Changes for page RS485-BL – Waterproof RS485 to LoRaWAN Converter
Last modified by Xiaoling on 2025/04/23 15:57
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 2 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -743,8 +743,6 @@ 743 743 744 744 * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for RS485-BL. User can see these commands below: 745 745 746 - 747 - 748 748 === 3.5.1 Common Commands: === 749 749 750 750 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] ... ... @@ -802,7 +802,6 @@ 802 802 * XX XX XX XX: RS485 command total NN bytes 803 803 * YY: How many bytes will be uplink from the return of this RS485 command, if YY=0, RS485-BL will execute the downlink command without uplink; if YY>0, RS485-BL will uplink total YY bytes from the output of this RS485 command 804 804 805 - 806 806 **Example 1:** 807 807 808 808 To connect a Modbus Alarm with below commands. ... ... @@ -852,23 +852,32 @@ 852 852 853 853 AT+COMMANDx, AT+DATACUTx and AT+SEARCHx 854 854 855 -These three commands are used to configure how the RS485-BL polling data from Modbus device. Detail of usage please see : [[polling RS485 device>> path:#polling_485]].852 +These three commands are used to configure how the RS485-BL polling data from Modbus device. Detail of usage please see : [[polling RS485 device>>||anchor="H3.3.3Configurereadcommandsforeachsampling"]]. 856 856 857 857 858 -* AT Command: 855 +* **AT Command:** 859 859 860 -AT+COMMANDx: Configure RS485 read command to sensor. 857 +(% class="box infomessage" %) 858 +((( 859 +**AT+COMMANDx: Configure RS485 read command to sensor.** 860 +))) 861 861 862 -AT+DATACUTx: Configure how to handle return from RS485 devices. 862 +(% class="box infomessage" %) 863 +((( 864 +**AT+DATACUTx: Configure how to handle return from RS485 devices.** 865 +))) 863 863 864 -AT+SEARCHx: Configure search command 867 +(% class="box infomessage" %) 868 +((( 869 +**AT+SEARCHx: Configure search command** 870 +))) 865 865 866 866 867 -* Downlink Payload: 873 +* **Downlink Payload:** 868 868 869 -0xAF downlink command can be used to set AT+COMMANDx or AT+DATACUTx. 875 +**0xAF** downlink command can be used to set AT+COMMANDx or AT+DATACUTx. 870 870 871 -Note: if user use AT+COMMANDx to add a new command, he also need to send AT+DATACUTx downlink. 877 +(% style="color:red" %)**Note**(%%): if user use AT+COMMANDx to add a new command, he also need to send AT+DATACUTx downlink. 872 872 873 873 Format: AF MM NN LL XX XX XX XX YY 874 874 ... ... @@ -875,23 +875,23 @@ 875 875 Where: 876 876 877 877 * MM: the ATCOMMAND or AT+DATACUT to be set. Value from 01 ~~ 0F, 878 -* NN: 0: no CRC; 1: add CRC-16/MODBUS ; 2: set the AT+DATACUT value. 879 -* LL: The length of AT+COMMAND or AT+DATACUT command 884 +* NN: 0: no CRC; 1: add CRC-16/MODBUS ; 2: set the AT+DATACUT value. 885 +* LL: The length of AT+COMMAND or AT+DATACUT command 880 880 * XX XX XX XX: AT+COMMAND or AT+DATACUT command 881 -* YY: If YY=0, RS485-BL will execute the downlink command without uplink; if YY=1, RS485-BL will execute an uplink after got this command. 887 +* YY: If YY=0, RS485-BL will execute the downlink command without uplink; if YY=1, RS485-BL will execute an uplink after got this command. 882 882 883 -Example: 889 +**Example:** 884 884 885 -**AF 03 01 06 0A 05 00 04 00 01 00**: Same as AT+COMMAND3=0A 05 00 04 00 01,1 891 +(% style="color:#037691" %)**AF 03 01 06 0A 05 00 04 00 01 00**(%%): Same as AT+COMMAND3=0A 05 00 04 00 01,1 886 886 887 -**AF 03 02 06 10 01 05 06 09 0A 00**: Same as AT+DATACUT3=**16**,**1**,**5+6+9+10** 893 +(% style="color:#037691" %)**AF 03 02 06**(% style="color:orange" %)** 10 **(% style="color:red" %)**01 **(% style="color:green" %)**05 06 09 0A**(% style="color:#037691" %)** 00**(%%): Same as AT+DATACUT3=(% style="color:orange" %)**16**(%%),(% style="color:red" %)**1**(%%),(% style="color:green" %)**5+6+9+10** 888 888 889 -**AF 03 02 06 0B 02 05 07 08 0A 00**: Same as AT+DATACUT3=**11**,**2**,**5~~7+8~~10** 895 +(% style="color:#037691" %)**AF 03 02 06 **(% style="color:orange" %)**0B**(% style="color:red" %)** 02 **(% style="color:green" %)**05 07 08 0A **(% style="color:#037691" %)**00**(%%): Same as AT+DATACUT3=(% style="color:orange" %)**11**(%%),(% style="color:red" %)**2**(%%),(% style="color:green" %)**5~~7+8~~10** 890 890 891 891 892 -0xAB downlink command can be used for set AT+SEARCHx 898 +**0xAB** downlink command can be used for set AT+SEARCHx 893 893 894 -Example: **AB aa 01 03 xx xx xx** (03 here means there are total 3 bytes after 03) So 900 +**Example:** **AB aa 01 03 xx xx xx** (03 here means there are total 3 bytes after 03) So 895 895 896 896 * AB aa 01 03 xx xx xx same as AT+SEARCHaa=1,xx xx xx 897 897 * AB aa 02 03 xx xx xx 02 yy yy(03 means there are 3 bytes after 03, they are xx xx xx;02 means there are 2 bytes after 02, they are yy yy) so the commands ... ... @@ -899,67 +899,74 @@ 899 899 **AB aa 02 03 xx xx xx 02 yy yy** same as **AT+SEARCHaa=2,xx xx xx+yy yy** 900 900 901 901 902 -==== Fast command to handle MODBUS device ==== 903 903 909 +==== **Fast command to handle MODBUS device** ==== 910 + 904 904 AT+MBFUN is valid since v1.3 firmware version. The command is for fast configure to read Modbus devices. It is only valid for the devices which follow the [[MODBUS-RTU protocol>>url:https://www.modbustools.com/modbus.html]]. 905 905 906 906 This command is valid since v1.3 firmware version 907 907 908 908 909 -AT+MBFUN has only two value: 916 +**AT+MBFUN has only two value:** 910 910 911 -* AT+MBFUN=1: Enable Modbus reading. And get response base on the MODBUS return 918 +* **AT+MBFUN=1**: Enable Modbus reading. And get response base on the MODBUS return 912 912 913 913 AT+MBFUN=1, device can auto read the Modbus function code: 01, 02, 03 or 04. AT+MBFUN has lower priority vs AT+DATACUT command. If AT+DATACUT command is configured, AT+MBFUN will be ignore. 914 914 915 -* AT+MBFUN=0: Disable Modbus fast reading. 922 +* **AT+MBFUN=0**: Disable Modbus fast reading. 916 916 917 -Example: 918 918 925 +**Example:** 926 + 919 919 * AT+MBFUN=1 and AT+DATACUT1/AT+DATACUT2 are not configure (0,0,0). 920 920 * AT+COMMAND1= 01 03 00 10 00 08,1 ~-~-> read slave address 01 , function code 03, start address 00 01, quantity of registers 00 08. 921 921 * AT+COMMAND2= 01 02 00 40 00 10,1 ~-~-> read slave address 01 , function code 02, start address 00 40, quantity of inputs 00 10. 922 922 923 -[[image: file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image025.png]]931 +[[image:1654133913295-597.png]] 924 924 925 925 926 -[[image: file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image026.png]]934 +[[image:1654133954153-643.png]] 927 927 928 928 929 -* Downlink Commands: 937 +* **Downlink Commands:** 930 930 931 -A9 aa - àSame as AT+MBFUN=aa939 +**A9 aa** ~-~-> Same as AT+MBFUN=aa 932 932 933 933 934 -==== RS485 command timeout ==== 935 935 943 +==== **RS485 command timeout** ==== 944 + 936 936 Some Modbus device has slow action to send replies. This command is used to configure the RS485-BL to use longer time to wait for their action. 937 937 938 938 Default value: 0, range: 0 ~~ 5 seconds 939 939 940 940 941 -* AT Command: 950 +* **AT Command:** 942 942 943 -AT+CMDDLaa=hex(bb cc) 952 +(% class="box infomessage" %) 953 +((( 954 +**AT+CMDDLaa=hex(bb cc)** 955 +))) 944 944 945 -Example: 957 +**Example:** 946 946 947 947 **AT+CMDDL1=1000** to send the open time to 1000ms 948 948 949 949 950 -* Downlink Payload: 962 +* **Downlink Payload:** 951 951 952 952 0x AA aa bb cc 953 953 954 954 Same as: AT+CMDDLaa=hex(bb cc) 955 955 956 - Example: 968 + **Example:** 957 957 958 - 0xAA 01 03 E8 àSame as **AT+CMDDL1=1000 ms**970 + **0xAA 01 03 E8** ~-~-> Same as **AT+CMDDL1=1000 ms** 959 959 960 960 961 -==== [[Uplink>>path:#downlink_A8]] payload mode ==== 962 962 974 +==== **Uplink payload mode** ==== 975 + 963 963 Define to use one uplink or multiple uplinks for the sampling. 964 964 965 965 The use of this command please see: [[Compose Uplink payload>>path:#DataUP]]
- 1654133913295-597.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +116.2 KB - Content
- 1654133954153-643.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +91.2 KB - Content