521 === 3.3.4 Compose the uplink payload === 522 522 523 523 ((( ... ... @@ -525,7 +525,7 @@ 525 525 ))) 526 526 527 527 ((( 528 -(% style="color:# 037691" %)**Examples: AT+DATAUP=0**526 +(% style="color:#4f81bd" %)**Examples: AT+DATAUP=0** 529 529 ))) 530 530 531 531 ((( ... ... @@ -537,7 +537,7 @@ 537 537 ))) 538 538 539 539 ((( 540 -(% style="color:#4f81bd" %) **Battery Info+PAYVER + VALID Value from RETURN1 + Valid Value from RETURN2 + … + RETURNx**538 +(% style="color:#4f81bd" %)Battery Info+PAYVER + VALID Value from RETURN1 + Valid Value from RETURN2 + … + RETURNx 541 541 ))) 542 542 543 543 ((( ... ... @@ -546,12 +546,8 @@ 546 546 547 547 [[image:1653272787040-634.png||height="515" width="719"]] 548 548 549 - 550 - 551 551 ((( 552 -(% style="color:#037691" %)**Examples: AT+DATAUP=1** 553 - 554 - 548 +(% style="color:#4f81bd" %)**Examples: AT+DATAUP=1** 555 555 ))) 556 556 557 557 ((( ... ... @@ -563,7 +563,7 @@ 563 563 ))) 564 564 565 565 ((( 566 -(% style="color:#4f81bd" %) **Battery Info+PAYVER + PAYLOAD COUNT + PAYLOAD# + DATA**560 +(% style="color:#4f81bd" %)Battery Info+PAYVER + PAYLOAD COUNT + PAYLOAD# + DATA 567 567 ))) 568 568 569 569 1. ((( ... ... @@ -586,7 +586,6 @@ 586 586 587 587 So totally there will be 3 uplinks for this sampling, each uplink includes 6 bytes DATA 588 588 589 - 590 590 DATA1=RETURN1 Valid Value = (% style="background-color:#4f81bd; color:white" %) 20 20 0a 33 90 41 591 591 592 592 DATA2=1^^st^^ ~~ 6^^th^^ byte of Valid value of RETURN10= (% style="background-color:#4f81bd; color:white" %)02 aa 05 81 0a 20 ... ... @@ -593,12 +593,10 @@ 593 593 594 594 DATA3=7^^th^^ ~~ 11^^th^^ bytes of Valid value of RETURN10 =(% style="background-color:#4f81bd; color:white" %) 20 20 20 2d 30 595 595 596 - 597 597 Below are the uplink payloads: 598 598 599 599 [[image:1653272901032-107.png]] 600 600 601 - 602 602 (% style="color:red" %)Notice: the Max bytes is according to the max support bytes in different Frequency Bands for lowest SF. As below: 603 603 604 604 ~* For AU915/AS923 bands, if UplinkDwell time=0, max 51 bytes for each uplink ( so 51 -5 = 46 max valid date) ... ... @@ -609,8 +609,6 @@ 609 609 610 610 ~* For all other bands: max 51 bytes for each uplink ( so 51 -5 = 46 max valid date). 611 611 612 - 613 - 614 614 === 3.3.5 Uplink on demand === 615 615 616 616 ((( ... ... @@ -627,8 +627,6 @@ 627 627 628 628 ((( 629 629 **0xA8 command**: Send a command to RS485-BL and uplink the output from sensors. 630 - 631 - 632 632 ))) 633 633 634 634 === 3.3.6 Uplink on Interrupt === ... ... @@ -637,7 +637,6 @@ 637 637 638 638 [[image:1653273818896-432.png]] 639 639 640 - 641 641 ((( 642 642 AT+INTMOD=0 Disable Interrupt 643 643 ))) ... ... @@ -652,8 +652,6 @@ 652 652 653 653 ((( 654 654 AT+INTMOD=3 Interrupt trigger by rising edge. 655 - 656 - 657 657 ))) 658 658 659 659 == 3.4 Uplink Payload == ... ... @@ -681,49 +681,47 @@ 681 681 Below is the decoder for the first 3 bytes. The rest bytes are dynamic depends on different RS485 sensors. 