Changes for page RS485-BL – Waterproof RS485 to LoRaWAN Converter
Last modified by Xiaoling on 2025/04/23 15:57
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -751,7 +751,6 @@ 751 751 752 752 === 3.5.2 Sensor related commands: === 753 753 754 -(% class="wikigeneratedid" %) 755 755 ==== ==== 756 756 757 757 ==== **Choose Device Type (RS485 or TTL)** ==== ... ... @@ -760,9 +760,15 @@ 760 760 761 761 * **AT Command** 762 762 762 +(% class="box infomessage" %) 763 +((( 763 763 **AT+MOD=1** ~/~/ Set to support RS485-MODBUS type sensors. User can connect multiply RS485 , Modbus sensors to the A / B pins. 765 +))) 764 764 767 +(% class="box infomessage" %) 768 +((( 765 765 **AT+MOD=2** ~/~/ Set to support TTL Level sensors, User can connect one TTL Sensor to the TXD/RXD/GND pins. 770 +))) 766 766 767 767 768 768 * **Downlink Payload** ... ... @@ -777,7 +777,10 @@ 777 777 778 778 * **AT Command** 779 779 780 -AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m 785 +(% class="box infomessage" %) 786 +((( 787 +**AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m** 788 +))) 781 781 782 782 m: 0: no CRC; 1: add CRC-16/MODBUS in the end of this command. 783 783 ... ... @@ -797,15 +797,15 @@ 797 797 798 798 To connect a Modbus Alarm with below commands. 799 799 800 -* The command to active alarm is: 0A 05 00 04 00 01 4C B0. Where 0A 05 00 04 00 01 is the Modbus command to read the register 00 40 where stored the DI status. The 4C B0 is the CRC-16/MODBUS which calculate manually. 808 +* The command to active alarm is: 0A 05 00 04 00 01 **4C B0**. Where 0A 05 00 04 00 01 is the Modbus command to read the register 00 40 where stored the DI status. The 4C B0 is the CRC-16/MODBUS which calculate manually. 801 801 802 -* The command to deactivate alarm is: 0A 05 00 04 00 00 8D 70. Where 0A 05 00 04 00 00 is the Modbus command to read the register 00 40 where stored the DI status. The 8D 70 is the CRC-16/MODBUS which calculate manually. 810 +* The command to deactivate alarm is: 0A 05 00 04 00 00 **8D 70**. Where 0A 05 00 04 00 00 is the Modbus command to read the register 00 40 where stored the DI status. The 8D 70 is the CRC-16/MODBUS which calculate manually. 803 803 804 804 So if user want to use downlink command to control to RS485 Alarm, he can use: 805 805 806 -**A8 01 06 0A 05 00 04 00 01 00**: to activate the RS485 Alarm 814 +(% style="color:#037691" %)**A8 01 06 0A 05 00 04 00 01 00**(%%): to activate the RS485 Alarm 807 807 808 -**A8 01 06 0A 05 00 04 00 00 00**: to deactivate the RS485 Alarm 816 +(% style="color:#037691" %)**A8 01 06 0A 05 00 04 00 00 00**(%%): to deactivate the RS485 Alarm 809 809 810 810 A8 is type code and 01 means add CRC-16/MODBUS at the end, the 3^^rd^^ byte is 06, means the next 6 bytes are the command to be sent to the RS485 network, the final byte 00 means this command don’t need to acquire output. 811 811 ... ... @@ -814,32 +814,35 @@ 814 814 815 815 Check TTL Sensor return: 816 816 817 -[[image: file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image024.png]]825 +[[image:1654132684752-193.png]] 818 818 819 819 820 820 829 +==== **Set Payload version** ==== 821 821 822 -==== Set Payload version ==== 823 - 824 824 This is the first byte of the uplink payload. RS485-BL can connect to different sensors. User can set the PAYVER field to tell server how to decode the current payload. 825 825 826 -* AT Command: 833 +* **AT Command:** 827 827 828 -AT+PAYVER: Set PAYVER field = 1 835 +(% class="box infomessage" %) 836 +((( 837 +**AT+PAYVER: Set PAYVER field = 1** 838 +))) 829 829 830 830 831 -* Downlink Payload: 841 +* **Downlink Payload:** 832 832 833 -0xAE 01 àSet PAYVER field = 0x01843 +**0xAE 01** ~-~-> Set PAYVER field = 0x01 834 834 835 -0xAE 0F àSet PAYVER field = 0x0F845 +**0xAE 0F** ~-~-> Set PAYVER field = 0x0F 836 836 837 837 838 -==== Set RS485 Sampling Commands ==== 839 839 849 +==== **Set RS485 Sampling Commands** ==== 850 + 840 840 AT+COMMANDx, AT+DATACUTx and AT+SEARCHx 841 841 842 -These three commands are used to configure how the RS485-BL polling data from Modbus device. Detail of usage please see : [[polling RS485 device>> path:#polling_485]].853 +These three commands are used to configure how the RS485-BL polling data from Modbus device. Detail of usage please see : [[polling RS485 device>>||anchor="H3.3.3Configurereadcommandsforeachsampling"]]. 843 843 844 844 845 845 * AT Command:
- 1654132684752-193.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +22.8 KB - Content