Changes for page RS485-BL – Waterproof RS485 to LoRaWAN Converter
Last modified by Xiaoling on 2025/04/23 15:57
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -743,8 +743,6 @@ 743 743 744 744 * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for RS485-BL. User can see these commands below: 745 745 746 - 747 - 748 748 === 3.5.1 Common Commands: === 749 749 750 750 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] ... ... @@ -802,7 +802,6 @@ 802 802 * XX XX XX XX: RS485 command total NN bytes 803 803 * YY: How many bytes will be uplink from the return of this RS485 command, if YY=0, RS485-BL will execute the downlink command without uplink; if YY>0, RS485-BL will uplink total YY bytes from the output of this RS485 command 804 804 805 - 806 806 **Example 1:** 807 807 808 808 To connect a Modbus Alarm with below commands. ... ... @@ -842,32 +842,42 @@ 842 842 843 843 * **Downlink Payload:** 844 844 845 -0xAE 01 ~-~-> Set PAYVER field = 0x01 842 +**0xAE 01** ~-~-> Set PAYVER field = 0x01 846 846 847 -0xAE 0F ~-~-> Set PAYVER field = 0x0F 844 +**0xAE 0F** ~-~-> Set PAYVER field = 0x0F 848 848 849 849 850 -==== Set RS485 Sampling Commands ==== 851 851 848 +==== **Set RS485 Sampling Commands** ==== 849 + 852 852 AT+COMMANDx, AT+DATACUTx and AT+SEARCHx 853 853 854 -These three commands are used to configure how the RS485-BL polling data from Modbus device. Detail of usage please see : [[polling RS485 device>> path:#polling_485]].852 +These three commands are used to configure how the RS485-BL polling data from Modbus device. Detail of usage please see : [[polling RS485 device>>||anchor="H3.3.3Configurereadcommandsforeachsampling"]]. 855 855 856 856 857 -* AT Command: 855 +* **AT Command:** 858 858 859 -AT+COMMANDx: Configure RS485 read command to sensor. 857 +(% class="box infomessage" %) 858 +((( 859 +**AT+COMMANDx: Configure RS485 read command to sensor.** 860 +))) 860 860 861 -AT+DATACUTx: Configure how to handle return from RS485 devices. 862 +(% class="box infomessage" %) 863 +((( 864 +**AT+DATACUTx: Configure how to handle return from RS485 devices.** 865 +))) 862 862 863 -AT+SEARCHx: Configure search command 867 +(% class="box infomessage" %) 868 +((( 869 +**AT+SEARCHx: Configure search command** 870 +))) 864 864 865 865 866 -* Downlink Payload: 873 +* **Downlink Payload:** 867 867 868 -0xAF downlink command can be used to set AT+COMMANDx or AT+DATACUTx. 875 +**0xAF** downlink command can be used to set AT+COMMANDx or AT+DATACUTx. 869 869 870 -Note: if user use AT+COMMANDx to add a new command, he also need to send AT+DATACUTx downlink. 877 +(% style="color:red" %)**Note**(%%): if user use AT+COMMANDx to add a new command, he also need to send AT+DATACUTx downlink. 871 871 872 872 Format: AF MM NN LL XX XX XX XX YY 873 873 ... ... @@ -874,23 +874,23 @@ 874 874 Where: 875 875 876 876 * MM: the ATCOMMAND or AT+DATACUT to be set. Value from 01 ~~ 0F, 877 -* NN: 0: no CRC; 1: add CRC-16/MODBUS ; 2: set the AT+DATACUT value. 878 -* LL: The length of AT+COMMAND or AT+DATACUT command 884 +* NN: 0: no CRC; 1: add CRC-16/MODBUS ; 2: set the AT+DATACUT value. 885 +* LL: The length of AT+COMMAND or AT+DATACUT command 879 879 * XX XX XX XX: AT+COMMAND or AT+DATACUT command 880 -* YY: If YY=0, RS485-BL will execute the downlink command without uplink; if YY=1, RS485-BL will execute an uplink after got this command. 887 +* YY: If YY=0, RS485-BL will execute the downlink command without uplink; if YY=1, RS485-BL will execute an uplink after got this command. 881 881 882 -Example: 889 +**Example:** 883 883 884 -**AF 03 01 06 0A 05 00 04 00 01 00**: Same as AT+COMMAND3=0A 05 00 04 00 01,1 891 +(% style="color:#037691" %)**AF 03 01 06 0A 05 00 04 00 01 00**(%%): Same as AT+COMMAND3=0A 05 00 04 00 01,1 885 885 886 -**AF 03 02 06 10 01 05 06 09 0A 00**: Same as AT+DATACUT3=**16**,**1**,**5+6+9+10** 893 +(% style="color:#037691" %)**AF 03 02 06**(% style="color:orange" %)** 10 **(% style="color:red" %)**01 **(% style="color:green" %)**05 06 09 0A**(% style="color:#037691" %)** 00**(%%): Same as AT+DATACUT3=(% style="color:orange" %)**16**(%%),(% style="color:red" %)**1**(%%),(% style="color:green" %)**5+6+9+10** 887 887 888 -**AF 03 02 06 0B 02 05 07 08 0A 00**: Same as AT+DATACUT3=**11**,**2**,**5~~7+8~~10** 895 +(% style="color:#037691" %)**AF 03 02 06 **(% style="color:orange" %)**0B**(% style="color:red" %)** 02 **(% style="color:green" %)**05 07 08 0A **(% style="color:#037691" %)**00**(%%): Same as AT+DATACUT3=(% style="color:orange" %)**11**(%%),(% style="color:red" %)**2**(%%),(% style="color:green" %)**5~~7+8~~10** 889 889 890 890 891 -0xAB downlink command can be used for set AT+SEARCHx 898 +**0xAB** downlink command can be used for set AT+SEARCHx 892 892 893 -Example: **AB aa 01 03 xx xx xx** (03 here means there are total 3 bytes after 03) So 900 +**Example:** **AB aa 01 03 xx xx xx** (03 here means there are total 3 bytes after 03) So 894 894 895 895 * AB aa 01 03 xx xx xx same as AT+SEARCHaa=1,xx xx xx 896 896 * AB aa 02 03 xx xx xx 02 yy yy(03 means there are 3 bytes after 03, they are xx xx xx;02 means there are 2 bytes after 02, they are yy yy) so the commands ... ... @@ -898,6 +898,7 @@ 898 898 **AB aa 02 03 xx xx xx 02 yy yy** same as **AT+SEARCHaa=2,xx xx xx+yy yy** 899 899 900 900 908 + 901 901 ==== Fast command to handle MODBUS device ==== 902 902 903 903 AT+MBFUN is valid since v1.3 firmware version. The command is for fast configure to read Modbus devices. It is only valid for the devices which follow the [[MODBUS-RTU protocol>>url:https://www.modbustools.com/modbus.html]].