Last modified by Xiaoling on 2025/04/23 15:57

From version 30.1
edited by Xiaoling
on 2022/06/02 09:18
Change comment: Uploaded new attachment "1654132684752-193.png", version {1}
To version 29.36
edited by Xiaoling
on 2022/06/02 08:59
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -316,6 +316,7 @@
316 316  )))
317 317  )))
318 318  
319 +
319 319  === 3.3.2 Configure sensors ===
320 320  
321 321  (((
... ... @@ -627,8 +627,6 @@
627 627  
628 628  (((
629 629  **0xA8 command**: Send a command to RS485-BL and uplink the output from sensors.
630 -
631 -
632 632  )))
633 633  
634 634  === 3.3.6 Uplink on Interrupt ===
... ... @@ -637,7 +637,6 @@
637 637  
638 638  [[image:1653273818896-432.png]]
639 639  
640 -
641 641  (((
642 642  AT+INTMOD=0  Disable Interrupt
643 643  )))
... ... @@ -652,8 +652,6 @@
652 652  
653 653  (((
654 654  AT+INTMOD=3  Interrupt trigger by rising edge.
655 -
656 -
657 657  )))
658 658  
659 659  == 3.4 Uplink Payload ==
... ... @@ -681,49 +681,47 @@
681 681  Below is the decoder for the first 3 bytes. The rest bytes are dynamic depends on different RS485 sensors.
682 682  
683 683  (((
684 -{{{function Decoder(bytes, port) {}}}
680 +function Decoder(bytes, port) {
685 685  )))
686 686  
687 687  (((
688 -{{{//Payload Formats of RS485-BL Deceive}}}
684 +~/~/Payload Formats of RS485-BL Deceive
689 689  )))
690 690  
691 691  (((
692 -{{{return {}}}
688 +return {
693 693  )))
694 694  
695 695  (((
696 -{{{ //Battery,units:V}}}
692 + ~/~/Battery,units:V
697 697  )))
698 698  
699 699  (((
700 -{{{ BatV:((bytes[0]<<8 | bytes[1])&0x7fff)/1000,}}}
696 + BatV:((bytes[0]<<8 | bytes[1])&0x7fff)/1000,
701 701  )))
702 702  
703 703  (((
704 -{{{ //GPIO_EXTI }}}
700 + ~/~/GPIO_EXTI 
705 705  )))
706 706  
707 707  (((
708 -{{{ EXTI_Trigger:(bytes[0] & 0x80)? "TRUE":"FALSE",}}}
704 + EXTI_Trigger:(bytes[0] & 0x80)? "TRUE":"FALSE",
709 709  )))
710 710  
711 711  (((
712 -{{{ //payload of version}}}
708 + ~/~/payload of version
713 713  )))
714 714  
715 715  (((
716 -{{{ Pay_ver:bytes[2],}}}
712 + Pay_ver:bytes[2],
717 717  )))
718 718  
719 719  (((
720 -{{{ }; }}}
716 + };
721 721  )))
722 722  
723 723  (((
724 -}
725 -
726 -
720 + }
727 727  )))
728 728  
729 729  (((
... ... @@ -732,33 +732,32 @@
732 732  
733 733  [[image:1653274001211-372.png||height="192" width="732"]]
734 734  
735 -
736 736  == 3.5 Configure RS485-BL via AT or Downlink ==
737 737  
738 -User can configure RS485-BL via AT Commands or LoRaWAN Downlink Commands
731 +User can configure RS485-BL via [[AT Commands >>path:#_​Using_the_AT]]or LoRaWAN Downlink Commands
739 739  
740 740  There are two kinds of Commands:
741 741  
742 -* (% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
735 +* **Common Commands**: They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: http:~/~/wiki.dragino.com/index.php?title=End_Device_AT_Commands_and_Downlink_Commands
743 743  
744 -* (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for RS485-BL.  User can see these commands below:
737 +* **Sensor Related Commands**: These commands are special designed for RS485-BL.  User can see these commands below:
745 745  
739 +1.
740 +11.
741 +111. Common Commands:
746 746  
747 -=== 3.5.1 Common Commands: ===
743 +They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[http:~~/~~/wiki.dragino.com/index.php?title=End_Device_AT_Commands_and_Downlink_Commands>>url:http://wiki.dragino.com/index.php?title=End_Device_AT_Commands_and_Downlink_Commands]]
748 748  
749 -They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
750 750  
746 +1.
747 +11.
748 +111. Sensor related commands:
751 751  
752 -=== 3.5.2 Sensor related commands: ===
750 +==== Choose Device Type (RS485 or TTL) ====
753 753  
754 -(% class="wikigeneratedid" %)
755 -==== ====
756 -
757 -==== **Choose Device Type (RS485 or TTL)** ====
758 -
759 759  RS485-BL can connect to either RS485 sensors or TTL sensor. User need to specify what type of sensor need to connect.
760 760  
761 -* **AT Command**
754 +* AT Command
762 762  
763 763  **AT+MOD=1** ~/~/ Set to support RS485-MODBUS type sensors. User can connect multiply RS485 , Modbus sensors to the A / B pins.
