Changes for page RS485-BL – Waterproof RS485 to LoRaWAN Converter
Last modified by Xiaoling on 2025/04/23 15:57
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -744,7 +744,6 @@ 744 744 * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for RS485-BL. User can see these commands below: 745 745 746 746 747 - 748 748 === 3.5.1 Common Commands: === 749 749 750 750 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] ... ... @@ -752,6 +752,7 @@ 752 752 753 753 === 3.5.2 Sensor related commands: === 754 754 754 +(% class="wikigeneratedid" %) 755 755 ==== ==== 756 756 757 757 ==== **Choose Device Type (RS485 or TTL)** ==== ... ... @@ -760,15 +760,9 @@ 760 760 761 761 * **AT Command** 762 762 763 -(% class="box infomessage" %) 764 -((( 765 765 **AT+MOD=1** ~/~/ Set to support RS485-MODBUS type sensors. User can connect multiply RS485 , Modbus sensors to the A / B pins. 766 -))) 767 767 768 -(% class="box infomessage" %) 769 -((( 770 770 **AT+MOD=2** ~/~/ Set to support TTL Level sensors, User can connect one TTL Sensor to the TXD/RXD/GND pins. 771 -))) 772 772 773 773 774 774 * **Downlink Payload** ... ... @@ -783,10 +783,7 @@ 783 783 784 784 * **AT Command** 785 785 786 -(% class="box infomessage" %) 787 -((( 788 -**AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m** 789 -))) 780 +AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m 790 790 791 791 m: 0: no CRC; 1: add CRC-16/MODBUS in the end of this command. 792 792 ... ... @@ -807,15 +807,15 @@ 807 807 808 808 To connect a Modbus Alarm with below commands. 809 809 810 -* The command to active alarm is: 0A 05 00 04 00 01 **4C B0**. Where 0A 05 00 04 00 01 is the Modbus command to read the register 00 40 where stored the DI status. The 4C B0 is the CRC-16/MODBUS which calculate manually.801 +* The command to active alarm is: 0A 05 00 04 00 01 4C B0. Where 0A 05 00 04 00 01 is the Modbus command to read the register 00 40 where stored the DI status. The 4C B0 is the CRC-16/MODBUS which calculate manually. 811 811 812 -* The command to deactivate alarm is: 0A 05 00 04 00 00 **8D 70**. Where 0A 05 00 04 00 00 is the Modbus command to read the register 00 40 where stored the DI status. The 8D 70 is the CRC-16/MODBUS which calculate manually.803 +* The command to deactivate alarm is: 0A 05 00 04 00 00 8D 70. Where 0A 05 00 04 00 00 is the Modbus command to read the register 00 40 where stored the DI status. The 8D 70 is the CRC-16/MODBUS which calculate manually. 813 813 814 814 So if user want to use downlink command to control to RS485 Alarm, he can use: 815 815 816 - (% style="color:#037691" %)**A8 01 06 0A 05 00 04 00 01 00**(%%): to activate the RS485 Alarm807 +**A8 01 06 0A 05 00 04 00 01 00**: to activate the RS485 Alarm 817 817 818 - (% style="color:#037691" %)**A8 01 06 0A 05 00 04 00 00 00**(%%): to deactivate the RS485 Alarm809 +**A8 01 06 0A 05 00 04 00 00 00**: to deactivate the RS485 Alarm 819 819 820 820 A8 is type code and 01 means add CRC-16/MODBUS at the end, the 3^^rd^^ byte is 06, means the next 6 bytes are the command to be sent to the RS485 network, the final byte 00 means this command don’t need to acquire output. 821 821 ... ... @@ -824,32 +824,29 @@ 824 824 825 825 Check TTL Sensor return: 826 826 827 -[[image: 1654132684752-193.png]]818 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image024.png]] 828 828 829 829 830 830 831 -==== **Set Payload version** ==== 832 832 823 +==== Set Payload version ==== 824 + 833 833 This is the first byte of the uplink payload. RS485-BL can connect to different sensors. User can set the PAYVER field to tell server how to decode the current payload. 