... ... @@ -744,7 +744,6 @@
744 744  * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for RS485-BL.  User can see these commands below:
745 745  
746 746  
747 -
748 748  === 3.5.1 Common Commands: ===
749 749  
750 750  They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
... ... @@ -752,6 +752,7 @@
752 752  
753 753  === 3.5.2 Sensor related commands: ===
754 754  
754 +(% class="wikigeneratedid" %)
755 755  ==== ====
756 756  
757 757  ==== **Choose Device Type (RS485 or TTL)** ====
... ... @@ -760,15 +760,9 @@
760 760  
761 761  * **AT Command**
762 762  
763 -(% class="box infomessage" %)
764 -(((
765 765  **AT+MOD=1** ~/~/ Set to support RS485-MODBUS type sensors. User can connect multiply RS485 , Modbus sensors to the A / B pins.
766 -)))
767 767  
768 -(% class="box infomessage" %)
769 -(((
770 770  **AT+MOD=2** ~/~/ Set to support TTL Level sensors, User can connect one TTL Sensor to the TXD/RXD/GND pins.
771 -)))
772 772  
773 773  
774 774  * **Downlink Payload**
... ... @@ -783,10 +783,7 @@
783 783  
784 784  * **AT Command**
785 785  
786 -(% class="box infomessage" %)
787 -(((
788 -**AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m**
789 -)))
780 +AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m
790 790  
791 791  m: 0: no CRC; 1: add CRC-16/MODBUS in the end of this command.
792 792  
... ... @@ -807,15 +807,15 @@
807 807  
808 808  To connect a Modbus Alarm with below commands.
809 809  
810 -* The command to active alarm is: 0A 05 00 04 00 01 **4C B0**. Where 0A 05 00 04 00 01 is the Modbus command to read the register 00 40 where stored the DI status. The 4C B0 is the CRC-16/MODBUS which calculate manually.
801 +* The command to active alarm is: 0A 05 00 04 00 01 4C B0. Where 0A 05 00 04 00 01 is the Modbus command to read the register 00 40 where stored the DI status. The 4C B0 is the CRC-16/MODBUS which calculate manually.
811 811  
812 -* The command to deactivate alarm is: 0A 05 00 04 00 00 **8D 70**. Where 0A 05 00 04 00 00 is the Modbus command to read the register 00 40 where stored the DI status. The 8D 70 is the CRC-16/MODBUS which calculate manually.
803 +* The command to deactivate alarm is: 0A 05 00 04 00 00 8D 70. Where 0A 05 00 04 00 00 is the Modbus command to read the register 00 40 where stored the DI status. The 8D 70 is the CRC-16/MODBUS which calculate manually.
813 813  
814 814  So if user want to use downlink command to control to RS485 Alarm, he can use:
815 815  
816 -(% style="color:#037691" %)**A8 01 06 0A 05 00 04 00 01 00**(%%): to activate the RS485 Alarm
807 +**A8 01 06 0A 05 00 04 00 01 00**: to activate the RS485 Alarm
817 817  
818 -(% style="color:#037691" %)**A8 01 06 0A 05 00 04 00 00 00**(%%): to deactivate the RS485 Alarm
809 +**A8 01 06 0A 05 00 04 00 00 00**: to deactivate the RS485 Alarm
819 819  
820 820  A8 is type code and 01 means add CRC-16/MODBUS at the end, the 3^^rd^^ byte is 06, means the next 6 bytes are the command to be sent to the RS485 network, the final byte 00 means this command don’t need to acquire output.
821 821  
... ... @@ -824,32 +824,29 @@
824 824  
825 825  Check TTL Sensor return:
826 826  
827 -[[image:1654132684752-193.png]]
818 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image024.png]]
828 828  
829 829  
830 830  
831 -==== **Set Payload version** ====
832 832  
823 +==== Set Payload version ====
824 +
833 833  This is the first byte of the uplink payload. RS485-BL can connect to different sensors. User can set the PAYVER field to tell server how to decode the current payload.
