Last modified by Xiaoling on 2025/04/23 15:57

From version 29.43
edited by Xiaoling
on 2022/06/02 09:15
Change comment: There is no comment for this version
To version 30.3
edited by Xiaoling
on 2022/06/02 09:22
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -744,6 +744,7 @@
744 744  * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for RS485-BL.  User can see these commands below:
745 745  
746 746  
747 +
747 747  === 3.5.1 Common Commands: ===
748 748  
749 749  They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
... ... @@ -751,7 +751,6 @@
751 751  
752 752  === 3.5.2 Sensor related commands: ===
753 753  
754 -(% class="wikigeneratedid" %)
755 755  ==== ====
756 756  
757 757  ==== **Choose Device Type (RS485 or TTL)** ====
... ... @@ -760,9 +760,15 @@
760 760  
761 761  * **AT Command**
762 762  
763 +(% class="box infomessage" %)
764 +(((
763 763  **AT+MOD=1** ~/~/ Set to support RS485-MODBUS type sensors. User can connect multiply RS485 , Modbus sensors to the A / B pins.
766 +)))
764 764  
768 +(% class="box infomessage" %)
769 +(((
765 765  **AT+MOD=2** ~/~/ Set to support TTL Level sensors, User can connect one TTL Sensor to the TXD/RXD/GND pins.
771 +)))
766 766  
767 767  
768 768  * **Downlink Payload**
... ... @@ -777,7 +777,10 @@
777 777  
778 778  * **AT Command**
779 779  
780 -AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m
786 +(% class="box infomessage" %)
787 +(((
788 +**AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m**
789 +)))
781 781  
782 782  m: 0: no CRC; 1: add CRC-16/MODBUS in the end of this command.
783 783  
... ... @@ -793,19 +793,20 @@
793 793  * XX XX XX XX: RS485 command total NN bytes
794 794  * YY: How many bytes will be uplink from the return of this RS485 command, if YY=0, RS485-BL will execute the downlink command without uplink; if YY>0, RS485-BL will uplink total YY bytes from the output of this RS485 command
795 795  
805 +
796 796  **Example 1:**
797 797  
798 798  To connect a Modbus Alarm with below commands.
799 799  
800 -* The command to active alarm is: 0A 05 00 04 00 01 4C B0. Where 0A 05 00 04 00 01 is the Modbus command to read the register 00 40 where stored the DI status. The 4C B0 is the CRC-16/MODBUS which calculate manually.
810 +* The command to active alarm is: 0A 05 00 04 00 01 **4C B0**. Where 0A 05 00 04 00 01 is the Modbus command to read the register 00 40 where stored the DI status. The 4C B0 is the CRC-16/MODBUS which calculate manually.
801 801  
802 -* The command to deactivate alarm is: 0A 05 00 04 00 00 8D 70. Where 0A 05 00 04 00 00 is the Modbus command to read the register 00 40 where stored the DI status. The 8D 70 is the CRC-16/MODBUS which calculate manually.
812 +* The command to deactivate alarm is: 0A 05 00 04 00 00 **8D 70**. Where 0A 05 00 04 00 00 is the Modbus command to read the register 00 40 where stored the DI status. The 8D 70 is the CRC-16/MODBUS which calculate manually.
803 803  
804 804  So if user want to use downlink command to control to RS485 Alarm, he can use:
805 805  
806 -**A8 01 06 0A 05 00 04 00 01 00**: to activate the RS485 Alarm
816 +(% style="color:#037691" %)**A8 01 06 0A 05 00 04 00 01 00**(%%): to activate the RS485 Alarm
807 807  
808 -**A8 01 06 0A 05 00 04 00 00 00**: to deactivate the RS485 Alarm
818 +(% style="color:#037691" %)**A8 01 06 0A 05 00 04 00 00 00**(%%): to deactivate the RS485 Alarm
809 809  
810 810  A8 is type code and 01 means add CRC-16/MODBUS at the end, the 3^^rd^^ byte is 06, means the next 6 bytes are the command to be sent to the RS485 network, the final byte 00 means this command don’t need to acquire output.
811 811  
... ... @@ -814,25 +814,27 @@
814 814  
815 815  Check TTL Sensor return:
816 816  
817 -[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image024.png]]
827 +[[image:1654132684752-193.png]]
818 818  
819 819  
820 820  
831 +==== **Set Payload version** ====
821 821  
822 -==== Set Payload version ====
823 -
824 824  This is the first byte of the uplink payload. RS485-BL can connect to different sensors. User can set the PAYVER field to tell server how to decode the current payload.