834 834 835 -* **AT Command:**827 +* AT Command: 836 836 837 -(% class="box infomessage" %) 838 -((( 839 -**AT+PAYVER: Set PAYVER field = 1** 840 -))) 829 +AT+PAYVER: Set PAYVER field = 1 841 841 842 842 843 -* **Downlink Payload:**832 +* Downlink Payload: 844 844 845 - **0xAE 01**~-~->Set PAYVER field = 0x01834 +0xAE 01 à Set PAYVER field = 0x01 846 846 847 - **0xAE 0F**~-~->Set PAYVER field = 0x0F836 +0xAE 0F à Set PAYVER field = 0x0F 848 848 849 849 839 +==== Set RS485 Sampling Commands ==== 850 850 851 -==== **Set RS485 Sampling Commands** ==== 852 - 853 853 AT+COMMANDx, AT+DATACUTx and AT+SEARCHx 854 854 855 855 These three commands are used to configure how the RS485-BL polling data from Modbus device. Detail of usage please see : [[polling RS485 device>>path:#polling_485]]. ... ... @@ -1069,13 +1069,13 @@ 1069 1069 1070 1070 1071 1071 1072 -1. 1060 +1. 1073 1073 11. Buttons 1074 1074 1075 1075 |**Button**|**Feature** 1076 1076 |**RST**|Reboot RS485-BL 1077 1077 1078 -1. 1066 +1. 1079 1079 11. +3V3 Output 1080 1080 1081 1081 RS485-BL has a Controllable +3V3 output, user can use this output to power external sensor. ... ... @@ -1093,7 +1093,7 @@ 1093 1093 By default, the AT+3V3T=0. This is a special case, means the +3V3 output is always on at any time 1094 1094 1095 1095 1096 -1. 1084 +1. 1097 1097 11. +5V Output 1098 1098 1099 1099 RS485-BL has a Controllable +5V output, user can use this output to power external sensor. ... ... @@ -1113,13 +1113,13 @@ 1113 1113 1114 1114 1115 1115 1116 -1. 1104 +1. 1117 1117 11. LEDs 1118 1118 1119 1119 |**LEDs**|**Feature** 1120 1120 |**LED1**|Blink when device transmit a packet. 1121 1121 1122 -1. 1110 +1. 1123 1123 11. Switch Jumper 1124 1124 1125 1125 |**Switch Jumper**|**Feature** ... ... @@ -1165,7 +1165,7 @@ 1165 1165 1166 1166 1167 1167 1168 -1. 1156 +1. 1169 1169 11. Common AT Command Sequence 1170 1170 111. Multi-channel ABP mode (Use with SX1301/LG308) 1171 1171 ... ... @@ -1184,8 +1184,8 @@ 1184 1184 1185 1185 ATZ 1186 1186 1187 -1. 1188 -11. 1175 +1. 1176 +11. 1189 1189 111. Single-channel ABP mode (Use with LG01/LG02) 1190 1190 1191 1191 AT+FDR Reset Parameters to Factory Default, Keys Reserve ... ... @@ -1260,7 +1260,7 @@ 1260 1260 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image035.png]] [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image036.png]] 1261 1261 1262 1262 1263 -1. 1251 +1. 1264 1264 11. How to change the LoRa Frequency Bands/Region? 1265 1265 1266 1266 User can follow the introduction for [[how to upgrade image>>path:#upgrade_image]]. When download the images, choose the required image file for download. ... ... @@ -1267,7 +1267,7 @@ 1267 1267 1268 1268 1269 1269 1270 -1. 1258 +1. 1271 1271 11. How many RS485-Slave can RS485-BL connects? 1272 1272 1273 1273 The RS485-BL can support max 32 RS485 devices. Each uplink command of RS485-BL can support max 16 different RS485 command. So RS485-BL can support max 16 RS485 devices pre-program in the device for uplink. For other devices no pre-program, user can use the [[downlink message (type code 0xA8) to poll their info>>path:#downlink_A8]]. ... ... @@ -1284,7 +1284,7 @@ 1284 1284 1285 1285 1286 1286 1287 -1. 1275 +1. 1288 1288 11. Why I can’t join TTN V3 in US915 /AU915 bands? 1289 1289 1290 1290 It might about the channels mapping. Please see for detail.