834 834  
835 -* **AT Command:**
827 +* AT Command:
836 836  
837 -(% class="box infomessage" %)
838 -(((
839 -**AT+PAYVER: Set PAYVER field = 1**
840 -)))
829 +AT+PAYVER: Set PAYVER field = 1
841 841  
842 842  
843 -* **Downlink Payload:**
832 +* Downlink Payload:
844 844  
845 -**0xAE 01**  ~-~-> Set PAYVER field =  0x01
834 +0xAE 01   à Set PAYVER field =  0x01
846 846  
847 -**0xAE 0F**   ~-~-> Set PAYVER field =  0x0F
836 +0xAE 0F   à Set PAYVER field =  0x0F
848 848  
849 849  
839 +==== Set RS485 Sampling Commands ====
850 850  
851 -==== **Set RS485 Sampling Commands** ====
852 -
853 853  AT+COMMANDx, AT+DATACUTx and AT+SEARCHx
854 854  
855 855  These three commands are used to configure how the RS485-BL polling data from Modbus device. Detail of usage please see : [[polling RS485 device>>path:#polling_485]].
... ... @@ -1069,13 +1069,13 @@
1069 1069  
1070 1070  
1071 1071  
1072 -1.
1060 +1.
1073 1073  11. Buttons
1074 1074  
1075 1075  |**Button**|**Feature**
1076 1076  |**RST**|Reboot RS485-BL
1077 1077  
1078 -1.
1066 +1.
1079 1079  11. +3V3 Output
1080 1080  
1081 1081  RS485-BL has a Controllable +3V3 output, user can use this output to power external sensor.
... ... @@ -1093,7 +1093,7 @@
1093 1093  By default, the AT+3V3T=0. This is a special case, means the +3V3 output is always on at any time
1094 1094  
1095 1095  
1096 -1.
1084 +1.
1097 1097  11. +5V Output
1098 1098  
1099 1099  RS485-BL has a Controllable +5V output, user can use this output to power external sensor.
... ... @@ -1113,13 +1113,13 @@
1113 1113  
1114 1114  
1115 1115  
1116 -1.
1104 +1.
1117 1117  11. LEDs
1118 1118  
1119 1119  |**LEDs**|**Feature**
1120 1120  |**LED1**|Blink when device transmit a packet.
1121 1121  
1122 -1.
1110 +1.
1123 1123  11. Switch Jumper
1124 1124  
1125 1125  |**Switch Jumper**|**Feature**
... ... @@ -1165,7 +1165,7 @@
1165 1165  
1166 1166  
1167 1167  
1168 -1.
1156 +1.
1169 1169  11. Common AT Command Sequence
1170 1170  111. Multi-channel ABP mode (Use with SX1301/LG308)
1171 1171  
... ... @@ -1184,8 +1184,8 @@
1184 1184  
1185 1185  ATZ
1186 1186  
1187 -1.
1188 -11.
1175 +1.
1176 +11.
1189 1189  111. Single-channel ABP mode (Use with LG01/LG02)
1190 1190  
1191 1191  AT+FDR   Reset Parameters to Factory Default, Keys Reserve
... ... @@ -1260,7 +1260,7 @@
1260 1260  [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image035.png]] [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image036.png]]
1261 1261  
1262 1262  
1263 -1.
1251 +1.
1264 1264  11. How to change the LoRa Frequency Bands/Region?
1265 1265  
1266 1266  User can follow the introduction for [[how to upgrade image>>path:#upgrade_image]]. When download the images, choose the required image file for download.
... ... @@ -1267,7 +1267,7 @@
1267 1267  
1268 1268  
1269 1269  
1270 -1.
1258 +1.
1271 1271  11. How many RS485-Slave can RS485-BL connects?
1272 1272  
1273 1273  The RS485-BL can support max 32 RS485 devices. Each uplink command of RS485-BL can support max 16 different RS485 command. So RS485-BL can support max 16 RS485 devices pre-program in the device for uplink. For other devices no pre-program, user can use the [[downlink message (type code 0xA8) to poll their info>>path:#downlink_A8]].
... ... @@ -1284,7 +1284,7 @@
1284 1284  
1285 1285  
1286 1286  
1287 -1.
1275 +1.
1288 1288  11. Why I can’t join TTN V3 in US915 /AU915 bands?
1289 1289  
1290 1290  It might about the channels mapping. Please see for detail.