... ... @@ -743,8 +743,6 @@
743 743  
744 744  * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for RS485-BL.  User can see these commands below:
745 745  
746 -
747 -
748 748  === 3.5.1 Common Commands: ===
749 749  
750 750  They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
... ... @@ -802,7 +802,6 @@
802 802  * XX XX XX XX: RS485 command total NN bytes
803 803  * YY: How many bytes will be uplink from the return of this RS485 command, if YY=0, RS485-BL will execute the downlink command without uplink; if YY>0, RS485-BL will uplink total YY bytes from the output of this RS485 command
804 804  
805 -
806 806  **Example 1:**
807 807  
808 808  To connect a Modbus Alarm with below commands.
... ... @@ -852,23 +852,32 @@
852 852  
853 853  AT+COMMANDx, AT+DATACUTx and AT+SEARCHx
854 854  
855 -These three commands are used to configure how the RS485-BL polling data from Modbus device. Detail of usage please see : [[polling RS485 device>>path:#polling_485]].
852 +These three commands are used to configure how the RS485-BL polling data from Modbus device. Detail of usage please see : [[polling RS485 device>>||anchor="H3.3.3Configurereadcommandsforeachsampling"]].
856 856  
857 857  
858 -* AT Command:
855 +* **AT Command:**
859 859  
860 -AT+COMMANDx: Configure RS485 read command to sensor.
857 +(% class="box infomessage" %)
858 +(((
859 +**AT+COMMANDx: Configure RS485 read command to sensor.**
860 +)))
861 861  
862 -AT+DATACUTx: Configure how to handle return from RS485 devices.
862 +(% class="box infomessage" %)
863 +(((
864 +**AT+DATACUTx: Configure how to handle return from RS485 devices.**
865 +)))
863 863  
864 -AT+SEARCHx: Configure search command
867 +(% class="box infomessage" %)
868 +(((
869 +**AT+SEARCHx: Configure search command**
870 +)))
865 865  
866 866  
867 -* Downlink Payload:
873 +* **Downlink Payload:**
868 868  
869 -0xAF downlink command can be used to set AT+COMMANDx or AT+DATACUTx.
875 +**0xAF** downlink command can be used to set AT+COMMANDx or AT+DATACUTx.
870 870  
871 -Note: if user use AT+COMMANDx to add a new command, he also need to send AT+DATACUTx downlink.
877 +(% style="color:red" %)**Note**(%%): if user use AT+COMMANDx to add a new command, he also need to send AT+DATACUTx downlink.
872 872  
873 873  Format: AF MM NN LL XX XX XX XX YY
874 874  
... ... @@ -875,23 +875,23 @@
875 875  Where:
876 876  
877 877  * MM: the ATCOMMAND or AT+DATACUT to be set. Value from 01 ~~ 0F,
878 -* NN: 0: no CRC; 1: add CRC-16/MODBUS ; 2: set the AT+DATACUT value.
879 -* LL: The length of AT+COMMAND or AT+DATACUT command
884 +* NN:  0: no CRC; 1: add CRC-16/MODBUS ; 2: set the AT+DATACUT value.
885 +* LL:  The length of AT+COMMAND or AT+DATACUT command
880 880  * XX XX XX XX: AT+COMMAND or AT+DATACUT command
881 -* YY: If YY=0, RS485-BL will execute the downlink command without uplink; if YY=1, RS485-BL will execute an uplink after got this command.
887 +* YY:  If YY=0, RS485-BL will execute the downlink command without uplink; if YY=1, RS485-BL will execute an uplink after got this command.
882 882  
883 -Example:
889 +**Example:**
884 884  
885 -**AF 03 01 06 0A 05 00 04 00 01 00**: Same as AT+COMMAND3=0A 05 00 04 00 01,1
891 +(% style="color:#037691" %)**AF 03 01 06 0A 05 00 04 00 01 00**(%%): Same as AT+COMMAND3=0A 05 00 04 00 01,1
886 886  
887 -**AF 03 02 06 10 01 05 06 09 0A 00**: Same as AT+DATACUT3=**16**,**1**,**5+6+9+10**
893 +(% style="color:#037691" %)**AF 03 02 06**(% style="color:orange" %)** 10 **(% style="color:red" %)**01 **(% style="color:green" %)**05 06 09 0A**(% style="color:#037691" %)** 00**(%%): Same as AT+DATACUT3=(% style="color:orange" %)**16**(%%),(% style="color:red" %)**1**(%%),(% style="color:green" %)**5+6+9+10**
888 888  
889 -**AF 03 02 06 0B 02 05 07 08 0A 00**: Same as AT+DATACUT3=**11**,**2**,**5~~7+8~~10**
895 +(% style="color:#037691" %)**AF 03 02 06 **(% style="color:orange" %)**0B**(% style="color:red" %)** 02 **(% style="color:green" %)**05 07 08 0A **(% style="color:#037691" %)**00**(%%): Same as AT+DATACUT3=(% style="color:orange" %)**11**(%%),(% style="color:red" %)**2**(%%),(% style="color:green" %)**5~~7+8~~10**
890 890  
891 891  
892 -0xAB downlink command can be used for set AT+SEARCHx
898 +**0xAB** downlink command can be used for set AT+SEARCHx
893 893  
894 -Example: **AB aa 01 03 xx xx xx** (03 here means there are total 3 bytes after 03) So
900 +**Example:** **AB aa 01 03 xx xx xx** (03 here means there are total 3 bytes after 03) So
895 895  
896 896  * AB aa 01 03 xx xx xx  same as AT+SEARCHaa=1,xx xx xx
897 897  * AB aa 02 03 xx xx xx 02 yy yy(03 means there are 3 bytes after 03, they are xx xx xx;02 means there are 2 bytes after 02, they are yy yy) so the commands
... ... @@ -899,6 +899,7 @@
899 899  **AB aa 02 03 xx xx xx 02 yy yy**  same as **AT+SEARCHaa=2,xx xx xx+yy yy**
900 900  
901 901  
908 +
902 902  ==== Fast command to handle MODBUS device ====
903 903  
904 904  AT+MBFUN is valid since v1.3 firmware version. The command is for fast configure to read Modbus devices. It is only valid for the devices which follow the [[MODBUS-RTU protocol>>url:https://www.modbustools.com/modbus.html]].
1654133913295-597.png