Last modified by Xiaoling on 2025/04/23 15:57

From version 30.2
edited by Xiaoling
on 2022/06/02 09:18
Change comment: There is no comment for this version
To version 30.5
edited by Xiaoling
on 2022/06/02 09:26
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -744,7 +744,6 @@
744 744  * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for RS485-BL.  User can see these commands below:
745 745  
746 746  
747 -
748 748  === 3.5.1 Common Commands: ===
749 749  
750 750  They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
... ... @@ -760,9 +760,15 @@
760 760  
761 761  * **AT Command**
762 762  
762 +(% class="box infomessage" %)
763 +(((
763 763  **AT+MOD=1** ~/~/ Set to support RS485-MODBUS type sensors. User can connect multiply RS485 , Modbus sensors to the A / B pins.
765 +)))
764 764  
767 +(% class="box infomessage" %)
768 +(((
765 765  **AT+MOD=2** ~/~/ Set to support TTL Level sensors, User can connect one TTL Sensor to the TXD/RXD/GND pins.
770 +)))
766 766  
767 767  
768 768  * **Downlink Payload**
... ... @@ -777,7 +777,10 @@
777 777  
778 778  * **AT Command**
779 779  
780 -AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m
785 +(% class="box infomessage" %)
786 +(((
787 +**AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m**
788 +)))
781 781  
782 782  m: 0: no CRC; 1: add CRC-16/MODBUS in the end of this command.
783 783  
... ... @@ -818,28 +818,31 @@
818 818  
819 819  
820 820  
829 +==== **Set Payload version** ====
821 821  
822 -==== Set Payload version ====
823 -
824 824  This is the first byte of the uplink payload. RS485-BL can connect to different sensors. User can set the PAYVER field to tell server how to decode the current payload.
825 825  
826 -* AT Command:
833 +* **AT Command:**
827 827  
828 -AT+PAYVER: Set PAYVER field = 1
835 +(% class="box infomessage" %)
836 +(((
837 +**AT+PAYVER: Set PAYVER field = 1**
838 +)))
829 829  
830 830  
831 -* Downlink Payload:
841 +* **Downlink Payload:**
832 832  
833 -0xAE 01   à Set PAYVER field =  0x01
843 +**0xAE 01**  ~-~-> Set PAYVER field =  0x01
834 834  
835 -0xAE 0F   à Set PAYVER field =  0x0F
845 +**0xAE 0F**   ~-~-> Set PAYVER field =  0x0F
836 836  
837 837  
838 -==== Set RS485 Sampling Commands ====
839 839  
849 +==== **Set RS485 Sampling Commands** ====
850 +
840 840  AT+COMMANDx, AT+DATACUTx and AT+SEARCHx
841 841  
842 -These three commands are used to configure how the RS485-BL polling data from Modbus device. Detail of usage please see : [[polling RS485 device>>path:#polling_485]].
853 +These three commands are used to configure how the RS485-BL polling data from Modbus device. Detail of usage please see : [[polling RS485 device>>||anchor="H3.3.3Configurereadcommandsforeachsampling"]].
843 843  
844 844  
845 845  * AT Command:
... ... @@ -1056,13 +1056,13 @@
1056 1056  
1057 1057  
1058 1058  
1059 -1.
1070 +1.
1060 1060  11. Buttons
1061 1061  
1062 1062  |**Button**|**Feature**
1063 1063  |**RST**|Reboot RS485-BL
1064 1064  
1065 -1.
1076 +1.
1066 1066  11. +3V3 Output
1067 1067  
1068 1068  RS485-BL has a Controllable +3V3 output, user can use this output to power external sensor.
... ... @@ -1080,7 +1080,7 @@
1080 1080  By default, the AT+3V3T=0. This is a special case, means the +3V3 output is always on at any time
1081 1081  
1082 1082  
1083 -1.
1094 +1.
1084 1084  11. +5V Output
1085 1085  
1086 1086  RS485-BL has a Controllable +5V output, user can use this output to power external sensor.
... ... @@ -1100,13 +1100,13 @@
1100 1100  
1101 1101  
1102 1102  
1103 -1.
1114 +1.
1104 1104  11. LEDs
1105 1105  
1106 1106  |**LEDs**|**Feature**
1107 1107  |**LED1**|Blink when device transmit a packet.
1108 1108  
1109 -1.
1120 +1.
1110 1110  11. Switch Jumper
1111 1111  
1112 1112  |**Switch Jumper**|**Feature**
... ... @@ -1152,7 +1152,7 @@
1152 1152  
1153 1153  
1154 1154  
1155 -1.
1166 +1.
1156 1156  11. Common AT Command Sequence
1157 1157  111. Multi-channel ABP mode (Use with SX1301/LG308)
1158 1158  
... ... @@ -1171,8 +1171,8 @@
1171 1171  
1172 1172  ATZ
1173 1173  
1174 -1.
1175 -11.
1185 +1.
1186 +11.
1176 1176  111. Single-channel ABP mode (Use with LG01/LG02)
1177 1177  
1178 1178  AT+FDR   Reset Parameters to Factory Default, Keys Reserve
... ... @@ -1247,7 +1247,7 @@
1247 1247  [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image035.png]] [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image036.png]]
1248 1248  
1249 1249  
1250 -1.
1261 +1.
1251 1251  11. How to change the LoRa Frequency Bands/Region?
1252 1252  
1253 1253  User can follow the introduction for [[how to upgrade image>>path:#upgrade_image]]. When download the images, choose the required image file for download.
... ... @@ -1254,7 +1254,7 @@
1254 1254  
1255 1255  
1256 1256  
1257 -1.
1268 +1.
1258 1258  11. How many RS485-Slave can RS485-BL connects?
1259 1259  
1260 1260  The RS485-BL can support max 32 RS485 devices. Each uplink command of RS485-BL can support max 16 different RS485 command. So RS485-BL can support max 16 RS485 devices pre-program in the device for uplink. For other devices no pre-program, user can use the [[downlink message (type code 0xA8) to poll their info>>path:#downlink_A8]].
... ... @@ -1271,7 +1271,7 @@
1271 1271  
1272 1272  
1273 1273  
1274 -1.
1285 +1.
1275 1275  11. Why I can’t join TTN V3 in US915 /AU915 bands?
1276 1276  
1277 1277  It might about the channels mapping. Please see for detail.