682 682 683 683 ((( 684 - {{{function Decoder(bytes, port) {}}}668 +function Decoder(bytes, port) { 685 685 ))) 686 686 687 687 ((( 688 - {{{//Payload Formats of RS485-BL Deceive}}}672 +~/~/Payload Formats of RS485-BL Deceive 689 689 ))) 690 690 691 691 ((( 692 - {{{return {}}}676 +return { 693 693 ))) 694 694 695 695 ((( 696 - {{{//Battery,units:V}}}680 + ~/~/Battery,units:V 697 697 ))) 698 698 699 699 ((( 700 - {{{BatV:((bytes[0]<<8 | bytes[1])&0x7fff)/1000,}}}684 + BatV:((bytes[0]<<8 | bytes[1])&0x7fff)/1000, 701 701 ))) 702 702 703 703 ((( 704 - {{{//GPIO_EXTI}}}688 + ~/~/GPIO_EXTI 705 705 ))) 706 706 707 707 ((( 708 - {{{EXTI_Trigger:(bytes[0] & 0x80)? "TRUE":"FALSE",}}}692 + EXTI_Trigger:(bytes[0] & 0x80)? "TRUE":"FALSE", 709 709 ))) 710 710 711 711 ((( 712 - {{{//payload of version}}}696 + ~/~/payload of version 713 713 ))) 714 714 715 715 ((( 716 - {{{Pay_ver:bytes[2],}}}700 + Pay_ver:bytes[2], 717 717 ))) 718 718 719 719 ((( 720 - {{{};}}}704 + }; 721 721 ))) 722 722 723 723 ((( 724 -} 725 - 726 - 708 + } 727 727 ))) 728 728 729 729 ((( ... ... @@ -732,66 +732,58 @@ 732 732 733 733 [[image:1653274001211-372.png||height="192" width="732"]] 734 734 735 - 736 736 == 3.5 Configure RS485-BL via AT or Downlink == 737 737 738 -User can configure RS485-BL via AT Commands 719 +User can configure RS485-BL via [[AT Commands >>path:#_Using_the_AT]]or LoRaWAN Downlink Commands 739 739 740 740 There are two kinds of Commands: 741 741 742 -* (% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports:[[End Device AT Commandsand Downlink Command>>doc:Main.End.WebHome]]723 +* **Common Commands**: They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: http:~/~/wiki.dragino.com/index.php?title=End_Device_AT_Commands_and_Downlink_Commands 743 743 744 -* (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for RS485-BL. User can see these commands below:725 +* **Sensor Related Commands**: These commands are special designed for RS485-BL. User can see these commands below: 745 745 727 +1. 728 +11. 729 +111. Common Commands: 746 746 747 - ===3.5.1CommonCommands: ===731 +They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[http:~~/~~/wiki.dragino.com/index.php?title=End_Device_AT_Commands_and_Downlink_Commands>>url:http://wiki.dragino.com/index.php?title=End_Device_AT_Commands_and_Downlink_Commands]] 748 748 749 -They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] 750 750 734 +1. 735 +11. 736 +111. Sensor related commands: 751 751 752 -=== 3.5.2 Sensorrelatedcommands:===738 +==== Choose Device Type (RS485 or TTL) ==== 753 753 754 -==== ==== 755 - 756 -==== **Choose Device Type (RS485 or TTL)** ==== 757 - 758 758 RS485-BL can connect to either RS485 sensors or TTL sensor. User need to specify what type of sensor need to connect. 759 759 760 -* **AT Command**742 +* AT Command 761 761 762 -(% class="box infomessage" %) 763 -((( 764 764 **AT+MOD=1** ~/~/ Set to support RS485-MODBUS type sensors. User can connect multiply RS485 , Modbus sensors to the A / B pins. 765 -))) 766 766 767 -(% class="box infomessage" %) 768 -((( 769 769 **AT+MOD=2** ~/~/ Set to support TTL Level sensors, User can connect one TTL Sensor to the TXD/RXD/GND pins. 770 -))) 771 771 772 772 773 -* **Downlink Payload**749 +* Downlink Payload 774 774 775 -**0A aa** ~-~->same as AT+MOD=aa751 +**0A aa** à same as AT+MOD=aa 776 776 777 777 778 778 779 -==== **RS485 Debug Command (AT+CFGDEV)**====755 +==== [[RS485 Debug Command>>path:#downlink_A8]] (AT+CFGDEV) ==== 780 780 781 781 This command is used to configure the RS485 or TTL sensors; they won’t be used during sampling. 