... ... @@ -743,7 +743,6 @@
743 743  
744 744  * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for RS485-BL.  User can see these commands below:
745 745  
746 -
747 747  === 3.5.1 Common Commands: ===
748 748  
749 749  They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
... ... @@ -751,7 +751,6 @@
751 751  
752 752  === 3.5.2 Sensor related commands: ===
753 753  
754 -(% class="wikigeneratedid" %)
755 755  ==== ====
756 756  
757 757  ==== **Choose Device Type (RS485 or TTL)** ====
... ... @@ -760,9 +760,15 @@
760 760  
761 761  * **AT Command**
762 762  
761 +(% class="box infomessage" %)
762 +(((
763 763  **AT+MOD=1** ~/~/ Set to support RS485-MODBUS type sensors. User can connect multiply RS485 , Modbus sensors to the A / B pins.
764 +)))
764 764  
766 +(% class="box infomessage" %)
767 +(((
765 765  **AT+MOD=2** ~/~/ Set to support TTL Level sensors, User can connect one TTL Sensor to the TXD/RXD/GND pins.
769 +)))
766 766  
767 767  
768 768  * **Downlink Payload**
... ... @@ -777,7 +777,10 @@
777 777  
778 778  * **AT Command**
779 779  
780 -AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m
784 +(% class="box infomessage" %)
785 +(((
786 +**AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m**
787 +)))
781 781  
782 782  m: 0: no CRC; 1: add CRC-16/MODBUS in the end of this command.
783 783  
... ... @@ -797,15 +797,15 @@
797 797  
798 798  To connect a Modbus Alarm with below commands.
799 799  
800 -* The command to active alarm is: 0A 05 00 04 00 01 4C B0. Where 0A 05 00 04 00 01 is the Modbus command to read the register 00 40 where stored the DI status. The 4C B0 is the CRC-16/MODBUS which calculate manually.
807 +* The command to active alarm is: 0A 05 00 04 00 01 **4C B0**. Where 0A 05 00 04 00 01 is the Modbus command to read the register 00 40 where stored the DI status. The 4C B0 is the CRC-16/MODBUS which calculate manually.
801 801  
802 -* The command to deactivate alarm is: 0A 05 00 04 00 00 8D 70. Where 0A 05 00 04 00 00 is the Modbus command to read the register 00 40 where stored the DI status. The 8D 70 is the CRC-16/MODBUS which calculate manually.
809 +* The command to deactivate alarm is: 0A 05 00 04 00 00 **8D 70**. Where 0A 05 00 04 00 00 is the Modbus command to read the register 00 40 where stored the DI status. The 8D 70 is the CRC-16/MODBUS which calculate manually.
803 803  
804 804  So if user want to use downlink command to control to RS485 Alarm, he can use:
805 805  
806 -**A8 01 06 0A 05 00 04 00 01 00**: to activate the RS485 Alarm
813 +(% style="color:#037691" %)**A8 01 06 0A 05 00 04 00 01 00**(%%): to activate the RS485 Alarm
807 807  
808 -**A8 01 06 0A 05 00 04 00 00 00**: to deactivate the RS485 Alarm
815 +(% style="color:#037691" %)**A8 01 06 0A 05 00 04 00 00 00**(%%): to deactivate the RS485 Alarm
809 809  
810 810  A8 is type code and 01 means add CRC-16/MODBUS at the end, the 3^^rd^^ byte is 06, means the next 6 bytes are the command to be sent to the RS485 network, the final byte 00 means this command don’t need to acquire output.
811 811  
... ... @@ -814,48 +814,60 @@
814 814  
815 815  Check TTL Sensor return:
816 816  
817 -[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image024.png]]
824 +[[image:1654132684752-193.png]]
818 818  
819 819  
820 820  
828 +==== **Set Payload version** ====
821 821  
822 -==== Set Payload version ====
823 -
824 824  This is the first byte of the uplink payload. RS485-BL can connect to different sensors. User can set the PAYVER field to tell server how to decode the current payload.
825 825  
826 -* AT Command:
832 +* **AT Command:**
827 827  
828 -AT+PAYVER: Set PAYVER field = 1
834 +(% class="box infomessage" %)
835 +(((
836 +**AT+PAYVER: Set PAYVER field = 1**
837 +)))
829 829  
830 830  
831 -* Downlink Payload:
840 +* **Downlink Payload:**
832 832  
833 -0xAE 01   à Set PAYVER field =  0x01
842 +**0xAE 01**  ~-~-> Set PAYVER field =  0x01
834 834  
835 -0xAE 0F   à Set PAYVER field =  0x0F
844 +**0xAE 0F**   ~-~-> Set PAYVER field =  0x0F
836 836  
837 837  
838 -==== Set RS485 Sampling Commands ====
839 839  
848 +==== **Set RS485 Sampling Commands** ====
849 +
840 840  AT+COMMANDx, AT+DATACUTx and AT+SEARCHx
841 841  
842 -These three commands are used to configure how the RS485-BL polling data from Modbus device. Detail of usage please see : [[polling RS485 device>>path:#polling_485]].