825 825  
826 -* AT Command:
835 +* **AT Command:**
827 827  
828 -AT+PAYVER: Set PAYVER field = 1
837 +(% class="box infomessage" %)
838 +(((
839 +**AT+PAYVER: Set PAYVER field = 1**
840 +)))
829 829  
830 830  
831 -* Downlink Payload:
843 +* **Downlink Payload:**
832 832  
833 -0xAE 01   à Set PAYVER field =  0x01
845 +0xAE 01  ~-~-> Set PAYVER field =  0x01
834 834  
835 -0xAE 0F   à Set PAYVER field =  0x0F
847 +0xAE 0F   ~-~-> Set PAYVER field =  0x0F
836 836  
837 837  
838 838  ==== Set RS485 Sampling Commands ====
... ... @@ -1056,13 +1056,13 @@
1056 1056  
1057 1057  
1058 1058  
1059 -1.
1071 +1.
1060 1060  11. Buttons
1061 1061  
1062 1062  |**Button**|**Feature**
1063 1063  |**RST**|Reboot RS485-BL
1064 1064  
1065 -1.
1077 +1.
1066 1066  11. +3V3 Output
1067 1067  
1068 1068  RS485-BL has a Controllable +3V3 output, user can use this output to power external sensor.
... ... @@ -1080,7 +1080,7 @@
1080 1080  By default, the AT+3V3T=0. This is a special case, means the +3V3 output is always on at any time
1081 1081  
1082 1082  
1083 -1.
1095 +1.
1084 1084  11. +5V Output
1085 1085  
1086 1086  RS485-BL has a Controllable +5V output, user can use this output to power external sensor.
... ... @@ -1100,13 +1100,13 @@
1100 1100  
1101 1101  
1102 1102  
1103 -1.
1115 +1.
1104 1104  11. LEDs
1105 1105  
1106 1106  |**LEDs**|**Feature**
1107 1107  |**LED1**|Blink when device transmit a packet.
1108 1108  
1109 -1.
1121 +1.
1110 1110  11. Switch Jumper
1111 1111  
1112 1112  |**Switch Jumper**|**Feature**
... ... @@ -1152,7 +1152,7 @@
1152 1152  
1153 1153  
1154 1154  
1155 -1.
1167 +1.
1156 1156  11. Common AT Command Sequence
1157 1157  111. Multi-channel ABP mode (Use with SX1301/LG308)
1158 1158  
... ... @@ -1171,8 +1171,8 @@
1171 1171  
1172 1172  ATZ
1173 1173  
1174 -1.
1175 -11.
1186 +1.
1187 +11.
1176 1176  111. Single-channel ABP mode (Use with LG01/LG02)
1177 1177  
1178 1178  AT+FDR   Reset Parameters to Factory Default, Keys Reserve
... ... @@ -1247,7 +1247,7 @@
1247 1247  [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image035.png]] [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image036.png]]
1248 1248  
1249 1249  
1250 -1.
1262 +1.
1251 1251  11. How to change the LoRa Frequency Bands/Region?
1252 1252  
1253 1253  User can follow the introduction for [[how to upgrade image>>path:#upgrade_image]]. When download the images, choose the required image file for download.
... ... @@ -1254,7 +1254,7 @@
1254 1254  
1255 1255  
1256 1256  
1257 -1.
1269 +1.
1258 1258  11. How many RS485-Slave can RS485-BL connects?
1259 1259  
1260 1260  The RS485-BL can support max 32 RS485 devices. Each uplink command of RS485-BL can support max 16 different RS485 command. So RS485-BL can support max 16 RS485 devices pre-program in the device for uplink. For other devices no pre-program, user can use the [[downlink message (type code 0xA8) to poll their info>>path:#downlink_A8]].
... ... @@ -1271,7 +1271,7 @@
1271 1271  
1272 1272  
1273 1273  
1274 -1.
1286 +1.
1275 1275  11. Why I can’t join TTN V3 in US915 /AU915 bands?
1276 1276  
1277 1277  It might about the channels mapping. Please see for detail.
1654132684752-193.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +22.8 KB
Content