782 782 783 -* **AT Command**759 +* AT Command 784 784 785 -(% class="box infomessage" %) 786 -((( 787 -**AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m** 788 -))) 761 +AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m 789 789 790 790 m: 0: no CRC; 1: add CRC-16/MODBUS in the end of this command. 791 791 792 792 793 -* **Downlink Payload** 794 794 767 +* Downlink Payload 768 + 795 795 Format: A8 MM NN XX XX XX XX YY 796 796 797 797 Where: ... ... @@ -805,15 +805,15 @@ 805 805 806 806 To connect a Modbus Alarm with below commands. 807 807 808 -* The command to active alarm is: 0A 05 00 04 00 01 **4C B0**. Where 0A 05 00 04 00 01 is the Modbus command to read the register 00 40 where stored the DI status. The 4C B0 is the CRC-16/MODBUS which calculate manually.782 +* The command to active alarm is: 0A 05 00 04 00 01 4C B0. Where 0A 05 00 04 00 01 is the Modbus command to read the register 00 40 where stored the DI status. The 4C B0 is the CRC-16/MODBUS which calculate manually. 809 809 810 -* The command to deactivate alarm is: 0A 05 00 04 00 00 **8D 70**. Where 0A 05 00 04 00 00 is the Modbus command to read the register 00 40 where stored the DI status. The 8D 70 is the CRC-16/MODBUS which calculate manually.784 +* The command to deactivate alarm is: 0A 05 00 04 00 00 8D 70. Where 0A 05 00 04 00 00 is the Modbus command to read the register 00 40 where stored the DI status. The 8D 70 is the CRC-16/MODBUS which calculate manually. 811 811 812 812 So if user want to use downlink command to control to RS485 Alarm, he can use: 813 813 814 - (% style="color:#037691" %)**A8 01 06 0A 05 00 04 00 01 00**(%%): to activate the RS485 Alarm788 +**A8 01 06 0A 05 00 04 00 01 00**: to activate the RS485 Alarm 815 815 816 - (% style="color:#037691" %)**A8 01 06 0A 05 00 04 00 00 00**(%%): to deactivate the RS485 Alarm790 +**A8 01 06 0A 05 00 04 00 00 00**: to deactivate the RS485 Alarm 817 817 818 818 A8 is type code and 01 means add CRC-16/MODBUS at the end, the 3^^rd^^ byte is 06, means the next 6 bytes are the command to be sent to the RS485 network, the final byte 00 means this command don’t need to acquire output. 819 819 ... ... @@ -822,35 +822,32 @@ 822 822 823 823 Check TTL Sensor return: 824 824 825 -[[image: 1654132684752-193.png]]799 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image024.png]] 826 826 827 827 828 828 829 -==== **Set Payload version** ==== 830 830 804 +==== Set Payload version ==== 805 + 831 831 This is the first byte of the uplink payload. RS485-BL can connect to different sensors. User can set the PAYVER field to tell server how to decode the current payload. 