764 764  
... ... @@ -765,17 +765,17 @@
765 765  **AT+MOD=2** ~/~/ Set to support TTL Level sensors, User can connect one TTL Sensor to the TXD/RXD/GND pins.
766 766  
767 767  
768 -* **Downlink Payload**
761 +* Downlink Payload
769 769  
770 -**0A aa**  ~-~->  same as AT+MOD=aa
763 +**0A aa**     à same as AT+MOD=aa
771 771  
772 772  
773 773  
774 -==== **RS485 Debug Command (AT+CFGDEV)** ====
767 +==== [[RS485 Debug Command>>path:#downlink_A8]] (AT+CFGDEV) ====
775 775  
776 776  This command is used to configure the RS485 or TTL sensors; they won’t be used during sampling.
777 777  
778 -* **AT Command**
771 +* AT Command
779 779  
780 780  AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m
781 781  
... ... @@ -782,8 +782,9 @@
782 782  m: 0: no CRC; 1: add CRC-16/MODBUS in the end of this command.
783 783  
784 784  
785 -* **Downlink Payload**
786 786  
779 +* Downlink Payload
780 +
787 787  Format: A8 MM NN XX XX XX XX YY
788 788  
789 789  Where:
... ... @@ -793,7 +793,6 @@
793 793  * XX XX XX XX: RS485 command total NN bytes
794 794  * YY: How many bytes will be uplink from the return of this RS485 command, if YY=0, RS485-BL will execute the downlink command without uplink; if YY>0, RS485-BL will uplink total YY bytes from the output of this RS485 command
795 795  
796 -
797 797  **Example 1:**
798 798  
799 799  To connect a Modbus Alarm with below commands.
... ... @@ -1057,13 +1057,13 @@
1057 1057  
1058 1058  
1059 1059  
1060 -1.
1053 +1.
1061 1061  11. Buttons
1062 1062  
1063 1063  |**Button**|**Feature**
1064 1064  |**RST**|Reboot RS485-BL
1065 1065  
1066 -1.
1059 +1.
1067 1067  11. +3V3 Output
1068 1068  
1069 1069  RS485-BL has a Controllable +3V3 output, user can use this output to power external sensor.
... ... @@ -1081,7 +1081,7 @@
1081 1081  By default, the AT+3V3T=0. This is a special case, means the +3V3 output is always on at any time
1082 1082  
1083 1083  
1084 -1.
1077 +1.
1085 1085  11. +5V Output
1086 1086  
1087 1087  RS485-BL has a Controllable +5V output, user can use this output to power external sensor.
... ... @@ -1101,13 +1101,13 @@
1101 1101  
1102 1102  
1103 1103  
1104 -1.
1097 +1.
1105 1105  11. LEDs
1106 1106  
1107 1107  |**LEDs**|**Feature**
1108 1108  |**LED1**|Blink when device transmit a packet.
1109 1109  
1110 -1.
1103 +1.
1111 1111  11. Switch Jumper
1112 1112  
1113 1113  |**Switch Jumper**|**Feature**
... ... @@ -1153,7 +1153,7 @@
1153 1153  
1154 1154  
1155 1155  
1156 -1.
1149 +1.
1157 1157  11. Common AT Command Sequence
1158 1158  111. Multi-channel ABP mode (Use with SX1301/LG308)
1159 1159  
... ... @@ -1172,8 +1172,8 @@
1172 1172  
1173 1173  ATZ
1174 1174  
1175 -1.
1176 -11.
1168 +1.
1169 +11.
1177 1177  111. Single-channel ABP mode (Use with LG01/LG02)
1178 1178  
1179 1179  AT+FDR   Reset Parameters to Factory Default, Keys Reserve
... ... @@ -1248,7 +1248,7 @@
1248 1248  [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image035.png]] [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image036.png]]
1249 1249  
1250 1250  
1251 -1.
1244 +1.
1252 1252  11. How to change the LoRa Frequency Bands/Region?
1253 1253  
1254 1254  User can follow the introduction for [[how to upgrade image>>path:#upgrade_image]]. When download the images, choose the required image file for download.
... ... @@ -1255,7 +1255,7 @@
1255 1255  
1256 1256  
1257 1257  
1258 -1.
1251 +1.
1259 1259  11. How many RS485-Slave can RS485-BL connects?
1260 1260  
1261 1261  The RS485-BL can support max 32 RS485 devices. Each uplink command of RS485-BL can support max 16 different RS485 command. So RS485-BL can support max 16 RS485 devices pre-program in the device for uplink. For other devices no pre-program, user can use the [[downlink message (type code 0xA8) to poll their info>>path:#downlink_A8]].
... ... @@ -1272,7 +1272,7 @@
1272 1272  
1273 1273  
1274 1274  
1275 -1.
1268 +1.
1276 1276  11. Why I can’t join TTN V3 in US915 /AU915 bands?
1277 1277  
1278 1278  It might about the channels mapping. Please see for detail.
1654132684752-193.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -22.8 KB
Content