852 +These three commands are used to configure how the RS485-BL polling data from Modbus device. Detail of usage please see : [[polling RS485 device>>||anchor="H3.3.3Configurereadcommandsforeachsampling"]].
843 843  
844 844  
845 -* AT Command:
855 +* **AT Command:**
846 846  
847 -AT+COMMANDx: Configure RS485 read command to sensor.
857 +(% class="box infomessage" %)
858 +(((
859 +**AT+COMMANDx: Configure RS485 read command to sensor.**
860 +)))
848 848  
849 -AT+DATACUTx: Configure how to handle return from RS485 devices.
862 +(% class="box infomessage" %)
863 +(((
864 +**AT+DATACUTx: Configure how to handle return from RS485 devices.**
865 +)))
850 850  
851 -AT+SEARCHx: Configure search command
867 +(% class="box infomessage" %)
868 +(((
869 +**AT+SEARCHx: Configure search command**
870 +)))
852 852  
853 853  
854 -* Downlink Payload:
873 +* **Downlink Payload:**
855 855  
856 -0xAF downlink command can be used to set AT+COMMANDx or AT+DATACUTx.
875 +**0xAF** downlink command can be used to set AT+COMMANDx or AT+DATACUTx.
857 857  
858 -Note: if user use AT+COMMANDx to add a new command, he also need to send AT+DATACUTx downlink.
877 +(% style="color:red" %)**Note**(%%): if user use AT+COMMANDx to add a new command, he also need to send AT+DATACUTx downlink.
859 859  
860 860  Format: AF MM NN LL XX XX XX XX YY
861 861  
... ... @@ -862,23 +862,23 @@
862 862  Where:
863 863  
864 864  * MM: the ATCOMMAND or AT+DATACUT to be set. Value from 01 ~~ 0F,
865 -* NN: 0: no CRC; 1: add CRC-16/MODBUS ; 2: set the AT+DATACUT value.
866 -* LL: The length of AT+COMMAND or AT+DATACUT command
884 +* NN:  0: no CRC; 1: add CRC-16/MODBUS ; 2: set the AT+DATACUT value.
885 +* LL:  The length of AT+COMMAND or AT+DATACUT command
867 867  * XX XX XX XX: AT+COMMAND or AT+DATACUT command
868 -* YY: If YY=0, RS485-BL will execute the downlink command without uplink; if YY=1, RS485-BL will execute an uplink after got this command.
887 +* YY:  If YY=0, RS485-BL will execute the downlink command without uplink; if YY=1, RS485-BL will execute an uplink after got this command.
869 869  
870 -Example:
889 +**Example:**
871 871  
872 -**AF 03 01 06 0A 05 00 04 00 01 00**: Same as AT+COMMAND3=0A 05 00 04 00 01,1
891 +(% style="color:#037691" %)**AF 03 01 06 0A 05 00 04 00 01 00**(%%): Same as AT+COMMAND3=0A 05 00 04 00 01,1
873 873  
874 -**AF 03 02 06 10 01 05 06 09 0A 00**: Same as AT+DATACUT3=**16**,**1**,**5+6+9+10**
893 +(% style="color:#037691" %)**AF 03 02 06**(% style="color:orange" %)** 10 **(% style="color:red" %)**01 **(% style="color:green" %)**05 06 09 0A**(% style="color:#037691" %)** 00**(%%): Same as AT+DATACUT3=(% style="color:orange" %)**16**(%%),(% style="color:red" %)**1**(%%),(% style="color:green" %)**5+6+9+10**
875 875  
876 -**AF 03 02 06 0B 02 05 07 08 0A 00**: Same as AT+DATACUT3=**11**,**2**,**5~~7+8~~10**
895 +(% style="color:#037691" %)**AF 03 02 06 **(% style="color:orange" %)**0B**(% style="color:red" %)** 02 **(% style="color:green" %)**05 07 08 0A **(% style="color:#037691" %)**00**(%%): Same as AT+DATACUT3=(% style="color:orange" %)**11**(%%),(% style="color:red" %)**2**(%%),(% style="color:green" %)**5~~7+8~~10**
877 877  
878 878  
879 -0xAB downlink command can be used for set AT+SEARCHx
898 +**0xAB** downlink command can be used for set AT+SEARCHx
880 880  
881 -Example: **AB aa 01 03 xx xx xx** (03 here means there are total 3 bytes after 03) So
900 +**Example:** **AB aa 01 03 xx xx xx** (03 here means there are total 3 bytes after 03) So
882 882  
883 883  * AB aa 01 03 xx xx xx  same as AT+SEARCHaa=1,xx xx xx
884 884  * AB aa 02 03 xx xx xx 02 yy yy(03 means there are 3 bytes after 03, they are xx xx xx;02 means there are 2 bytes after 02, they are yy yy) so the commands
... ... @@ -886,6 +886,7 @@
886 886  **AB aa 02 03 xx xx xx 02 yy yy**  same as **AT+SEARCHaa=2,xx xx xx+yy yy**
887 887  
888 888  
908 +
889 889  ==== Fast command to handle MODBUS device ====
890 890  
891 891  AT+MBFUN is valid since v1.3 firmware version. The command is for fast configure to read Modbus devices. It is only valid for the devices which follow the [[MODBUS-RTU protocol>>url:https://www.modbustools.com/modbus.html]].