832 832 833 -* **AT Command:**808 +* AT Command: 834 834 835 -(% class="box infomessage" %) 836 -((( 837 -**AT+PAYVER: Set PAYVER field = 1** 838 -))) 810 +AT+PAYVER: Set PAYVER field = 1 839 839 840 840 841 -* **Downlink Payload:**813 +* Downlink Payload: 842 842 843 - **0xAE 01**~-~->Set PAYVER field = 0x01815 +0xAE 01 à Set PAYVER field = 0x01 844 844 845 - **0xAE 0F**~-~->Set PAYVER field = 0x0F817 +0xAE 0F à Set PAYVER field = 0x0F 846 846 847 847 820 +==== Set RS485 Sampling Commands ==== 848 848 849 -==== **Set RS485 Sampling Commands** ==== 850 - 851 851 AT+COMMANDx, AT+DATACUTx and AT+SEARCHx 852 852 853 -These three commands are used to configure how the RS485-BL polling data from Modbus device. Detail of usage please see : [[polling RS485 device>> ||anchor="H3.3.3Configurereadcommandsforeachsampling"]].824 +These three commands are used to configure how the RS485-BL polling data from Modbus device. Detail of usage please see : [[polling RS485 device>>path:#polling_485]]. 854 854 855 855 856 856 * AT Command: ... ... @@ -1067,13 +1067,13 @@ 1067 1067 1068 1068 1069 1069 1070 -1. 1041 +1. 1071 1071 11. Buttons 1072 1072 1073 1073 |**Button**|**Feature** 1074 1074 |**RST**|Reboot RS485-BL 1075 1075 1076 -1. 1047 +1. 1077 1077 11. +3V3 Output 1078 1078 1079 1079 RS485-BL has a Controllable +3V3 output, user can use this output to power external sensor. ... ... @@ -1091,7 +1091,7 @@ 1091 1091 By default, the AT+3V3T=0. This is a special case, means the +3V3 output is always on at any time 1092 1092 1093 1093 1094 -1. 1065 +1. 1095 1095 11. +5V Output 1096 1096 1097 1097 RS485-BL has a Controllable +5V output, user can use this output to power external sensor. ... ... @@ -1111,13 +1111,13 @@ 1111 1111 1112 1112 1113 1113 1114 -1. 1085 +1. 1115 1115 11. LEDs 1116 1116 1117 1117 |**LEDs**|**Feature** 1118 1118 |**LED1**|Blink when device transmit a packet. 1119 1119 1120 -1. 1091 +1. 1121 1121 11. Switch Jumper 1122 1122 1123 1123 |**Switch Jumper**|**Feature** ... ... @@ -1163,7 +1163,7 @@ 1163 1163 1164 1164 1165 1165 1166 -1. 1137 +1. 1167 1167 11. Common AT Command Sequence 1168 1168 111. Multi-channel ABP mode (Use with SX1301/LG308) 1169 1169 ... ... @@ -1182,8 +1182,8 @@ 1182 1182 1183 1183 ATZ 1184 1184 1185 -1. 1186 -11. 1156 +1. 1157 +11. 1187 1187 111. Single-channel ABP mode (Use with LG01/LG02) 1188 1188 1189 1189 AT+FDR Reset Parameters to Factory Default, Keys Reserve ... ... @@ -1258,7 +1258,7 @@ 1258 1258 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image035.png]] [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image036.png]] 1259 1259 1260 1260 1261 -1. 1232 +1. 1262 1262 11. How to change the LoRa Frequency Bands/Region? 1263 1263 1264 1264 User can follow the introduction for [[how to upgrade image>>path:#upgrade_image]]. When download the images, choose the required image file for download. ... ... @@ -1265,7 +1265,7 @@ 1265 1265 1266 1266 1267 1267 1268 -1. 1239 +1. 1269 1269 11. How many RS485-Slave can RS485-BL connects? 1270 1270 1271 1271 The RS485-BL can support max 32 RS485 devices. Each uplink command of RS485-BL can support max 16 different RS485 command. So RS485-BL can support max 16 RS485 devices pre-program in the device for uplink. For other devices no pre-program, user can use the [[downlink message (type code 0xA8) to poll their info>>path:#downlink_A8]]. ... ... @@ -1282,7 +1282,7 @@ 1282 1282 1283 1283 1284 1284 1285 -1. 1256 +1. 1286 1286 11. Why I can’t join TTN V3 in US915 /AU915 bands? 1287 1287 1288 1288 It might about the channels mapping. Please see for detail.
- 1654132684752-193.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -22.8 KB - Content