... ... @@ -1056,13 +1056,13 @@
1056 1056  
1057 1057  
1058 1058  
1059 -1.
1079 +1.
1060 1060  11. Buttons
1061 1061  
1062 1062  |**Button**|**Feature**
1063 1063  |**RST**|Reboot RS485-BL
1064 1064  
1065 -1.
1085 +1.
1066 1066  11. +3V3 Output
1067 1067  
1068 1068  RS485-BL has a Controllable +3V3 output, user can use this output to power external sensor.
... ... @@ -1080,7 +1080,7 @@
1080 1080  By default, the AT+3V3T=0. This is a special case, means the +3V3 output is always on at any time
1081 1081  
1082 1082  
1083 -1.
1103 +1.
1084 1084  11. +5V Output
1085 1085  
1086 1086  RS485-BL has a Controllable +5V output, user can use this output to power external sensor.
... ... @@ -1100,13 +1100,13 @@
1100 1100  
1101 1101  
1102 1102  
1103 -1.
1123 +1.
1104 1104  11. LEDs
1105 1105  
1106 1106  |**LEDs**|**Feature**
1107 1107  |**LED1**|Blink when device transmit a packet.
1108 1108  
1109 -1.
1129 +1.
1110 1110  11. Switch Jumper
1111 1111  
1112 1112  |**Switch Jumper**|**Feature**
... ... @@ -1152,7 +1152,7 @@
1152 1152  
1153 1153  
1154 1154  
1155 -1.
1175 +1.
1156 1156  11. Common AT Command Sequence
1157 1157  111. Multi-channel ABP mode (Use with SX1301/LG308)
1158 1158  
... ... @@ -1171,8 +1171,8 @@
1171 1171  
1172 1172  ATZ
1173 1173  
1174 -1.
1175 -11.
1194 +1.
1195 +11.
1176 1176  111. Single-channel ABP mode (Use with LG01/LG02)
1177 1177  
1178 1178  AT+FDR   Reset Parameters to Factory Default, Keys Reserve
... ... @@ -1247,7 +1247,7 @@
1247 1247  [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image035.png]] [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image036.png]]
1248 1248  
1249 1249  
1250 -1.
1270 +1.
1251 1251  11. How to change the LoRa Frequency Bands/Region?
1252 1252  
1253 1253  User can follow the introduction for [[how to upgrade image>>path:#upgrade_image]]. When download the images, choose the required image file for download.
... ... @@ -1254,7 +1254,7 @@
1254 1254  
1255 1255  
1256 1256  
1257 -1.
1277 +1.
1258 1258  11. How many RS485-Slave can RS485-BL connects?
1259 1259  
1260 1260  The RS485-BL can support max 32 RS485 devices. Each uplink command of RS485-BL can support max 16 different RS485 command. So RS485-BL can support max 16 RS485 devices pre-program in the device for uplink. For other devices no pre-program, user can use the [[downlink message (type code 0xA8) to poll their info>>path:#downlink_A8]].
... ... @@ -1271,7 +1271,7 @@
1271 1271  
1272 1272  
1273 1273  
1274 -1.
1294 +1.
1275 1275  11. Why I can’t join TTN V3 in US915 /AU915 bands?
1276 1276  
1277 1277  It might about the channels mapping. Please see for detail.